X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-089-23185

Well Details

Well ID: 34-089-23185
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: Perry Township
Operator Name: MORAN RONALD F
Well Pad ID:
Farm/Lease Name: WHEELER JERRY
License Status: Producing
License Date: 1987-03-19
Spud Date: 1975-06-10
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1975-07-30
Well Total Depth: 2906.00 ft
Configuration: Vertical
Latitude: 40.100000
Longitude: -82.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1802-01-01
Original Spud 1975-06-10
CO 1975-07-30 407 NETHERS DRILL & LEASING GeoDate 3/19/87
Completed 1975-07-30
Reached Total Depth 1975-07-30
Unknown 1987-03-19 Issued Date 3/19/87 Expired Date 3/18/88 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1988-03-18
Completion Report Received 1994-12-07
CO 1994-12-21 407 NETHERS DRILL & LEASING
CO 1994-12-21 565 MORAN RONALD F GeoDate 3/19/87
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2858 2906 0
2858 2906 0
2858 2906 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 30000 FRAC'D

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 MORAN RONALD F 488.00 583.00 365
1988 MORAN RONALD F 1065.00 664.00 365
1989 MORAN RONALD F 1354.00 332.00 365
1990 MORAN RONALD F 918.00 286.00 365
1991 MORAN RONALD F 748.00 239.00 365
1995 MORAN RONALD F 903.00 323.00 0
1996 MORAN RONALD F 796.00 451.00 0
1997 MORAN RONALD F 1498.00 385.00 365
1998 MORAN RONALD F 1067.00 396.00 365
1999 MORAN RONALD F 1575.00 297.00 365
2000 MORAN RONALD F 489.00 279.00 365
2001 MORAN RONALD F 871.00 297.00 365
2002 MORAN RONALD F 699.00 282.00 365
2003 MORAN RONALD F 1617.00 245.00 365
2004 MORAN RONALD F 1549.00 191.00 365
2005 MORAN RONALD F 701.00 242.00 365
2012 MORAN RONALD F 41.00 75.00 366
2013 MORAN RONALD F 26.00 39.00 365
2014 MORAN RONALD F 28.00 49.00 365
2015 MORAN RONALD F 0.00 44.00 365
2016 MORAN RONALD F 0.00 23.00 366
2017 MORAN RONALD F 0.00 47.00 365
2018 MORAN RONALD F 0.00 48.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 MORAN RONALD F Brine 265 365
1988 MORAN RONALD F Brine 925 365
1989 MORAN RONALD F Brine 453 365
1990 MORAN RONALD F Brine 880 365
1991 MORAN RONALD F Brine 574 365
1995 MORAN RONALD F Brine 560 0
1996 MORAN RONALD F Brine 1750 0
1997 MORAN RONALD F Brine 2150 365
1998 MORAN RONALD F Brine 1930 365
1999 MORAN RONALD F Brine 2180 365
2000 MORAN RONALD F Brine 1250 365
2001 MORAN RONALD F Brine 1850 365
2002 MORAN RONALD F Brine 1960 365
2003 MORAN RONALD F Brine 1600 365
2004 MORAN RONALD F Brine 188 365
2005 MORAN RONALD F Brine 2240 365
2012 MORAN RONALD F Brine 1200 366
2013 MORAN RONALD F Brine 703 365
2014 MORAN RONALD F Brine 998 365
2015 MORAN RONALD F Brine 770 365
2016 MORAN RONALD F Brine 566 366
2017 MORAN RONALD F Brine 655 365
2018 MORAN RONALD F Brine 577 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1961128568 2013-5-8 0:00:0 PW No Violations
-338924856 2013-11-18 0:00 PW No Violations
0338924856 2013-11-18 Production Wells No Violations This inspection was conducted as a compliance notice follow-up. Identification has been posted at the wellhead. Violation resolved.
1240847715 2009-04-20 Production Wells No Violations Complaint Doug and Roz Chester. Common tank battery sets on their property above their water well. 2 100 Bbl steel tanks and 2 vertical separators. They have received free gas resulting from tanks setting on their 4 acres. Inside dike surface is clean, except for one place 2 x 2 where appears crude oil blowed from line at drip for house gas. Outside of dike on lower corner shows leaching and kill of vegetation. quantab water well, 3.0 on low range quantab or 111ppm chloride. Ran well for 5 minutes thru 2 pump cycles. Taken at frost free hydrant at water well. (5 casing, GPS N40.10971,W082.24760) Water was very red or rusty colored and had a lot of sediment. Mrs. Chester said that the well does that from time to time. Water well drilled by Stuart Bevard. All tanks have been disconnected at the bottom fittings, lines removed, and plugs put in stops. Well has pump jack and no ID at well. Well is capable and is located on the Jerry Wheeler property or lease. Tanks have ID. Tanks are common tanks for P# 3435, and 5300.
