Well Details

Well ID: 34-085-21224
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: LAKE COUNTY FARMERS
License Status: Producing
License Date: 2006-11-01
Spud Date: 2006-12-12
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2006-12-22
Well Total Depth: 3280.00 ft
Configuration: Vertical
Latitude: 41.680000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-11-01 Proposed Formations:CLINTON, Issued Date:11/1/2006, Expired Date:11/1/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-12-22
Reached Total Depth 2006-12-22
Completion Report Received 2007-01-31
Construction Permit Expires 2007-11-01
Change of Owner 2017-10-06 Operator changed from 169, JAMES R SMAIL INC to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-10-06

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-04-12 3087 3097 11
2007-04-12 3104 3107 4
3087 3097 11
3104 3107 4
3121 3122 2
3087 3097 11
2007-04-12 3121 3122 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 18720 Gal 80000 600 MSCF OF N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 JAMES R SMAIL INC 1924.00 53.00 270
2008 JAMES R SMAIL INC 1910.00 90.00 270
2009 JAMES R SMAIL INC 2774.00 0.00 270
2010 JAMES R SMAIL INC 3164.00 0.00 270
2011 JAMES R SMAIL INC 3614.00 0.00 365
2012 JAMES R SMAIL INC 2564.00 0.00 366
2013 JAMES R SMAIL INC 4088.00 0.00 365
2014 JAMES R SMAIL INC 3746.00 0.00 365
2015 JAMES R SMAIL INC 937.00 0.00 365
2016 JAMES R SMAIL INC 917.00 0.00 365
2017 JAMES R SMAIL INC 2637.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 JAMES R SMAIL INC Brine 1360 270
2008 JAMES R SMAIL INC Brine 0 270
2009 JAMES R SMAIL INC Brine 880 270
2010 JAMES R SMAIL INC Brine 0 270
2011 JAMES R SMAIL INC Brine 375 365
2012 JAMES R SMAIL INC Brine 400 366
2013 JAMES R SMAIL INC Brine 480 365
2014 JAMES R SMAIL INC Brine 0 365
2015 JAMES R SMAIL INC Brine 0 365
2016 JAMES R SMAIL INC Brine 0 365
2017 JAMES R SMAIL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1733177752 2006-12-20 0:00 DD No Violations
-1872388028 2006-12-13 0:00 DD No Violations
-190019081 2007-5-8 0:00:0 DD No Violations
-1935717682 2011-3-3 0:00:0 PW No Violations
-2040374535 2017-12-11 0:00 UP No Violations 0.50
-275665592 2019-2-14 0:00: UP No Violations 0.50
0190019081 2007-05-08 Drill / Deepen / Reopen No Violations checking site for restoration area graded
0205745280 2007-05-22 Production Wells No Violations in compliance
0275665592 2019-02-14 UrbanProduction Wells Violations Noted I conducted an inspection on this well. During this inspection, the well was observed to be equipped with a pumping unit and not in production. The valve on the tubing and 2 inch flow line was in the closed position. The well was enclosed with a fence and locked door. The tank battery was comprised of two 100 BBL tanks, one 50 BBL tank and a mechanical separator. Valves on the separator were open. Urban production equipment was installed on the production tanks. The diked tank battery was enclosed by a chain link fence and had a locked door. Legible identification was located at the well and tank battery, however it has not been updated to reflect the new owner information. Lease access to the well and tank battery was stable and secured with a locked gate. I contacted David Oil Company and discussed with office personnel that up-to-date identification needs to be installed at the well and tank battery location.
0445710855 2009-10-20 Production Wells No Violations No violations were found at the time of inspection.
0885921530 2009-09-10 Production Wells No Violations No violations were found.
1291154166 2007-09-25 Preliminary Restoration No Violations area graded and seeded
1374775953 2013-07-25 UrbanProduction Wells No Violations The producing unit consists of a wellhead and pumpjack unit and an aboveground storage tank (AST) battery with two steel 140-barrel production tanks, one poly 50-barrel brine tank, mechanical separator in separate chain-link enclosures. The unit ID is present, and tank spacing and meets requirements. The loadouts are locked. The battery secondary containment is good. No evidence of leaks or problems. There is a locked gate at the lease road which has an ID placard. The leased road is well maintained and the site is in good condition.
1412267931 2014-10-02 Production Wells No Violations I inspected the location of this producing unit as part of routine inspection activity. The well is currently producing. Production reports are current. The well and surrounding area are free from signs of leakage or problems. The tank battery secondary containment is intact. Load-outs are bull-plugged and the gates are locked. No problems noted.
1501784585 2017-08-03 UrbanProduction Wells No Violations I inspected this production well as part of routine inspection activity. The well and associated battery are located on an otherwise undeveloped parcel, in a clearing surrounded by dense woodlands. The access road was in good condition. Fittings and connections at the well and battery were secure. The secondary containment was intact and free from signs of spills or leaks. The load lines were secure. I walked the areas surrounding the well and battery and found no signs of impact or degradation to the natural greenscape.
1572886578 2019-11-4 0:00: UP No Violations
1580222304 2020-1-28 0:00: UP No Violations 0.40
1733177752 2006-12-20 Drill / Deepen / Reopen No Violations drilling 2700 checking site due to phone calls regrading noise and odors on site with gas meter no readings regrading noise rig has hospital grade mufflers.
1872388028 2006-12-13 Drill / Deepen / Reopen No Violations meeting on site location made checking pit location
1935717682 2011-03-03 Production Wells No Violations There were no violations at the time.
2040374535 2017-12-11 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead with pump jack system and associated battery are located on the east side of Auburn road in a clearing on an otherwise undeveloped parcel. At the time of this inspection, I observed the following: Fittings and connections at the wellhead and associated tank battery were secure in separate chain-link enclosures, the access road was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. I walked and inspected the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I noted that the well which had recently changed ownership, remained with unit ID from the previous owner. The new owner must update the signage as soon as possible. I notified the owner about the deficiency.
205745280 2007-5-22 0:00: PW No Violations
445710855 2009-10-20 0:00 PW No Violations
885921530 2009-9-10 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0275665592 US-OH-122847 2019-02-27 9-05E1 ID (a-i)

For data sources see[9]