X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21264

Well Details

Well ID: 34-085-21264
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: JIMMY
License Status: Producing
License Date: 2008-02-14
Spud Date: 2008-03-19
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-03-26
Well Total Depth: 3480.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -81.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-02-14 Proposed Formations:CLINTON, Issued Date:2/14/2008, Expired Date:2/13/2009 6:00:00 AM, Drilling unit acres:20.99, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-03-26
Completion Report Received 2008-05-05
Construction Permit Expires 2009-02-13
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-28 3281 3307 20
3281 3307 20
3281 3307 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 489 Mscf 100000 FRAC ALSO INVOLVED 19,550 GAL OF WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC 564.00 338.00 214
2009 GREAT PLAINS EXPLORATION LLC 3707.00 562.00 365
2010 GREAT PLAINS EXPLORATION LLC 3810.00 302.00 365
2011 GREAT PLAINS EXPLORATION LLC 9815.00 186.00 365
2012 GREAT PLAINS EXPLORATION LLC 8399.00 193.00 366
2013 GREAT PLAINS EXPLORATION LLC 3485.00 174.00 365
2014 GREAT PLAINS EXPLORATION LLC 2606.00 162.00 365
2015 GREAT PLAINS EXPLORATION LLC 1562.00 94.00 365
2016 ROCKEFELLER OIL COMPANY LLC 362.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC Brine 600 214
2009 GREAT PLAINS EXPLORATION LLC Brine 1300 365
2010 GREAT PLAINS EXPLORATION LLC Brine 520 365
2011 GREAT PLAINS EXPLORATION LLC Brine 360 365
2012 GREAT PLAINS EXPLORATION LLC Brine 520 366
2013 GREAT PLAINS EXPLORATION LLC Brine 375 365
2014 GREAT PLAINS EXPLORATION LLC Brine 295 365
2015 GREAT PLAINS EXPLORATION LLC Brine 121 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1757873684 2019-6-18 0:00: UP No Violations
-194451631 2017-9-25 0:00: UP No Violations 0.50
-362087845 2017-4-10 0:00: UP No Violations 0.50
-4776169 2017-12-11 0:00 UP No Violations 0.50
-482487536 2013-10-23 0:00 UP No Violations
0004776169 2017-12-11 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure and the surface casing was not gauged as required by special permit condition. At the time of this inspection, I observed the following: the load line valves were not locked and the surface casing was exposed but not gauged. The tanks must have a spark arrestor, low-pressure relief valve and carbon filter. In addition, there was signage at the well, but reflected the previous owner. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0194451631 2017-09-25 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and missing process safety equipment (spark arrestor, low-pressure relief valve, and carbon filter). At the time of this inspection, the noted deficiencies remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
0362087845 2017-04-10 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previous inspection and Compliance Notice issued for the following deficiencies: no locks on load-line valves, no spark arrestor, no low-pressure relief valves on tanks, no carbon filters, and no gauge on the surface casing annulus as required by special permit condition. At the time of this inspection, the noted deficiencies remained unaddressed. Repeated contacts to company represented John Magnussen have resulted in the following response: The deficiencies will be adressed as they are able.
0482487536 2013-10-23 UrbanProduction Wells No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 2 100-barrel steel production tanks, and 2 separator units. The battery is shared with the #1262 unit. There are no enclosures. The load-outs are bull-plugged. The wellhead is not identified. The tank battery ID only identifies the #1262 unit. No other problems noted. I will contact Great Plains about the ID placard.
0512929610 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located within the confines of the Little Mountain Country Club golf facility. The well is comprised of a mechanical plunger-lift system located at the top of the entry drive. Fittings and connections at the wellhead are secure. The battery is comprised of one 100-barrel steel production tank and one 100-barrel brine tank and separator unit in a diked area but not otherwise enclosed. Fittings and connections are secure. The secondary containment is intact and dry. Load-outs are secure. The areas surrounding the well and battery consist mainly of paved portions of the maintenance shop and associated driveway, parking, and equipment storage yard. I did not observe any signs of impact or drainage problems.
0614726776 2008-03-26 Drill / Deepen / Reopen No Violations 4.5 cement job
1323199559 2016-02-26 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system located on the grounds of the golf course. A tank battery comprised of two 100-barrel steel tanks, and mechanical separators is located remotely at the maintenance garage. Fittings and connections were bull-plugged but not locked. Low-pressure relief valve, spark arrestor, and carbon filter were not present. Fittings and c connections at the wellhead were secure and free from signs of leakage or problems. The 8.625-inch surface casing is exposed but not gauged as required under specific permit conditions. The owner must remedy the following by 04/04/2016: secure the load-line valves with locks. Properly gauge the 8.625-inch surface casing as required by permit condition. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1792449581 2008-03-19 Drill / Deepen / Reopen No Violations surface casing
2124966233 2009-09-10 Preliminary Restoration No Violations Preliminary restoration was completed and acceptable.
512929610 2015-4-22 0:00: UP No Violations 0.50
614726776 2008-3-26 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1323199559 US-OH-109243 2016-04-27 LOCKS
1323199559 US-OH-109244 2016-04-27 General Safety

For data sources see[9]