34-085-21210

Well Details

Well ID: 34-085-21210
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: GAMBER
License Status: Producing
License Date: 2006-07-07
Spud Date: 2006-11-23
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-11-22
Well Total Depth: 3142.00 ft
Configuration: Vertical
Latitude: 41.700000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-07-07 Proposed Formations:CLINTON, Issued Date:7/7/2006, Expired Date:7/7/2007 6:00:00 AM, Drilling unit acres:31.46, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-11-22 RBDMS Rec
Reached Total Depth 2006-11-22 RBDMS Rec
Completion Report Received 2007-01-16 RBDMS Rec
Construction Permit Expires 2007-07-07 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-27 2946 3004 23
2946 3004 23
2946 3004 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 18900 Gal 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 855.00 0.00 12
2007 JOHN D OIL & GAS COMPANY 35095.00 0.00 365
2008 JOHN D OIL & GAS COMPANY 32227.00 26.00 365
2009 JOHN D OIL & GAS COMPANY 30790.00 0.00 365
2010 JOHN D OIL & GAS COMPANY 18005.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 14912.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 15373.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 12155.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 14833.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 10914.00 0.00 365
2016 DAVID OIL COMPANY LLC 1719.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 230 12
2007 JOHN D OIL & GAS COMPANY Brine 240 365
2008 JOHN D OIL & GAS COMPANY Brine 480 365
2009 JOHN D OIL & GAS COMPANY Brine 240 365
2010 JOHN D OIL & GAS COMPANY Brine 160 365
2011 JOHN D OIL & GAS COMPANY Brine 320 365
2012 JOHN D OIL & GAS COMPANY Brine 160 366
2013 JOHN D OIL & GAS COMPANY Brine 0 365
2014 JOHN D OIL & GAS COMPANY Brine 0 365
2015 JOHN D OIL & GAS COMPANY Brine 100 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1430256532 2006-11-22 0:00 DD No Violations
-1682687172 2019-9-3 0:00:0 UP No Violations
-677808782 2013-9-10 0:00: UL No Violations
0236062035 2015-01-13 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to a previously-issued compliance notice regarding missing portions of the secondary containment at the tank battery. The missing portions have not been addressed as of this inspection. Tim Reilly of John D. Oil and Gas has indicated that they will address the issue at some point as they are able.
0677808782 2013-09-10 UrbanPreliminary Restoration Violations Noted The producing unit consists of a wellhead with mechanical plunger lift system and aboveground storage tank battery. The battery, separator, and wellhead are in separate board-on-board enclosures. The battery is comprised of 1 140-barrel low-boy steel production tank, 1 140-barrel low-boy steel brine tank, and separator unit. The secondary containment dike in the battery is completely missing in sections. The corrections should be made within 90 days.
0752922746 2006-11-25 Drill / Deepen / Reopen No Violations surface cemeting
1430256532 2006-11-22 Drill / Deepen / Reopen No Violations making location
1455633625 2016-02-16 UrbanProduction Wells Violations Noted I inspected this well location as par6t of routine inspection activity. At the time of this inspection I observed the following elements: A wellhead with mechanical plunger lift system, a mechanical separator, and a tank battery system in separate board-on-board enclosures. Access to the wellhead is via the shared, asphalt-paved driveway. Fittings and connections at the well and battery were secure and free from evidence of problems or leakage. The wellhead enclosure gate was unlocked due to a broken hasp. The load-line valves are not secured with locks as required. The tanks are not fitted with spark arrestors, vent stack low-pressure relief valves, or carbon-filter. The owner must remedy the following by 03/25/2016: secure the wellhead gate with a lock, secure the load-line valves with locks, fit spark arrestors, low-pressure relief valves and carbon filter at the tank battery. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1492612254 2017-04-19 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves and missing process safety equipment (spark-arrestor, low-prsssure relief valve, carbon filter). At the time of this inspection, I observed the following: The load-line valves were not secured with locks. The tank battery was In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages.
1504706236 2017-09-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing process safety equipment (low-pressure relief valve, spark arrestor, carbon filter) , the load-lines were not secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1524833782 2018-04-27 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing process safety equipment (low-pressure relief valve, spark arrestor, carbon filter) , the load-lines were not secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1773169891 2006-11-29 Drill / Deepen / Reopen No Violations drilling 2600
224889989 2020-4-22 0:00: UP No Violations
236062035 2015-1-13 0:00: UP No Violations
752922746 2006-11-25 0:00 DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0677808782 US-OH-127666 2013-09-12 TANKS (a-I)
1455633625 US-OH-113183 2016-04-27 LOCKS
1455633625 US-OH-113184 2016-04-27 TANKS (a-i)

For data sources see[9]