34-085-21248

Well Details

Well ID: 34-085-21248
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: HOLLY
License Status: Producing
License Date: 2007-10-02
Spud Date: 2007-10-23
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2007-10-28
Well Total Depth: 3570.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-10-02 Proposed Formations:CLINTON, Issued Date:10/2/2007, Expired Date:10/1/2008 6:00:00 AM, Drilling unit acres:20.4048, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-10-28
Reached Total Depth 2007-10-28
Completion Report Received 2007-12-10
Change of Owner 2008-04-02 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 7447, GREAT PLAINS EXPLORATION LLC
Construction Permit Expires 2008-10-01
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-02-21 3371 3388 14
3371 3388 14
3371 3388 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 500 Bbl 100000 FRAC ALSO USED 603 MSCF OF N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 GREAT PLAINS EXPLORATION LLC 870.00 0.00 30
2008 GREAT PLAINS EXPLORATION LLC 11022.00 76.00 365
2009 GREAT PLAINS EXPLORATION LLC 6485.00 45.00 365
2010 GREAT PLAINS EXPLORATION LLC 1338.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 970.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 1218.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 285.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 40.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 340.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 GREAT PLAINS EXPLORATION LLC Brine 0 30
2008 GREAT PLAINS EXPLORATION LLC Brine 1330 365
2009 GREAT PLAINS EXPLORATION LLC Brine 740 365
2010 GREAT PLAINS EXPLORATION LLC Brine 160 365
2011 GREAT PLAINS EXPLORATION LLC Brine 160 365
2012 GREAT PLAINS EXPLORATION LLC Brine 0 366
2013 GREAT PLAINS EXPLORATION LLC Brine 0 365
2014 GREAT PLAINS EXPLORATION LLC Brine 0 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1760372604 2013-7-25 0:00: UP No Violations
-92512745 2017-4-10 0:00: UP No Violations 0.50
0092512745 2017-04-10 UrbanProduction Wells No Violations I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required and the wellhead enclosure was missing. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a gravel-paved road that enters from Ravenna Road and is shared with the residential parcel and travels 50 feet to the well and battery, was in good condition with no drainage problems or wash-outs. The battery enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load-line valves remained unsecure and require locks, the ID signage had not been updated to reflect the recent change in ownership, and the wellhead enclosure remains dismantled. The owner has indicated that the deficiencies will be fixed but will not provide a timetable.
0472646498 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead is located behind the referenced house on Ravenna Road. The wellhead and battery are located in a gravel drive and parking area behind the house. The well is comprised of a mechanical plunger-lift system which had been enclosed but the sides of the board-on-board enclosure have fallen down. Fittings and connections at the wellhead are secure. The battery is comprised of one 210-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings are secure. Load-outs are locked. The containment dike is intact and dry. I walked the areas outside of the wellhead and battery including areas down gradient topographically and did not observe any signs of impact or drainage problems associated with the unit. The access road is unpaved by well drained and passable.
0616506961 2017-12-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and wellhead enclosure that had been torn down and not fixed or replaced. At the time of this inspection, I observed the following: there were no locks at the load-line valves and the wellhead enclosure remained broken down. In addition, the steel brine tank was displaying advanced and substantial corrosion on the sidewall requiring intervention before failure of the tank integrity. The ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
0964302529 2016-02-09 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and associated battery are located behind the single-family house at this location. The well and battery are accessed via a short, unpaved driveway shared with the house At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in the open back yard area. Fittings and connections at the wellhead were secure. The 8.625-inch casing is open and plumbed into the 4.5-inch production casing. The former board-on-board enclosure has been removed. The battery is comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank and separator in a separate board-on-board enclosure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked and the wellhead enclosure must be replaced. The owner must remedy the following by 04/03/2016: secure the load-line valves with locks. Repair and secure the wellhead enclosure. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1160362308 2009-09-10 Preliminary Restoration No Violations Preliminary restoration was completed and passed inspection.
1559655936 2019-6-4 0:00:0 UP No Violations
1760372604 2013-07-25 UrbanProduction Wells No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 210-barrel production tank, one steel 140-barrel brine tank, mechanical separator in separate board-on-board enclosures. The unit ID is present, and tank spacing and meets requirements. The loadouts are locked. The battery secondary containment is good. No evidence of leaks or problems.
2108473495 2020-7-28 0:00: UP No Violations
472646498 2015-4-22 0:00: UP No Violations 0.50
616506961 2017-12-5 0:00: UP No Violations 0.50
964302529 2016-2-9 0:00:0 UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0964302529 US-OH-131046 2016-04-27 FENCING (a-d)
0964302529 US-OH-131047 2016-04-27 LOCKS

For data sources see[9]