X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-087-20468

Well Details

Well ID: 34-087-20468
Loading map...
Country: United States
State: Ohio
County: Lawrence
Municipality: Mason Township
Operator Name: PILLAR ENERGY LLC
Well Pad ID:
Farm/Lease Name: HAMM J
License Status: Active Injection
License Date: 1996-05-22
Spud Date: 1994-07-08
Spud Drilling Contractor: GRIM DRILLING
Final Drill Date: 1994-08-13
Well Total Depth: 715.00 ft
Configuration: Vertical
Latitude: 38.620000
Longitude: -82.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1993-12-20 Issued Date 12/20/93 Expired Date 12/20/94 Acres 0001000 Tool Type CT Proposed Formation COW RUN Proposed Depth 00717 Proposed Drill Depth 00717
Original Spud 1994-07-07 CONVERT 5-25-96
Completed 1994-08-13 CONVERT 5-25-96
Reached Total Depth 1994-08-13 CONVERT 5-25-96
CO 1994-09-06 1089 MITCHELL ENERGY CORP GeoDate 12/20/93
First Injection 1994-09-06 CONVERT 5-25-96
Completion Report Received 1994-10-03 CONVERT 5-25-96
CO 1996-05-22 1089 MITCHELL ENERGY CORP GeoDate 5/22/96
Enhanced Recovery 1996-05-22 Issued Date 5/22/96 Expired Date 5/22/97 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth Proposed Drill Depth
Annulus Pressure Monitoring Approved 1997-02-25 CONVERT 5-25-96
Construction Permit Expires 1997-05-22 CONVERT 5-25-96
Change of Owner 1999-10-22 Operator changed from 1089, MITCHELL ENERGY CORP to 3793, ENERGY SEARCH INC
Last Compliance Report 2000-03-03 CONVERT 5-25-96
Change of Owner 2008-02-26 Operator changed from 3793, ENERGY SEARCH INC to 1388, NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Change of Owner 2016-02-24 Operator changed from 7578, ENERVEST OPERATING LLC to 9619, PILLAR ENERGY LLC
Record Last Modified 2017-02-15 CONVERT 5-25-96

