X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21276

Well Details

Well ID: 34-085-21276
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: LITLE MOUNTAIN HOLDINGS LLC
License Status: Producing
License Date: 2020-10-13
Spud Date: 2008-06-18
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-06-25
Well Total Depth: 3631.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -81.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-05-06 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:5/6/2008, Expired Date:5/6/2009 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-06-25
Completion Report Received 2008-11-10
Construction Permit Expires 2009-05-06
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-12-17 3442 3468 53
3442 3468 53
3442 3468 53

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 63122 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 1264.00 100.00 149
2009 BASS ENERGY CO INC 13324.00 390.00 365
2010 BASS ENERGY CO INC 11754.00 295.00 365
2011 BASS ENERGY CO INC 9206.00 95.00 0
2012 BASS ENERGY CO INC 8286.00 173.00 366
2013 BASS ENERGY CO INC 7314.00 124.00 365
2014 BASS ENERGY CO INC 6517.00 71.00 365
2015 BASS ENERGY CO INC 6075.00 75.00 365
2016 BASS ENERGY CO INC 5044.00 53.00 365
2017 BASS ENERGY CO INC 4953.00 81.00 365
2018 BASS ENERGY CO INC 5355.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 497 149
2009 BASS ENERGY CO INC Brine 865 365
2010 BASS ENERGY CO INC Brine 600 365
2011 BASS ENERGY CO INC Brine 585
2012 BASS ENERGY CO INC Brine 575 366
2013 BASS ENERGY CO INC Brine 345 365
2014 BASS ENERGY CO INC Brine 415 365
2015 BASS ENERGY CO INC Brine 414 365
2016 BASS ENERGY CO INC Brine 252 365
2017 BASS ENERGY CO INC Brine 249 365
2018 BASS ENERGY CO INC Brine 340 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1042272658 2009-8-31 0:00: PW No Violations
-1225431136 2008-6-17 0:00: DD No Violations
-1403188541 2011-7-28 0:00: UP No Violations
-1534200195 2019-6-18 0:00: UP No Violations
-2031253212 2008-7-23 0:00: DD No Violations
-2139603433 2012-4-26 0:00: UP No Violations
-40157269 2013-10-23 0:00 UP No Violations
-89047217 2008-6-30 0:00: DD No Violations
0040157269 2013-10-23 UrbanProduction Wells No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 1 140-barrel steel production tank and 1 50-barrel brine tank, and separator unit. The wellhead and battery are both in separate board-on-board enclosures. The load-outs are bull-plugged. The ID and secondary containment are good. Spark arrestor, carbon filter, and low-pressure relief valve are present. No problems noted.
0089047217 2008-06-30 Drill / Deepen / Reopen No Violations Pits closed no violation.
0199172364 2017-12-11 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: Fittings and connections at the wellhead plunger-lift system and associated tank battery were secure, the access road was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. I walked and inspected the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features.
0746999956 2008-07-09 Drill / Deepen / Reopen No Violations area leveled
1042272658 2009-08-31 Production Wells No Violations No violations were found.
1218649738 2008-06-24 Drill / Deepen / Reopen No Violations Pits fenced
1224142113 2008-10-14 Preliminary Restoration No Violations
1225431136 2008-06-17 Drill / Deepen / Reopen No Violations Conductor cementing
1403188541 2011-07-28 UrbanProduction Wells No Violations Lease road stable. Fencing, dike, spacing in compliance. Lightning arrestor and charcoal filter installed. Vent hatches installed and closed. Feed lines bullplugged. Wellhead is rabbit catcher in good repair. No violations at this time.
1783145986 2017-04-10 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: the access road to the battery, which is comprised of a gravel-paved road that enters from the shared-use residential driveway and travels 30 feet to the battery, was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features.
1920391868 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located in a open, grassy portion on a residential property in an area of mostly sparse residential development. The well is comprised of a mechanical plunger-lift system in a board-on-board enclosure which is locked. Fittings and connections at the wellhead are secure. The battery is comprised of one 100-barrel steel production tank and one 50-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings and connections are secure. The secondary containment is intact and dry. Load-outs are secure. The areas surrounding the well and battery consist mainly of turf grass which is well maintained and free from impact or erosional deficits.
199172364 2017-12-11 0:00 UP No Violations 0.50
2031253212 2008-07-23 Drill / Deepen / Reopen No Violations working on restoration
2139603433 2012-04-26 UrbanProduction Wells No Violations My inspection today found a plunger lift system well in good repair. Identification sign for the well site is posted at tank battery. HB-278 equipment is installed on the tank battery. There are two low profile tanks and a mechincal separator in the battery. The dike around the battery is in good repair. The tank battery is fenced. The man doors to the well head fence and the tank battery fence were locked. Well site was landscaped correctly.
746999956 2008-7-9 0:00:0 DD No Violations

For data sources see[9]

References