X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21159

Well Details

Well ID: 34-085-21159
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: ANDREWS SCHOOL/LORETO UNIT
License Status: Producing
License Date: 2005-06-15
Spud Date: 2005-08-01
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2005-08-10
Well Total Depth: 3222.00 ft
Configuration: Vertical
Latitude: 41.630000
Longitude: -81.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-06-15 Proposed Formations:CLINTON/MEDINA, Issued Date:6/15/2005, Expired Date:6/15/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-08-01 RBDMS Rec
Completed 2005-08-10 RBDMS Rec
Reached Total Depth 2005-08-10 RBDMS Rec
Construction Permit Expires 2006-06-15 RBDMS Rec
Completion Report Received 2006-08-09 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-10-26 3110 3178 55
3110 3178 55
3110 3178 55

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 70000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 ALLIANCE PETROLEUM CORPORATION 3307.00 121.00 306
2007 ALLIANCE PETROLEUM CORPORATION 3218.00 0.00 365
2008 ALLIANCE PETROLEUM CORPORATION 1613.00 0.00 365
2009 ALLIANCE PETROLEUM CORPORATION 692.00 0.00 365
2010 ALLIANCE PETROLEUM CORPORATION 436.00 67.00 365
2011 ALLIANCE PETROLEUM CORPORATION 516.00 38.00 365
2012 ALLIANCE PETROLEUM CORPORATION 741.00 22.00 366
2013 ALLIANCE PETROLEUM CORPORATION 705.00 52.00 365
2014 ALLIANCE PETROLEUM CORPORATION 417.00 44.00 365
2015 ALLIANCE PETROLEUM CORPORATION 557.00 22.00 365
2016 ALLIANCE PETROLEUM CORPORATION 589.00 70.00 365
2017 ALLIANCE PETROLEUM CORPORATION 883.00 21.00 365
2018 ALLIANCE PETROLEUM CORPORATION 825.00 23.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 ALLIANCE PETROLEUM CORPORATION Brine 0 306
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 173 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 182 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 234 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 193 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 150 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 79 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2009682620 2010-11-15 0:00 PW No Violations
-22428954 2013-7-16 0:00: UP No Violations
-889980727 2019-7-1 0:00:0 UP No Violations
0022428954 2013-07-16 UrbanProduction Wells No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with two steel 140-barrel production tanks, one steel 20-barrel brine tank, mechanical separator, and metering run.. The unit ID is present and meets requirements. The loadouts are bull-plugged. The battery secondary containment is good. The wellhead and battery are in separate chain-link enclosures. Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills. The wellhead area inside the enclosure is overgrown with weeds making inspection of the valve tree difficult. I contacted Bruce Close with Alliance and advised him of the need for weed maintenance.
0644099083 2017-03-17 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following: a wellhead with plunger lift system and associated battery located on the grounds of the Andrews Osborne school, at the south side of the school property. The entry and initial portion of the access road is shared with the school facility, and was in good condition. There is a dedicated, gravel-paved access road that continues south from the equestrian area, and provides access to two additional producing wells (#2-1160 and #2-1179). The dedicated portion of the access road was well drained and in good condition. Access gates and load-lines were locked and secure. Tank lids were closed and secure. I walked the areas around the wellhead and battery and found the natural conditions intact with no signs of impact or problems.
0982201229 2005-08-18 Drill / Deepen / Reopen No Violations
1056629246 2020-7-9 0:00:0 UP No Violations
1122998429 2005-07-25 Drill / Deepen / Reopen No Violations HB278 persite review
1124814572 2005-08-02 Drill / Deepen / Reopen No Violations Rig check
1389613521 2006-11-29 Preliminary Restoration No Violations
2009682620 2010-11-15 Production Wells No Violations There were no violations at the time.
644099083 2017-3-17 0:00: UP No Violations 0.50
982201229 2005-8-18 0:00: DD No Violations

For data sources see[9]

References