Well History

Well Status Well Status Date Comment
APP 2006-05-09 Proposed Formations:CLINTON, Issued Date:5/9/2006, Expired Date:5/9/2007 6:00:00 AM, Drilling unit acres:21.0148, Proposed Well Type:OG, Proposed Well Class:EOUT
Completed 2006-09-23 RBDMS Rec
Reached Total Depth 2006-09-23 RBDMS Rec
Completion Report Received 2007-01-16 RBDMS Rec
Construction Permit Expires 2007-05-09 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-28 3432 3488 26
3432 3488 26
3432 3488 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 24101 Gal 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 4088.00 0.00 84
2007 JOHN D OIL & GAS COMPANY 2503.00 25.00 192
2008 JOHN D OIL & GAS COMPANY 3759.00 63.00 365
2009 JOHN D OIL & GAS COMPANY 2778.00 43.00 365
2010 JOHN D OIL & GAS COMPANY 2806.00 43.00 365
2011 JOHN D OIL & GAS COMPANY 2541.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 1935.00 17.00 366
2013 JOHN D OIL & GAS COMPANY 1368.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 1219.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 479.00 0.00 365
2016 DAVID OIL COMPANY LLC 1.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 0 84
2007 JOHN D OIL & GAS COMPANY Brine 900 192
2008 JOHN D OIL & GAS COMPANY Brine 720 365
2009 JOHN D OIL & GAS COMPANY Brine 400 365
2010 JOHN D OIL & GAS COMPANY Brine 320 365
2011 JOHN D OIL & GAS COMPANY Brine 320 365
2012 JOHN D OIL & GAS COMPANY Brine 320 366
2013 JOHN D OIL & GAS COMPANY Brine 80 365
2014 JOHN D OIL & GAS COMPANY Brine 230 365
2015 JOHN D OIL & GAS COMPANY Brine 160 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1313550475 2007-5-16 0:00: PW No Violations
-343901530 2009-9-10 0:00: PL No Violations
-607898399 2007-5-8 0:00:0 DD No Violations
-883329592 2017-5-5 0:00:0 UP No Violations 0.50
0343901530 2009-09-10 Preliminary Restoration No Violations Preliminary restoration was completed.
0607898399 2007-05-08 Drill / Deepen / Reopen No Violations Pits closed
0779086339 2017-09-20 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: The load lines were noted to be unlocked and unsecure At the time of this inspection, the indicated deficiencies remained. In addition, the ID signage remained unchanged and had not been updated to reflect the change in ownership that had occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
0883329592 2017-05-05 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves, perforated production and brine tanks, and broken and unlocked fence enclosures. At the time of this inspection, I observed the following: The wellhead was comprised of a pump jack system with associated tank battery. The load-line valves were not secured with locks. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages.
1132031586 2007-09-25 Drill / Deepen / Reopen No Violations area graded and seeded
1312216069 2011-07-28 UrbanProduction Wells Violations Noted Dike, fencing, spacing in compliance. Vent hatches are installed and closed. ID sign posted. Lightning arrestor and charcoal filter installed. No violations at this time.
1313550475 2007-05-16 Production Wells No Violations
1371969793 2012-11-07 Production Wells No Violations The unit is comprised of a 2-tank battery (1 100-barrel production tank and 1 100-barrel brine tank). The wellhead includes a mechanical plunger lift located in a 6-foot chian-link enclosure. The mechanical separator is located whithin a third, separate enclosure. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. No violations noted.
1421336672 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead is located behind the referenced house on Girdled Rd. The wellhead and battery are located on a level grassy area behind, and slightly above the house. The well is comprised of a pump jack system in a chain-link enclosure Fittings and connections at the wellhead are secure. The battery is comprised of one 100-barrel low boy steel production tank and one 100-barrel low boy brine tank and separator unit in separate chain-link enclosures. Fittings are secure. Load-outs are locked. The containment dike is intact and dry. I walked the areas outside of the wellhead and battery including areas down gradient topographically and did not observe any signs of impact or drainage problems associated with the unit. The access road is unpaved by well drained and passable.
1687000628 2006-09-18 Drill / Deepen / Reopen No Violations cementing surface
1844402502 2013-10-09 UrbanProduction Wells No Violations The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate chain-link enclosures. The wellhead is a pump jack unit and is producing. The battery is comprised of 2 100-barrel steel lowboy tanks and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked . No problems noted.
1982293486 2016-02-09 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and associated battery are located behind the single-family house at this location. The well and battery are accessed via a short, unpaved road that enters from Girdled Road. At the time of this inspection, I observed the following: a wellhead with gas-fired pump jack system in a chain-link enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of two 100-barrel steel production tanks, and separator in a separate chain-link enclosure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked and enclosure gate at the battery was unlocked. The owner must remedy the following by 04/08/2016: secure the load-line valves and entry gate with locks. Place ID signage at the entry gate. Fit the new production tank with spark arrestor, low-pressure relief valve, and carbon filter as required. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
312897625 2019-6-18 0:00: UP No Violations
779086339 2017-9-20 0:00: UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1312216069 US-OH-108847 2011-08-01 General Safety
1982293486 US-OH-120053 2016-04-27 ID (a-i)
1982293486 US-OH-120054 2016-04-27 LOCKS

For data sources see[9]

References