X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21278

Well Details

Well ID: 34-085-21278
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Leroy Township
Operator Name: OSAIR INC
Well Pad ID:
Farm/Lease Name: DICKEY
License Status: Producing
License Date: 2011-10-13
Spud Date: 2009-01-28
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2009-02-11
Well Total Depth: 6310.00 ft
Configuration: Vertical
Latitude: 41.710000
Longitude: -81.170000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-05-07 Proposed Formations:TRENTON/BLACK RIVER, Issued Date:5/7/2008, Expired Date:5/7/2009 6:00:00 AM, Drilling unit acres:41, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2008-08-29 CORRECTION TO CASING PROGRAM, CHANGED PROPOSED TOTAL DEPTH (NOW 6300'), CHANGED PROPOSED GEOLOGICAL FORMATION (NOW TRENTON THROUGH PRE CAMBRIAN), ADDED ADDITIONAL PERMIT CONDITIONS.
Reached Total Depth 2009-02-11 BECAUSE WELL WAS NEVER CONVERTED I REMOVED TYPE OF ISWD TO OG AND REMOVED SWIW #7 FROM WELL NAME.
Completion Report Received 2010-10-12 BECAUSE WELL WAS NEVER CONVERTED I REMOVED TYPE OF ISWD TO OG AND REMOVED SWIW #7 FROM WELL NAME.
Annulus Pressure Monitoring Approved 2011-10-13 BECAUSE WELL WAS NEVER CONVERTED I REMOVED TYPE OF ISWD TO OG AND REMOVED SWIW #7 FROM WELL NAME.
APP 2011-10-13 Proposed Formations:MT.SIMON SANDSTONE, Issued Date:10/13/2011, Expired Date:10/12/2013 12:00:00 PM, Drilling unit acres:41, Proposed Well Type:SWD, Proposed Well Class:SWIW
Change of Owner 2012-02-08 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 957, OSAIR INC
Construction Permit Expires 2013-10-12 BECAUSE WELL WAS NEVER CONVERTED I REMOVED TYPE OF ISWD TO OG AND REMOVED SWIW #7 FROM WELL NAME.
Change of Owner 2013-12-23 Operator changed from 957, OSAIR INC to 9215, OSAIR INC
Record Last Modified 2017-10-24 BECAUSE WELL WAS NEVER CONVERTED I REMOVED TYPE OF ISWD TO OG AND REMOVED SWIW #7 FROM WELL NAME.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-08-11 3140 3179 21
2010-10-12 5584 5590 28
5584 5590 28
3140 3179 21
3140 3179 21

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1200 Gal 0
H2O 0 16780 Gal 100000
H2O 0 197 Bbl 20000 AFTER FRAC IP INCREASED FROM 2 MCFD TO 5 MCFD