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-03-03 650 670 1
650 670 1
650 670 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 7145 Gal 10260
ACID 0 750 Gal 8 PERFORATED WITH 250 GAL 7.5% FE ACID, 7145 GLS OF 25# GEL, AND 10,260# 20/40 SAND
GEL 0 25 Lbs 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 MITCHELL ENERGY CORP 0.00 389.00 61
1995 MITCHELL ENERGY CORP 0.00 1097.00 360
2008 EXCO - NORTH COAST ENERGY INC 0.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 0.00 0.00 0
2010 ENERVEST OPERATING LLC 0.00 0.00 0
2011 ENERVEST OPERATING LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 MITCHELL ENERGY CORP Brine 74 61
1995 MITCHELL ENERGY CORP Brine 178 360
2008 EXCO - NORTH COAST ENERGY INC Brine 0 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 0
2010 ENERVEST OPERATING LLC Brine 0 0
2011 ENERVEST OPERATING LLC Brine 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1016528814 2013-12-11 0:00 SC No Violations 2.00
-1061690493 2018-6-19 0:00: ER No Violations 0.50
-1145765233 2014-11-20 0:00 ER No Violations 0.50
-1160765306 2013-7-16 0:00: ER No Violations 8.00
-1178352060 2006-1-24 0:00: ER No Violations
-1182299253 2007-9-25 0:00: ER No Violations
-1205129970 2007-5-31 0:00: ER No Violations
-1258841576155175 2004-3-4 0:00:0 SW No Violations
-1271394879150245 2004-10-29 0:00 PL No Violations
-1271394879155176 2004-10-29 0:00 SW No Violations
-1418602637 2013-9-5 0:00:0 ER No Violations 0.50
-1545034222 2020-4-7 0:00:0 ER No Violations 1.00
-1604871931 2005-2-9 0:00:0 SW No Violations
-1638763740 2008-9-25 0:00: ER No Violations
-1677286535 2010-9-13 0:00: ER No Violations 0.50
-1701646012 2013-3-14 0:00: ER No Violations 2.50
-1725198861 2010-3-9 0:00:0 ER No Violations
-1756416167 2004-8-3 0:00:0 SW No Violations
-1795683853 2011-12-9 0:00: ER No Violations 0.30
-1826740116 2011-4-6 0:00:0 ER No Violations
-1843277813 2014-6-20 0:00: ER No Violations 1.00
-1855093018 2006-3-20 0:00: ER No Violations
-185676870 2009-2-26 0:00: ER No Violations
-1877617662 2012-10-3 0:00: ER No Violations 0.50
-199894479 2013-1-7 0:00:0 SC No Violations 2.50
-2010794460 2009-5-12 0:00: ER No Violations
-326252546 2015-6-23 0:00: SW No Violations 0.50
-391244377 2015-10-13 0:00 ER No Violations 1.00
-415632221 2005-11-10 0:00 ER No Violations
-440122429 2019-2-19 0:00: ER No Violations 1.00
-545302820 2013-1-9 0:00:0 ER No Violations 0.70
-627473858 2020-7-14 0:00: ER No Violations 0.50
-630184246 2004-3-2 0:00:0 PW No Violations
-684136684 2012-10-3 0:00: ER No Violations 0.50
-705100899 2003-3-27 0:00: ER No Violations 0.00
-808272739 2013-10-21 0:00 ER No Violations 0.50
001269i767 2002-02-13 Enhanced Recovery Project No Violations Follow-up on NOV, In-Compliance.
0036322920 2008-01-16 Enhanced Recovery Project No Violations Pressure regulators made by Jordan Valves have been installed and are working great. The valves have a max. back pressure of 400psi, and a max. working pressure of 600psi. They are being set slightly below max. injection pressures.
0053971889 2014-02-13 Enhanced Recovery Project No Violations Bimonthly inspection of ERP field injection wells performed by me and Jon Scott. There are no noticeable leaks in plumbing at wellhead. Identification sign and wellhead in good shape.
0089862158 2004-05-21 Salt Water Injection Well No Violations Recheck of annulus pressure - Ok today. Will continue to monitor due to abnormally high reading on 5/20/04.
0125545414 2009-11-17 Enhanced Recovery Project No Violations Good Identification. No violations observed during inspection.
0136768932 2006-11-21 Enhanced Recovery Project Violations Noted Exceded Maximum Injection pressure
0185676870 2009-02-26 Enhanced Recovery Project No Violations Good id. No violations observed during inspection.
0199894479 2013-01-07 Surface Facility Construction No Violations Concrete dike pad has been poured. Concrete block and mortar is on site. Extended concrete apron to unloading pad.
0200295864 2010-03-19 Enhanced Recovery Project No Violations Filter housing leak has been repaired.
0326252546 2015-06-23 Salt Water Injection Well No Violations No noted violations.
0327837549 2004-05-20 Salt Water Injection Well No Violations Within allowable tubing limit. Abnormal reading on the annulus.
0387464538 2017-06-28 Salt Water Injection Well No Violations Salt water injection well inspection. The annulus pressure was 22 psi, the injection tubing pressure was 47 psi. No violations were noted during my inspection.
0391244377 2015-10-13 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, unloading pad, injection pump, injection pressure, and annulus pressure. Identification posted at the well.
0413888724 2005-04-28 Enhanced Recovery Project No Violations Annulus pressure abnormally high
0415632221 2005-11-10 Enhanced Recovery Project No Violations Ok.
0440122429 2019-02-19 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
0516849153 2006-08-15 Enhanced Recovery Project No Violations Within limits.
0534269118 2004-10-29 Salt Water Injection Well No Violations Within specifications.
0545302820 2013-01-09 Enhanced Recovery Project No Violations Accompanied Jon Scott to this injection well to perform bimonthly inspection and measure its annulus pressure and actual injection pressure.
0567722589 2008-03-25 Enhanced Recovery Project No Violations No violations were observed. The new pressure regulator is working well.
0630184246 2004-03-02 Production Wells No Violations No problems observed.
0640712778 2011-01-05 Enhanced Recovery Project No Violations Brine leak coning from the 1 by 3/4 bushing and close 3/4 nipple between the filter housing and the pressure regulator. I talked to Bo Pinkerman and he told me it will be fixed today.
0648886259 2010-06-18 Enhanced Recovery Project No Violations Well id for Exco-North Coast, Needs to have Enervest information and contact phone numbers. I have talked to Jim Ross (Enervest contractor) about this needing to be changed as soon as possible.
0684136684 2012-10-03 Enhanced Recovery Project No Violations Inspected injection pressure and annulus pressure. Good identification on wellhead.
0692550779 2016-03-29 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification has not been changed from Enervest to Pillar Energy.
0705100899 2003-03-27 Enhanced Recovery Project Violations Noted During an inspection of the site, the injection pressure was measured at 232 psi. The maximum allowable injection pressure is 206 psi.

The injection pressure must be lowered by at least 26 psi.

0755499953 2014-08-19 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, walked the injection line, checked the injection pressure and annulus pressure. Good identification at wellhead.
0770756534 2003-06-19 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # 1178966269 The injection pressure measured was 229 psi, which exceeds the maximum allowable injection pressure of 206 psi.

