34-085-21262

Well Details

Well ID: 34-085-21262
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: ITALIAN
License Status: Producing
License Date: 2008-02-14
Spud Date: 2008-03-10
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-03-17
Well Total Depth: 3510.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-02-14 Proposed Formations:CLINTON, Issued Date:2/14/2008, Expired Date:2/13/2009 6:00:00 AM, Drilling unit acres:20.95, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-03-17
Completion Report Received 2008-05-05
Construction Permit Expires 2009-02-13
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-28 3308 3348 24
3308 3348 24
3308 3348 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 489 Mscf 100000 FRAC ALSO INVOLVED 19,295 GAL WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC 10325.00 171.00 214
2009 GREAT PLAINS EXPLORATION LLC 12231.00 562.00 365
2010 GREAT PLAINS EXPLORATION LLC 8705.00 302.00 365
2011 GREAT PLAINS EXPLORATION LLC 5122.00 186.00 365
2012 GREAT PLAINS EXPLORATION LLC 7961.00 193.00 366
2013 GREAT PLAINS EXPLORATION LLC 6331.00 174.00 365
2014 GREAT PLAINS EXPLORATION LLC 6165.00 162.00 365
2015 GREAT PLAINS EXPLORATION LLC 2248.00 94.00 365
2016 ROCKEFELLER OIL COMPANY LLC 1074.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 GREAT PLAINS EXPLORATION LLC Brine 280 214
2009 GREAT PLAINS EXPLORATION LLC Brine 0 365
2010 GREAT PLAINS EXPLORATION LLC Brine 520 365
2011 GREAT PLAINS EXPLORATION LLC Brine 360 365
2012 GREAT PLAINS EXPLORATION LLC Brine 520 366
2013 GREAT PLAINS EXPLORATION LLC Brine 375 365
2014 GREAT PLAINS EXPLORATION LLC Brine 295 365
2015 GREAT PLAINS EXPLORATION LLC Brine 121 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-243369519 2013-10-23 0:00 UP No Violations
-362194163 2015-4-22 0:00: UP No Violations 1.00
-844517586 2017-12-11 0:00 UP No Violations 0.50
0243369519 2013-10-23 UrbanProduction Wells No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 2 100-barrel steel production tanks, and 2 separator units. The battery is shared with the #1264 unit. There are no enclosures. The load-outs are bull-plugged. The wellhead is not identified. The tank battery ID is good. No other problems noted. I will contact Great Plains about the ID placard for the wellhead.
0280245173 2008-03-18 Drill / Deepen / Reopen No Violations rig moving
0362194163 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located within the confines of the Little Mountain Country Club golf facility. The well is comprised of a mechanical plunger-lift system located at the fringe of the golf course fairway. Fittings and connections at the wellhead are secure. The battery is comprised of one 100-barrel steel production tank and one 100-barrel brine tank and separator unit in a diked area but not otherwise enclosed. Fittings and connections are secure. The secondary containment is intact and dry. Load-outs are secure. The areas surrounding the well and battery consist mainly of paved portions of the maintenance shop and associated driveway, parking, and equipment storage yard. I did not observe any signs of impact or drainage problems.
0844517586 2017-12-11 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure and the surface casing was not gauged as required by special permit condition. At the time of this inspection, I observed the following: the load line valves were not locked and the surface casing was exposed but not gauged. The tanks must have a spark arrestor, low-pressure relief valve and carbon filter. In addition, the wellhead requires updated signage. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0897806142 2017-09-25 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and missing process safety equipment (spark arrestor, low-pressure relief valve, and carbon filter), and no gauge at the surface casing as required under special permit conditions. At the time of this inspection, the noted deficiencies remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
1087644071 2008-03-19 Drill / Deepen / Reopen No Violations pits open addvise to close ASP
1270880102 2008-03-28 Completion Testing No Violations checked silt fence
1423537153 2017-04-10 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previous inspection and Compliance Notice issued for the following deficiencies: no locks on load-line valves, no spark arrestor, no low-pressure relief valves on tanks, no carbon filters, and no gauge on the surface casing annulus as required by special permit condition. At the time of this inspection, the noted deficiencies remained unaddressed. Repeated contacts to company represented John Magnussen have resulted in the following response: The deficiencies will be adressed as they are able.
1456512708 2016-02-26 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system located on the grounds of the golf course. A tank battery comprised of two 100-barrel steel tanks, and mechanical separators is located remotely at the maintenance garage. Fittings and connections were bull-plugged but not locked. Low-pressure relief valve, spark arrestor, and carbon filter were not present. Fittings and c connections at the wellhead were secure and free from signs of leakage or problems. The 8.625-inch surface casing is exposed but not gauged as required under specific permit conditions. The owner must remedy the following by 04/04/2016: secure the load-line valves with locks. Properly gauge the 8.625-inch surface casing as required by permit condition. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1538299489 2019-6-18 0:00: UP No Violations
2092332660 2008-03-10 Drill / Deepen / Reopen No Violations cementing conductor in
280245173 2008-3-18 0:00: DD No Violations
897806142 2017-9-25 0:00: UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1456512708 US-OH-113225 2016-04-27 LOCKS
1456512708 US-OH-113226 2016-04-27 TANKS (a-i)
1456512708 US-OH-113227 2016-04-27 General Safety

For data sources see[9]