34-085-21197

Well Details

Well ID: 34-085-21197
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Leroy Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: MAGGIE
License Status: Producing
License Date: 2006-05-04
Spud Date: 2006-12-13
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-12-18
Well Total Depth: 3331.00 ft
Configuration: Vertical
Latitude: 41.700000
Longitude: -81.180000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-05-04 Proposed Formations:CLINTON, Issued Date:5/4/2006, Expired Date:5/4/2007 6:00:00 AM, Drilling unit acres:20.671, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-12-18 RBDMS Rec
Reached Total Depth 2006-12-18 RBDMS Rec
Completion Report Received 2007-03-16 RBDMS Rec
Construction Permit Expires 2007-05-04 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-07-02 3127 3172 22
3127 3172 22
3127 3172 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 14600 Gal 100000 FRAC INCLUDED 562 MSCF OF N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 GREAT PLAINS EXPLORATION LLC 10280.00 68.00 365
2008 GREAT PLAINS EXPLORATION LLC 5857.00 23.00 365
2009 GREAT PLAINS EXPLORATION LLC 5423.00 48.00 365
2010 GREAT PLAINS EXPLORATION LLC 4220.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 3929.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 3943.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 4604.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 4853.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 810.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 GREAT PLAINS EXPLORATION LLC Brine 720 365
2008 GREAT PLAINS EXPLORATION LLC Brine 1190 365
2009 GREAT PLAINS EXPLORATION LLC Brine 780 365
2010 GREAT PLAINS EXPLORATION LLC Brine 560 365
2011 GREAT PLAINS EXPLORATION LLC Brine 480 365
2012 GREAT PLAINS EXPLORATION LLC Brine 560 366
2013 GREAT PLAINS EXPLORATION LLC Brine 480 365
2014 GREAT PLAINS EXPLORATION LLC Brine 310 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1279576084 2017-9-22 0:00: PW No Violations
-259648777 2013-5-31 0:00: UP No Violations
-605097614 2019-3-26 0:00: PW No Violations
0259648777 2013-05-31 UrbanProduction Wells No Violations The producing unit consists of the following elements: a wellhead with mechanical plunger lift, and a tank battery system. There are no enclosures. The tank battery is comprised of one 210-barrel and and mechanical separator. Secondary containment is present at the tank battery. Unit spacing is in accordance with the regulations. There is a unit ID at the tank battery. I did not observe any signs of leakage or other problems.
0424775435 2008-06-10 Preliminary Restoration No Violations
0605097614 2019-03-26 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice # 1531499835, regarding the installation of updated identification at the well site and the removal of the 210 BBL tank due to numerous holes along the side. At the time of this inspection, the identification has been installed on the mechanical separator with the current owner information. The 210 BBL tank still has not been removed and still needs removed from the diked tank battery due to numerous holes near the top of the tank. The well was not in production, at the time of this inspection.
0718802039 2010-09-02 Production Wells No Violations There were no violations found at the time.
1279576084 2017-09-22 Production Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system, with associated tank battery. The system is located in a clearing within a wooded area on a larger, undeveloped parcel. Fittings and connections were secure. I did note that the ID signage had not been changed or updated to reflect the change of ownership that had occurred in 2016. The owner has made repeated pledges to update the signage on the well but with no results.
1417795955 2014-12-05 Production Wells No Violations I inspected this producing location as part of routine inspection activity. The wellhead and battery are located at the terminus of a dedicated lease road which enters from Vrooman Rd. The wellhead plunger lift is in operation and the fittings and connections are free from signs of leakage or other problems. The battery is comprised of 1 210-barrel steel production tank. The tank is exhibiting significant corrosion near the top with several penetrating holes. The integrity of this tank has been compromised and must be removed from the battery. Ive notified Great Plains about the issue and am waiting for a response.
1531499835 2018-07-13 Production Wells Violations Noted I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system, with associated tank battery. The system is located in a clearing within a wooded area on a larger, undeveloped parcel. Fittings and connections were secure. I did note that the ID signage had not been changed or updated to reflect the change of ownership that had occurred in 2016. In addition, the 210-barrel production tank was severely corroded with numerous perforating holes that have rendered the tank not fit for storage. The owner must correct the missing signage and remove the failed 210-barrel production tank from service within 30 days, and prior to returning the well to production. Please contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this compliance notice.
1748655849 2016-02-24 Production Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system and tank battery with one 210-barrel steel tank and separator unit. Tnak lids were closed and secure. Load-lines were plugged and secure. Secondary contaiment was intact. I walked the areas around the wellhead and battery and did not observe any signs of impact relating to the on-going production activity. Access to the well and battery was afforded by a shared-use unpaved access road which was in good condition.
1945525222 2020-4-20 0:00: PW No Violations
424775435 2008-6-10 0:00: PL No Violations
718802039 2010-9-2 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1531499835 US-OH-114703 2018-08-21 Failure to legibly identify well
1531499835 US-OH-114704 2018-08-21 Equipment pressure rated below operating pressure

For data sources see[9]