On June 19, 2003, Tim Ross was informed of the violation and advised to immediately decrease the injection pressure below 206 psi.

0808272739 2013-10-21 Enhanced Recovery Project No Violations Inspected the injection wells in this ERP field with Jon Scott. The sign and wellhead for this well are in good shape. No leaks were detected at this time. Flow meter for this well indicated 42.45 bbls total but also reported 0 bbls per day.
0853050331 2018-03-19 Salt Water Injection Well No Violations I was on location today to check the pressures of this salt water injection well. The annulus pressure was 58 psi, the injection tubing pressure was 19 psi. No violations were noted during my inspection.
0966747216 2016-01-07 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well.
0977601338 2004-09-02 Salt Water Injection Well No Violations Checked annulus pressure - had a problem earlier.
0978415693 2016-06-08 Enhanced Recovery Project No Violations Inspected the injection pressure, annulus pressure, unloading pad, containment dike, tanks, and injection pump. Ezra Schoolcraft and Bo Pinkerman are in the ERP field replacing identifications on the wells today. I talked to Ezra about the need to grade the access roads to prevent erosion. We discussed the need for controlling the runoff with diversion ditches and water bars.
0983830754 2005-09-14 Enhanced Recovery Project No Violations OK
0994771919 2003-05-15 Enhanced Recovery Project No Violations Injection pressure is below the maximum. Well is in compliance.
1016528814 2013-12-11 Surface Facility Construction No Violations Inspected the changes that have been made to the pump house injection line manifolds and the change over to a different injection pump. Inspected the unloading pad, containment dike and tanks.
1061690493 2018-06-19 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted at the well. The containment dike is free of fluids.
1066231376 2003-10-08 Enhanced Recovery Project No Violations No violations at the time of inspection.
1145765233 2014-11-20 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Good identification at well site. Injection line has been disconnected from injection line. Waiting on service rig to replace top joint of injection tubing.
1160765306 2013-07-16 Enhanced Recovery Project No Violations Contractor repaired the monitoring tubing used to measure the annular pressure of this injection well. No further action necessary at this time.
1178352060 2006-01-24 Enhanced Recovery Project No Violations Pressures below maximum allowable; couldnt measure annulus pressure because valve cannot be opened with gauge on opening. Requested that the set-up be modified so that the annulus can be turned on with the gauge in place.
1178966269 2003-06-19 Enhanced Recovery Project Violations Noted The injection pressure measured was 229 psi, which exceeds the maximum allowable injection pressure of 206 psi.

On June 19, 2003, Tim Ross was informed of the violation and advised to immediately decrease the injection pressure below 206 psi.

