X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21168

Well Details

Well ID: 34-085-21168
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: DAVID R HILL INC
Well Pad ID:
Farm/Lease Name: PAINESVILLE COUNTRY CLUB
License Status: Producing
License Date: 2005-08-10
Spud Date: 2006-02-26
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-02-23
Well Total Depth: 3336.00 ft
Configuration: Vertical
Latitude: 41.700000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-08-10 Proposed Formations:CLINTON, Issued Date:8/10/2005, Expired Date:8/10/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EOUT
Completed 2006-02-23 RBDMS Rec
Reached Total Depth 2006-02-23 RBDMS Rec
Original Spud 2006-02-26 RBDMS Rec
Completion Report Received 2006-08-01 RBDMS Rec
Construction Permit Expires 2006-08-10 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-10-20 3179 3215 71
3179 3215 71
3179 3215 71

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 80000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 DAVID R HILL INC 3184.00 370.00 183
2007 DAVID R HILL INC 3769.00 389.00 365
2008 DAVID R HILL INC 1548.00 162.00 365
2009 DAVID R HILL INC 1048.00 117.00 365
2010 DAVID R HILL INC 906.00 115.00 365
2011 DAVID R HILL INC 653.00 96.00 365
2012 DAVID R HILL INC 540.00 0.00 366
2013 DAVID R HILL INC 189.00 45.00 365
2014 DAVID R HILL INC 34.00 0.00 365
2015 DAVID R HILL INC 0.00 24.00 365
2016 DAVID R HILL INC 72.00 0.00 365
2017 DAVID R HILL INC 374.00 0.00 365
2018 DAVID R HILL INC 300.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 DAVID R HILL INC Brine 1357 183
2007 DAVID R HILL INC Brine 2461 365
2008 DAVID R HILL INC Brine 1124 365
2009 DAVID R HILL INC Brine 724 365
2010 DAVID R HILL INC Brine 567 365
2011 DAVID R HILL INC Brine 280 365
2012 DAVID R HILL INC Brine 373 366
2013 DAVID R HILL INC Brine 0 365
2014 DAVID R HILL INC Brine 41 365
2015 DAVID R HILL INC Brine 20 365
2016 DAVID R HILL INC Brine 0 365
2017 DAVID R HILL INC Brine 0 365
2018 DAVID R HILL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1819734267 2009-10-26 0:00 PL No Violations
-1976504610 2015-3-6 0:00:0 UP No Violations 1.00
-628928192 2013-7-15 0:00: UL No Violations
0283430645 2016-01-26 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and battery are located within the confines of the Painesville Country Club. Access to the well is afforded by a short, unpaved access road which is also used as a roadway for maintenance and groundskeeping for the golf course. The battery is located on the east side of the groundskeepers maintenance area. The well is located farther to the west. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system, a tank battery comprised of one 100-barrel steel production tan, one 40-barrel poly brine tank, and separator. The well and battery were in separate chain-link enclosures and were locked and secure. The load-outs were bull-plugged and secure. Secondary containment is intact. I walked the areas surrounding both the wellhead and tank battery and did not observe any evidence of impact or problems associated with the production activity.
0314725885 2019-04-08 UrbanProduction Wells No Violations I conducted an inspection on this well. The well was equipped with a plunger lift assembly and not in production, at the time of this inspection. The gate valve on the tubing was closed. The 2 inch valve on the flow line was open and the 2 inch domestic line off the 4.5 inch casing was open. The domestic line was equipped with two regulators, a drip bottle and meter. The well was fenced with identification. The diked tank battery was comprised of one 100 BBL tank, one 25 BBL poly tank and a mechanical separator. The load out lines were secure with locks and the tank battery was fenced with a locked man door. There was legible identification present at the tank battery and the lease access was stable.
0628928192 2013-07-15 UrbanPreliminary Restoration No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 140-barrel production tank, one steel 20-barrel brine tank, mechanical separator, and metering run.. The unit ID is present and meets requirements. The loadouts are locked. The battery secondary containment is good. The wellhead and battery are in separate chain-link enclosures. Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills.
0932436492 2017-08-01 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The wellhead and battery are in a clearing on the east side of the gold course. The fittings and connections were secure with the following exception: the load-line valves were not locked. The area was otherwise free from signs of problems or leakage. The areas surrounding the well and battery were comprised of grassy vegetation. I walked the areas surrounding the well and battery and found no signs of impact or degradation to the natural greenscape. I contacted David Hill about the need for locks and he indicated that it would be taken care of ASAP.
1819734267 2009-10-26 Preliminary Restoration No Violations Preliminary restoration meets the requirements of 1509.072 ORC.
1976504610 2015-03-06 UrbanProduction Wells No Violations I inspected the producing well as part of routine inspection activity. The well and battery are located next to the maintenance shed on the west side of the clubhouse. The wellhead and battery are located in separate chain-link enclosures. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or other problems. The load-out is plugged and secure but needs a lock. Evaluation of drainage and other surficial features is limited due to snow cover. I notified the well tender regarding the need for a lock. I did not observe any evidence of impact relating to on-going production activity.
283430645 2016-1-26 0:00: UP No Violations 0.50
314725885 2019-4-8 0:00:0 UP No Violations 0.50
932436492 2017-8-1 0:00:0 UP No Violations 0.50
968931692 2020-9-8 0:00:0 UP No Violations

For data sources see[9]

References