34-085-21187

Well Details

Well ID: 34-085-21187
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: RUPLE
License Status: Producing
License Date: 2006-01-25
Spud Date: 2006-01-29
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-02-04
Well Total Depth: 3152.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -81.370000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-01-25 Proposed Formations:CLINTON, Issued Date:1/25/2006, Expired Date:1/25/2007 6:00:00 AM, Drilling unit acres:21.85, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-01-29 RBDMS Rec
Completed 2006-02-04 RBDMS Rec
Reached Total Depth 2006-02-04 RBDMS Rec
Completion Report Received 2006-05-08 RBDMS Rec
Construction Permit Expires 2007-01-25 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-07-27 2997 3035 16
2997 3035 16
2997 3035 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 20318 Gal 100000 623M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 9286.00 53.00 256
2007 JOHN D OIL & GAS COMPANY 7857.00 167.00 365
2008 JOHN D OIL & GAS COMPANY 6227.00 163.00 365
2009 JOHN D OIL & GAS COMPANY 3872.00 58.00 365
2010 JOHN D OIL & GAS COMPANY 4791.00 92.00 365
2011 JOHN D OIL & GAS COMPANY 5411.00 90.00 365
2012 JOHN D OIL & GAS COMPANY 5309.00 98.00 366
2013 JOHN D OIL & GAS COMPANY 5378.00 192.00 365
2014 JOHN D OIL & GAS COMPANY 4607.00 19.00 365
2015 JOHN D OIL & GAS COMPANY 3274.00 19.00 365
2016 DAVID OIL COMPANY LLC 793.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 620 256
2007 JOHN D OIL & GAS COMPANY Brine 615 365
2008 JOHN D OIL & GAS COMPANY Brine 400 365
2009 JOHN D OIL & GAS COMPANY Brine 160 365
2010 JOHN D OIL & GAS COMPANY Brine 320 365
2011 JOHN D OIL & GAS COMPANY Brine 320 365
2012 JOHN D OIL & GAS COMPANY Brine 240 366
2013 JOHN D OIL & GAS COMPANY Brine 130 365
2014 JOHN D OIL & GAS COMPANY Brine 0 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-108502400 2015-3-3 0:00:0 UP No Violations 0.50
-1174392914 2009-11-5 0:00: PL No Violations
-1700277679 2017-9-1 0:00:0 UP No Violations 0.50
-1893065808 2012-12-17 0:00 UP No Violations
-322007210 2014-12-17 0:00 UP No Violations
-501626801 2006-2-6 0:00:0 DD No Violations
0108502400 2015-03-03 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead plunger lift system, mechanical separator, and battery are located in separate, chain-link enclosures which are locked. Connections and fittings are secure and free from signs of leakage or problems. Load-outs are plugged and secure. Signage is present. Process safety equipment is use. I did not observe any evidence of impact relating to on-going production activity.
0146821713 2017-07-18 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice. At the time of the previous inspection, I had noted the following: the tank load lines were not secured with locks as required. I also had noted that the 210-barrel tank had several corrosion holes that have perforated the tank wall rendering the tank integrity not intact. At the time of this inspection, the noted deficiencies remained unchanged. I contacted well tender John Magnussen who indicated that the deficiencies are being tended to as they are able.
0322007210 2014-12-17 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and battery are located behind a commercial facility on Tyler Blvd. The enclosure gates are secure and fittings and connections are free from signs of leakage. Signage is present but remains obscured behind the enclosure fence. I notified Tim Reilly with John D Oil regarding the need to move the ID to a visible location.
0501626801 2006-02-06 Drill / Deepen / Reopen No Violations drilling
0668239562 2016-02-17 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. At the time of my inspection I observed the following elements: a wellhead with mechanical plunger lift system, mechanical separator, and tank battery comprised of one 210-barrel steel production tank, and one 100-barrel, steel brine tank. The battery and wellhead were enclosed in separate chain-link enclosures which were locked and secure. Fittings and connections at the wellhead and battery were secure and free from signs of leakage or problems with the following exception: the tank load lines were not secured with locks as required. I also noted that the 210-barrel tank has several corrosion holes that have perforated the tank wall rendering the tank integrity not intact. The owner must remedy the following by 04/08/2016: secure the load-line valves with locks and remove the 210-barrel tank from service. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1174392914 2009-11-05 Preliminary Restoration No Violations Preliminary restoration passed inspection.
1211763604 2017-03-09 UrbanProduction Wells No Violations I inspected this production well as a follow-up to a previous inspection and associated Compliance Notice issued for the following deficiencies; missing locks on load-lines and numerous, perforating holes in the production tank. At the time of this inspection the noted issues remained. I contacted John Magnussen with David Oil and he reported that they are not producing into the production tank with holes. He reported that they are addressing the issues as they are able.
146821713 2017-7-18 0:00: UP No Violations 0.50
150532189 2019-8-7 0:00:0 UP No Violations
1517409821 2018-01-31 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and the 210-barrel production tank was severely corroded with numerous holes that had rendered it unusable. At the time of this inspection, I observed the following: there were no locks at the load-line valves and the rusted tank remained in place. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. The owner has made previous pledges to take action on these deficiencies but there were no changes to date.
1546286695 2017-12-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and the 210-barrel production tank was severely corroded with numerous holes that had rendered it unusable. At the time of this inspection, I observed the following: there were no locks at the load-line valves and the rusted tank remained in place. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
1593182487 2020-6-26 0:00: UP No Violations
1594307670 2020-7-9 0:00:0 UP No Violations
1595343739 2020-7-21 0:00: UP No Violations
1597946546 2020-8-20 0:00: UP No Violations
1700277679 2017-09-01 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the production tank was observed to be rusted and failed integrity, the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1744703755 2013-09-10 UrbanProduction Wells No Violations The producing unit consists of a wellhead with mechanical plunger lift system and aboveground storage tank battery. The battery, separator, and wellhead are in separate chain-link enclosures. The battery is comprised of 1 210-barrel steel production tank, 1 100-barrel steel brine tank, and separator unit. The spacing between the battery tanks is in compliance. There is adequate secondary containment. There is no visible ID sign outside of the battery. There is an approximate 30 by 40 area denuded of any vegetation which still remains from the drilling operations for this well. This area must be restored.
1893065808 2012-12-17 UrbanProduction Wells No Violations The unit is comprised of a two-tank battery (1 210-barrel production and 1 100-barrel brine) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate chain-link enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The gates are locked.
244873304 2020-6-3 0:00:0 UP No Violations
668239562 2016-2-17 0:00: UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0668239562 US-OH-127568 2016-04-27 LOCKS
0668239562 US-OH-127569 2016-04-27 Well operation causing pollution and contamination