34-085-21279

Well Details

Well ID: 34-085-21279
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: THIRION
License Status: Producing
License Date: 2008-05-13
Spud Date: 2008-10-05
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-10-13
Well Total Depth: 3679.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -81.230000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-05-13 Proposed Formations:CLINTON, Issued Date:5/13/2008, Expired Date:5/13/2009 6:00:00 AM, Drilling unit acres:20.16, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-13
Completion Report Received 2008-12-10
Construction Permit Expires 2009-05-13
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-01-20 3464 3475 22
3464 3475 22
3464 3475 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 521 Mscf 100000 FRAC ALSO INVOLVED 17,529 GAL WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY 262.00 0.00 35
2009 JOHN D OIL & GAS COMPANY 3334.00 59.00 365
2010 JOHN D OIL & GAS COMPANY 2697.00 26.00 365
2011 JOHN D OIL & GAS COMPANY 2353.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 1900.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 975.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 571.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 458.00 0.00 365
2016 DAVID OIL COMPANY LLC 156.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY Brine 0 35
2009 JOHN D OIL & GAS COMPANY Brine 320 365
2010 JOHN D OIL & GAS COMPANY Brine 380 365
2011 JOHN D OIL & GAS COMPANY Brine 320 365
2012 JOHN D OIL & GAS COMPANY Brine 80 366
2013 JOHN D OIL & GAS COMPANY Brine 160 365
2014 JOHN D OIL & GAS COMPANY Brine 190 365
2015 JOHN D OIL & GAS COMPANY Brine 80 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1438451628 2008-10-14 0:00 DD No Violations
-1448405773 2019-6-18 0:00: UP No Violations
-1452808560 2017-9-25 0:00: UP No Violations 0.50
-1601432331 2017-12-5 0:00: UP No Violations 0.50
-64418203 2016-2-9 0:00:0 UP No Violations 0.50
-938493439 2018-2-13 0:00: UP No Violations 0.50
0064418203 2016-02-09 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and associated battery are located behind the single-family house at this location. The well and battery are accessed via a short, unpaved road that extends to the east beyond the house driveway for 200 feet. At the time of this inspection, I observed the following: a wellhead with gasoline-fired pump jack system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank and separator in a separate board-on-board enclosure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present but not visible on the outside of the battery. I noted the following safety issues: The load-line valves were not locked and enclosure gates were unlocked. The owner must remedy the following by 04/08/2016: secure the load-line valves with locks, secure the enclosures with locks. Place proper ID in a conspicuous location on the outside of the battery. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0163924995 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located in a open, grassy portion on a residential property in an area of mostly sparse residential development. The well is comprised of a mechanical pump-jack system in a board-on-board enclosure which is locked. Fittings and connections at the wellhead are secure. The battery is comprised of one 210-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings and connections are secure. The secondary containment is intact and dry. Load-outs are secure. The areas surrounding the well and battery consist mainly of turf grass and woods. I did not observe any signs of impact or drainage problems at the time of this inspection.
0388314124 2017-04-10 UrbanProduction Wells No Violations I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a gravel-paved road that enters from Orchard Road and travels 700 feet to the well and battery, was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured, the ID signage had not been updated to reflect the recent change in ownership, and the wellhead enclosure has been partially dismantled.
0938493439 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
1382551236 2013-10-23 UrbanProduction Wells No Violations The producing unit consists of a pump jack unit and above-ground storage tank (AST) battery. The battery is comprised of 1 210-barrel steel production tank and 1 100-barrel brine tank, and separator unit. The wellhead and battery are both in separate board-on-board enclosures. The load-outs are bull-plugged. The ID and secondary containment are good. Spark arrestor, carbon filter, and low-pressure relief valve are present. No problems noted.
1438451628 2008-10-14 Drill / Deepen / Reopen No Violations cementing 4.5
1452808560 2017-09-25 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and ID not posted in a visible location. At the time of this inspection, the noted deficiency remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
1601432331 2017-12-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. At the time of this inspection, I observed the following: there were no locks at the load-line valves, the battery enclosure gate was not locked and left open. In addition, the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
163924995 2015-4-22 0:00: UP No Violations 0.50
1950863681 2009-08-31 Preliminary Restoration No Violations Preliminary restoration meets the requirements of 1509.072 ORC.
2004017635 2018-04-17 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
388314124 2017-4-10 0:00: UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0064418203 US-OH-127299 2016-04-27 ID (a-i)
0064418203 US-OH-127300 2016-04-27 LOCKS

For data sources see[9]