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 GREAT PLAINS EXPLORATION LLC 0.00 0.00 102
2011 GREAT PLAINS EXPLORATION LLC 1839.00 42.00 185
2012 GREAT PLAINS EXPLORATION LLC 1253.00 0.00 185
2013 OSAIR INC 211.00 0.00 185
2014 OSAIR INC 255.00 0.00 185
2015 GREAT PLAINS EXPLORATION LLC 40.00 0.00 365
2016 OSAIR INC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 GREAT PLAINS EXPLORATION LLC Brine 0 102
2011 GREAT PLAINS EXPLORATION LLC Brine 1920 185
2012 GREAT PLAINS EXPLORATION LLC Brine 1120 185
2013 OSAIR INC Brine 240 185
2014 OSAIR INC Brine 0 185
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1705689755 2018-4-17 0:00: UP No Violations 0.50
-383529736 2020-4-20 0:00: PW No Violations
-415062245 2017-12-6 0:00: UP No Violations 0.50
-418664365 2019-8-22 0:00: PW No Violations
-786442178 2011-11-8 0:00: PW No Violations
-838758651 2017-9-7 0:00:0 UP No Violations 0.50
-981811984 2019-3-26 0:00: PW No Violations
0314750578 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiency: No current and accurate ID. At the time of this inspection, I observed the following: The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies
0415062245 2017-12-06 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. The well and battery are located on a larger rural parcel. Fittings and connections at the wellhead and battery were secure and free from leakage. The well was not in active production at the time of this inspection. The unit identification had not been updated to reflect the new ownership which took effect in 2012. The owner must place compliant unit identification at the well within 30 days or be subject to additional enforcement. Contact Inspector Stephen Tompkins at 330-907-4647 with questions about this compliance notice.
0786442178 2011-11-08 Production Wells No Violations This is a pump jack well. Lease road is stable. Erosion is controled. Tank battery is in good repair.
0838758651 2017-09-07 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated battery are located on a larger, rural parcel. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery. The various fittings and connections were secure and free from leakage or problems. The secondary containment was intact and dry. The tank lids were closed and secure. I walked the areas surrounding the wellhead and battery and observed no signs of impact to the natural greenscape.
0909832296 2009-01-29 Drill / Deepen / Reopen Violations Noted Drill depth 14, drilling on fluid. Pit liners were in good repair. It was noted during inspection that 2/3 of the pit was red. Operator had winterized pumps with off-road (#2) diesel fuel, 10 gallons. Fuel was in the pits floating on the ice and water. This was the fresh water pit, same fluid operator was using to drill CND hole. Operator was order to shut down and remove #2 diesel fuel from the pit. James and Jon, called in a brine truck to pump fuel from pit. Jon left site to pick up boom, for around the mud pump intake. Operator was able to remove majority of the fuel from the pits, boom will be sufficient to prevent fuel from going into intake. Called Tim Reiley Great Plains, on 01/30/2009, informed Tim that it was not acceptable to have any contaminates in the fresh water pits especially diesel fuel. Reminded Tim, that a small amount of fuel can contaminate thousands of gallons of fresh water. If any water wells are contaminated the company will be responsible to immediately replace water supplies. The company was drilling in the Ohio Shale at the time. Immediately shut down and clean off-road diesel fuel from the fresh water pit. Install boom around mud pump intake to prevent any residual fuel from contaminate fresh water intake.
0981811984 2019-03-26 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice # 415062245, regarding the installation of identification needing current owner information. At the time of this inspection, the identification has not been updated to reflect current owner information. The well was not in production, at the time of this inspection.
1233582189 2009-01-30 Drill / Deepen / Reopen No Violations Cementing 85/8 casing good returns.
1281366968 2016-01-26 Production Wells No Violations I inspected this producing well as part of routine inspection activity. Access to the wellhead and battery are afforded by a shared-use driveway. At the time of this inspection, I observed the following: A wellhead with pump jack system and tank battery with one steel 100-barrel production tank, one FRP 100-barrel brine tank, separator and metering run. I observed the back-pressure valve at the wellhead to be leaking gas. The remainder of the connections and fittings were secure and free from leakage. The secondary containment was intact and free from standing fluids, staining, or other signs of leakage. The load-puts were bull-plugged and secure. The access road was in good condition. I notified the well owner about the leaking fitting and they indicated it would be addressed wihtin the next 2 days.
1325169047 2011-12-27 Salt Water Injection Well No Violations Pop-off on the separator was discharging gas. Annulus on the well was static and there was minor gas bubbling on the outside of the 8.625 casing. The cables are off of the pumping unit. This well has not been converted to an injection well at this time. I called Jim from John D and left a message that there was gas leaking from the top of the separator.
1376498253 2013-08-14 UrbanProduction Wells No Violations The producing unit consists of a wellhead with pumpjack and aboveground storage tank battery. The elements of the unit are not enclosed. The battery is comprised of one 100-barrel production and 1 100-barrel brine tank, and a separator unit. There is adequate secondary containment capacity and appropriate ID placard. The unit spacing requirements are met. The gas leakage observed previously at the separator and the wellhead was not observed at this time. No other problems or issues noted.
1612913282 2014-10-29 Production Wells No Violations I inspected this location has part of routine inspection activity. The well is producing and production records are current. The fittings and connections at the wellhead are free from signs of leakage or other problems. Fittings at the tank battery are free from signs of leakage or problems. The load-outs are bull-plugged. Secondary containment is intact. ID Signage is present. The lease road is in good condition.
1651352429 2009-02-03 Drill / Deepen / Reopen No Violations drilling 2464 no violation
1705689755 2018-04-17 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiency: No current and accurate ID. At the time of this inspection, I observed the following: The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies
1762525769 2009-09-15 Preliminary Restoration No Violations The pits have been closed.
1835102481 2011-09-19 Salt Water Injection Well No Violations There is no surface water in the area. There is a water well on the property.
314750578 2018-2-13 0:00: UP No Violations 0.50
909832296 2009-1-29 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0415062245 US-OH-124413 2017-12-28 ID (a-i)
0909832296 US-OH-130393 2009-02-03 Drilling operation causing pollution and contamination

For data sources see[9]