34-085-21227

Well Details

Well ID: 34-085-21227
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: ACTIVITIES PRESS
License Status: Producing
License Date: 2007-01-25
Spud Date: 2007-05-29
Spud Drilling Contractor: ROSS WELL SERVICE
Final Drill Date: 2007-06-05
Well Total Depth: 3600.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.230000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-01-25 Proposed Formations:CLINTON, Issued Date:1/25/2007, Expired Date:1/25/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-06-05
Reached Total Depth 2007-06-05
Completion Report Received 2007-08-09
Construction Permit Expires 2008-01-25
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-11-07 3363 3396 26
3363 3396 26
3363 3396 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 19450 Gal 100000 525M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 JOHN D OIL & GAS COMPANY 9570.00 0.00 182
2008 JOHN D OIL & GAS COMPANY 13386.00 91.00 365
2009 JOHN D OIL & GAS COMPANY 10438.00 15.00 365
2010 JOHN D OIL & GAS COMPANY 7541.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 9997.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 10964.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 9821.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 7944.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 3589.00 0.00 365
2016 DAVID OIL COMPANY LLC 8.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 JOHN D OIL & GAS COMPANY Brine 960 182
2008 JOHN D OIL & GAS COMPANY Brine 480 365
2009 JOHN D OIL & GAS COMPANY Brine 320 365
2010 JOHN D OIL & GAS COMPANY Brine 400 365
2011 JOHN D OIL & GAS COMPANY Brine 240 365
2012 JOHN D OIL & GAS COMPANY Brine 160 366
2013 JOHN D OIL & GAS COMPANY Brine 240 365
2014 JOHN D OIL & GAS COMPANY Brine 50 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1055072237 2020-7-28 0:00: UP No Violations
-1625598216 2011-7-28 0:00: UP No Violations
-171122176 2018-2-13 0:00: UP No Violations 0.50
-1851108028 2017-12-5 0:00: UP No Violations 0.50
-2092054385 2011-3-29 0:00: PL No Violations
-441513356 2016-2-9 0:00:0 UP No Violations 0.50
-837036967 2007-5-30 0:00: DD No Violations
0045345050 2017-04-10 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a shared-use asphalt-paved road was in good condition. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance deficiency; the load line valves were not secured with locks as required, the ID signage had not been updated to reflect the recent change in ownership. I contacted the well tender (John Magnussen) and advised him about the deficiency. He indicated that the items would be fixed ASAP.
0092471829 2007-05-30 Drill / Deepen / Reopen No Violations drilling
0171122176 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and ID not current and accurate. At the time of this inspection, the noted deficiency remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
0441513356 2016-02-09 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated battery are located in an otherwise open, grassy area on the east side of the commercial building at this location. The well is accessed via a short, unpaved road that connects to the existing asphalt-paved driveway. The battery is immediately adjacent to the asphalt drive. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of two 100-barrel steel production tanks and separator in separate board-on-board enclosures. Enclosure gates were locked and secure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked.
0558257345 2019-01-25 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1851108028, regarding updated identification at the well site location, locks on the load-line valves. At the time of this inspection, the load-lines were not locked as required and the identification has not been updated to reflect current ownership. The door on the fencing surrouding the well was also missing and needs to be replaced and locked.

David Oil Company, LLC needs to: 1) Update and install identification reflecting current owner information 2) Install locks on the load-line valve on the tanks 3) Reinstall the door on the fencing surrounding the well

0837036967 2007-05-30 Drill / Deepen / Reopen No Violations drilling 2800
0914648767 2009-10-26 Production Wells No Violations There were no violations at the time of inspection.
1357220154 2012-12-05 UrbanProduction Wells Violations Noted The unit is comprised of a two-tank battery (1 140-barrel production and 1 100-barrel brine) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate wood board-on-board enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The gates are locked.
1423841950 2015-02-13 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well is located in a commercial/light industrial area on the north side of Crile Rd. The well is comprised of a wellhead with mechanical plunger lift located 200 feet from the tank battery. The battery, mechanical separator, and battery are in separate board-on-board enclosures. The enclosure for the separator is unlocked and I found the gate to be left open. Load outs at the battery are bull-plugged. Connections and fittings are secure and free from signs of leakage or problems. At the time of this inspection, there are 10 to 15 inches of snowfall, which hinders a thorough inspection of surficial features (e.g. access road, secondary containment interior. I notified Tim Reilly (John D. Oil & Gas) about the need for a lock on the gate. I will follow-up in 30 days.
1523971565 2018-04-17 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and ID not current and accurate. At the time of this inspection, the noted deficiency remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. The well was shut-in and no in active production.
1532301953 2007-05-22 Drill / Deepen / Reopen No Violations
1625598216 2011-07-28 UrbanProduction Wells Violations Noted Dike, ID and fencing in compliance. Vent hatches installed and closed. Feedlines are bullplugged. Lightning arrestor and charcoal filter not installed. No locks on gates.
1761357899 2013-10-09 UrbanProduction Wells No Violations The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a mechanical plunger lift unit and is producing. The battery is comprised of 2 100-barrel low-boy steel tanks and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. The hatch lid has been left open by the well tender. The ID placard needs to be moved to the outside of the battery and made visible. Ill contact John D. Oil and let them know about the issues. No other problems otherwise noted.
1768450386 2013-12-03 UrbanProduction Wells No Violations The locks and process safety equipment have been added. No other problems noted.
1851108028 2017-12-05 UrbanProduction Wells Violations Noted I inspected the well location as part of routine inspection activity. The well and associated battery are located behind a commercial building, at the edge of the existing asphalt paved parking and drive area. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate board-on-board enclosures which were locked. Fittings and connections at the well and battery were secure and free from signs of leakage. The secondary containment was intact. I noted the following deficiencies: the load-lines were not locked as required. The ID signage had not been updated to reflect the change of ownership that occurred over 12 month prior to this inspection. The owner must place locks at the load-line valves and place compliant unit identification at the well within 30 days or be subject to additional enforcement. Contact Inspector Stephen Tompkins at 330-907-4647 with questions about this compliance notice.
2049003611 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
2092054385 2011-03-29 Preliminary Restoration No Violations Preliminary restoration was completed.
45345050 2017-4-10 0:00: UP No Violations
558257345 2019-1-25 0:00: UP No Violations 0.50
914648767 2009-10-26 0:00 PW No Violations
92471829 2007-5-30 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1357220154 US-OH-110139 2015-02-05 OPERATIONMAINTANCE (a-c)
1625598216 US-OH-115990 2011-08-01 LOCKS
1625598216 US-OH-115991 2011-08-01 General Safety
1851108028 US-OH-118512 2017-12-28 ID (a-i)
1851108028 US-OH-118513 2017-12-28 LOCKS

For data sources see[9]