1182299253 2007-09-25 Enhanced Recovery Project No Violations No violations at this time.
1205129970 2007-05-31 Enhanced Recovery Project No Violations No violations at this time.
1210468780 2013-07-15 Enhanced Recovery Project No Violations Bimonthly UIC monitoring of Greasy Ridge ERP injection wells with Jon Scott. Wellhead and well identification sign are in good shape. Annular monitoring tubing is loose on the fitting attached to the t-fitting on the wellhead. There is apparently no brine leak at this fitting but I contacted the operator of the field to tighten the fitting. I will follow-up on this issue to determine if repair has been implemented.
125545414 2009-11-17 0:00 ER No Violations
1258841576 2004-03-04 Salt Water Injection Well No Violations Within the specified range
1269i767 2002-2-13 0:00: ER No Violations
1271394879 2004-10-29 Preliminary Restoration No Violations Passed.
1345649887 2008-07-17 Enhanced Recovery Project No Violations Good Identification. No violations at this time.
136768932 2006-11-21 0:00 ER No Violations
1401253814 2007-02-23 Enhanced Recovery Project No Violations Passed mini test. No problems at this time.
1418602637 2013-09-05 Enhanced Recovery Project No Violations Jon Scott and I performed the bimonthly UIC inspection on the injection wells in this field. There were no leaks and the identification sign was in good shape.
1527668998 2009-08-17 Enhanced Recovery Project No Violations Good identification. No violations observed during inspection.
1604871931 2005-02-09 Salt Water Injection Well No Violations Within limits.
1606075497 2019-6-12 0:00: ER No Violations 1.00
1620339781 2016-11-09 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, unloading pad, injection pumps, injection pressure and annulus pressure. Identification posted at the well. The containment dike is free of fluids.
1637367321 2019-10-21 0:00 ER No Violations 2.00
1638763740 2008-09-25 Enhanced Recovery Project No Violations Good id. No violations at this time.
1677286535 2010-09-13 Enhanced Recovery Project No Violations Good identification. No violations observed.
1701646012 2013-03-14 Enhanced Recovery Project No Violations Jon Scott and I conducted the bimonthly inspection for this ERP field. We split up to cover more ground and try to complete this inspection in a timely manor. Wellhead identification sign is in good shape. Pipe and wellhead wrapped with silver coated insulation.
1722282528 2019-9-13 0:00: ER No Violations 0.70
1725198861 2010-03-09 Enhanced Recovery Project No Violations Good identification. Filter housing dripping brine. I told Jim Ross about the leak. Jim sent the pumper out to repair leak. Repair filter brine leak.
1756416167 2004-08-03 Salt Water Injection Well No Violations No violations
1772410504 2013-05-03 Enhanced Recovery Project No Violations Inspected injection well and measured injection pressure and annulus pressure. Well in good shape. Well identification in good shape.
1783171331 2011-01-06 Enhanced Recovery Project No Violations Brine leak has been fixed.
1795683853 2011-12-09 Enhanced Recovery Project No Violations Accompanied Jon Scott for ERP training. Site clean, not exceeding max injection.
1826740116 2011-04-06 Enhanced Recovery Project No Violations No violations at this time.
1843277813 2014-06-20 Enhanced Recovery Project No Violations Inspected injection pressure, annulus pressure and walked the pipe line right of way. Good identification at the well. I talked to Jim Ross about the need to replace the 1/4 90 ell on the annulus due to corroded threads. Jim agreed to change the fitting.
1855093018 2006-03-20 Enhanced Recovery Project No Violations Within limits
1864889369 2015-04-22 Enhanced Recovery Project No Violations No noted violations.
1877617662 2012-10-03 Enhanced Recovery Project No Violations Inspected wells with Jon Scott. Measured Injection and Annulus pressure for wells in this field. Well ID was good.
1879416821 2007-04-04 Enhanced Recovery Project No Violations No problems, Jim Ross has grated the lease roads.
1923859254 2013-01-09 Enhanced Recovery Project No Violations Inspected enhanced recovery well injection tubing pressure and annulus pressure. Good identification at well head. Accompanied by Morgan Button MRI 2.
1972665583 2012-04-05 Enhanced Recovery Project No Violations No violations at the time of inspection. One of the gate valves had a slight leak.
200295864 2010-3-19 0:00: ER No Violations
2009885466 2018-10-22 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
2010794460 2009-05-12 Enhanced Recovery Project No Violations Good id. No violations were observed at time of inspection.
2050560844 2011-08-02 Enhanced Recovery Project No Violations Good identification. No violations observed during inspection.
2050990796 2016-08-19 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well.
2076571680 2018-09-14 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pumps, injection pressure and annulus pressure. Identification is posted at the well. The containment dike is free of fluids.
2103420447 2004-10-29 Preliminary Restoration No Violations Passed
2120725944 2008-06-12 Enhanced Recovery Project No Violations No violations at this time.
327837549 2004-5-20 0:00: SW No Violations
36322920 2008-1-16 0:00: ER No Violations
380061856 2020-1-30 0:00: ER No Violations 1.00
387464538 2017-6-28 0:00: SW No Violations 1.00
413888724 2005-4-28 0:00: ER No Violations
516849153 2006-8-15 0:00: ER No Violations
534269118 2004-10-29 0:00 SW No Violations
53971889 2014-2-13 0:00: ER No Violations 0.50
567722589 2008-3-25 0:00: ER No Violations
640712778 2011-1-5 0:00:0 ER No Violations
648886259 2010-6-18 0:00: ER No Violations
692550779 2016-3-29 0:00: ER No Violations 0.70
755499953 2014-8-19 0:00: ER No Violations 1.50
770756534 2003-6-19 0:00: ER No Violations
853050331 2018-3-19 0:00: SW No Violations 0.30
870337624 2020-6-17 0:00: ER No Violations 0.50
89862158 2004-5-21 0:00: SW No Violations
966747216 2016-1-7 0:00:0 ER No Violations 2.00
977601338 2004-9-2 0:00:0 SW No Violations
978415693 2016-6-8 0:00:0 ER No Violations 1.00
983830754 2005-9-14 0:00: ER No Violations
994771919 2003-5-15 0:00: ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0136768932 US-OH-110839 2006-11-27 Exceeding maximum allowable injection pressure
0705100899 US-OH-127962 2003-03-31 Exceeding maximum allowable injection pressure
0770756534 US-OH-128757 2003-06-23 Exceeding maximum allowable injection pressure
1178966269 US-OH-104767 2003-06-23 Exceeding maximum allowable injection pressure

For data sources see[9]

References