1240849201 2009-04-22 Production Wells No Violations Operator Ron Moran met me at tank battery at my request to review site. Ron said all three wells together dont make enough gas to keep the Chester residence supplied during the winter months, and supply the landowner Mr. Wheeler.All three wells currently areshut in. Ron said Doug Chester is the one who blew the drip with oil at the dike. Mr. Moran said Jerry Wheeler interested in taking over the wells or he might plug them. He will have tanks emptiied by water trucks and wif wells kept will move them onto Mr. Wheelers property. Area also to be properly cleaned up. Ron Moran and I talked to Mr. Jerry Wheeler who wants the gas but not the wells unless the price is right. I explained bonding requirements and with three wells he would not qualify for domestic operator and would need $15,000 bond. He and Ron Moran will have to work out what they need to do. Mr. Wheeler does not get along with Mr. Chester.
1370021516 2013-05-01 Production Wells Violations Noted I inspected the tank battery for this well today. The tank battery is a shared tank battery with the Wheeler #2 (08923435) and Wheeler #3 (08925300). The tank battery battery consists of (2) 100 barrel tanks and a gas separator. A 300 barrel frac tank sits further down hill from the tank battery near the driveway for the Wheeler residence and is used for brine storage. The frac tank did not have a dike. The inspection revealed that the frac tank appeared to have been run over and oil might have entered an intermittent stream. The frac tank had some crude oil on top of the water. The oil flowed down the hill from the tank in a ditch that runs along the driveway. The oil then entered a ditch that runs parallel with Licking Valley Rd. (CR 668) and appears to have entered a stream on the east side of Licking Valley Rd. A pumper, Tim Marshall, for Ronald F. Moran arrived during the inspection. Mr. Marshall informed me that approximately 1-2 barrels of oil made it into the ditch that parallels Licking Valley Rd. The spill ocurred on 4/29/2013 but the company did not notify the DOGRM or the EPA. The pumper informed me that it happened while he was there and that cleanup began immediatley. Straw and peat absorbent was applied to the ditches to absorb oil. The company was informed of their obligation to notify the EPA when a stream and/or ditch is impacted. The company was also informed of their obligation to notify the inspector when there is a spill. The company will monitor the ditches and will need to remove the straw/absorbent material within 1 week.
1423313072 2015-03-17 Production Wells No Violations Inspect tank battery regarding a phone call from Chris Holmes with Ohio EPA at 9:00 AM. Mr. Holmes stated that an anonymous phone call was made to the OEPA about a hose coming from the dike had fluid running out it and down the driveway entering a ditch. The inspection revealed no hose or any evidence of fluid entering a ditch. A phone call was placed to the company inquiring about a hose. The company informed me that over the weekend the dike was full of water due to a large rain event and that they pumped the water out of the dike. Inspection revealed no violations. Time of inspection: 9:50 AM.
1524659987 2018-04-24 Production Wells No Violations A water sample was collected for analysis. The specific gravity was field tested at 1.23 units.
1563646709 2013-07-08 Production Wells Violations Noted This inspection was conducted as part of a standard production well status check. The well was equipped with a pumping unit and motor. It was not pumping during inspection. Identification was not posted at the wellhead. OAC 1501:9-9-05 requires each wellhead to be identified if multiple wells are being produced into a common tank battery.
1961128568 2013-05-08 Production Wells No Violations This inspection was conducted as a follow-up inspection for NOV# 1370021516. Jeff Fry accompanied me on this visit. David Garber, a pumper for Ronald Moran, met us at the tank battery location. I informed Mr. Garber that the straw in the ditches needed to be removed and taken off location. Mr. Garber began cleanup immediately and informed me that it would be finished by the end of the day.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1370021516 US-OH-110921 2013-06-03 Well operation causing pollution and contamination
1370021516 US-OH-110922 2013-06-03 No SPCC dike/or failure to keep dike free of water or oil
1563646709 US-OH-115269 2014-02-13 Failure to legibly identify well

For data sources see[9]

References