X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21174

Well Details

Well ID: 34-085-21174
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: PENFIELD P
License Status: Producing
License Date: 2005-10-19
Spud Date: 2006-01-27
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2006-02-03
Well Total Depth: 3270.00 ft
Configuration: Vertical
Latitude: 41.620000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-10-19 Proposed Formations:CLINTON, Issued Date:10/19/2005, Expired Date:10/19/2006 6:00:00 AM, Drilling unit acres:23, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-01-27 RBDMS Rec
Completed 2006-02-03 RBDMS Rec
Reached Total Depth 2006-02-03 RBDMS Rec
Completion Report Received 2006-09-01 RBDMS Rec
Construction Permit Expires 2006-10-19 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-11-29 3038 3096 71
3038 3096 71
3038 3096 71

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 78000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION 8340.00 0.00 365
2008 ALLIANCE PETROLEUM CORPORATION 13105.00 0.00 365
2009 ALLIANCE PETROLEUM CORPORATION 8298.00 44.00 365
2010 ALLIANCE PETROLEUM CORPORATION 6056.00 0.00 365
2011 ALLIANCE PETROLEUM CORPORATION 6049.00 0.00 365
2012 ALLIANCE PETROLEUM CORPORATION 4044.00 18.00 366
2013 ALLIANCE PETROLEUM CORPORATION 3217.00 0.00 365
2014 ALLIANCE PETROLEUM CORPORATION 3717.00 0.00 365
2015 ALLIANCE PETROLEUM CORPORATION 2613.00 45.00 365
2016 ALLIANCE PETROLEUM CORPORATION 1962.00 32.00 365
2017 ALLIANCE PETROLEUM CORPORATION 1657.00 0.00 365
2018 ALLIANCE PETROLEUM CORPORATION 1004.00 49.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 481 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 491 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 457 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 182 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 281 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 80 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-198305447 2009-11-9 0:00: PW No Violations
-2119567787 2018-2-16 0:00: UP No Violations 0.50
-643025508 2017-4-17 0:00: UP No Violations 1.00
0198305447 2009-11-09 Production Wells No Violations There were no violations at the time of inspection.
0643025508 2017-04-17 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I noted the following: the dedicated-gravel-paved lease road was dry, well drained and passable. The areas surrounding the wellhead and battery were comprised of meadow grass and other wild vegetation, with piles of debris and other material storage presumed to be from the existing landowner. The wellhead and tank battery were in separate, wooden enclosures. I noted the following deficiencies: the battery enclosure was partially missing. I notified Alliance about the need for maintenance at the enclosure.
0657463028 2014-08-07 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 02/03/2006. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system. The wellhead and battery are located in a wooded area south of I-90, and adjacent to residential homes to the south . The well and battery are accessed via a dedicated access road, which travels east from River Road. The battery is comprised of 1 steel 100-barrel low-boy production tank, 1 25-barrel poly brine tank, and horizontal separator. Spacing from well to battery, and spacing of elements within the battery meet regulations. The wellhead and battery are in separate, wooden stockade-style fence enclosures. Portions of the battery enclosure are missing. The load-outs are bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead. Process safety equipment (low-pressure relief valve, carbon filter, and spark arrestor) is present. No problems requiring attention at the time of this inspection.
1149096473 2006-02-01 Drill / Deepen / Reopen No Violations on site to check distance from property line to well; used range finder from property line to well showed 111 yds (333)

also landowner complaining about port-Jon to close to Property line company said they will move it.I advised landowner that they only need 300 from unit line to well. Case Closed #06002

1843454040 2006-10-20 Preliminary Restoration No Violations
1914848021 2006-02-06 Drill / Deepen / Reopen No Violations on site to check measurment to property line over 300 to well

NO VIOLATION

2119567787 2018-02-16 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I noted the following: the dedicated-gravel-paved lease road was dry, well drained and passable. The areas surrounding the wellhead and battery were comprised of meadow grass and other wild vegetation, with piles of debris and other material storage presumed to be from the existing landowner. The wellhead and tank battery were in separate, wooden enclosures. I noted the following deficiencies: the battery enclosure was partially missing. I notified Alliance about the need for maintenance at the enclosure. Matt Postelwaite indicated that mitigation would be made as soon as possible.
657463028 2014-8-7 0:00:0 UP No Violations

For data sources see[9]

References