If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21142 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.62,"lon":-81.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: REBEL | |
License Status: Producing | |
License Date: 2005-01-14 | |
Spud Date: 2005-06-07 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2005-06-13 | |
Well Total Depth: 3385.00 ft | |
Configuration: Vertical | |
Latitude: 41.620000 | |
Longitude: -81.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-01-14 | Proposed Formations:CLINTON, Issued Date:1/14/2005, Expired Date:1/14/2006 6:00:00 AM, Drilling unit acres:28, Proposed Well Type:OG, Proposed Well Class:EOUT |
Original Spud | 2005-06-07 | RBDMS Rec |
Completed | 2005-06-13 | RBDMS Rec |
Reached Total Depth | 2005-06-13 | RBDMS Rec |
Completion Report Received | 2005-09-06 | RBDMS Rec |
Construction Permit Expires | 2006-01-14 | RBDMS Rec |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-11-03 | 3146 | 3156 | 13 |
3146 | 3156 | 13 | |
3146 | 3156 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 417 Bbl | 90000 | 500 GALLONS HCL ACID & 514M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | GREAT PLAINS EXPLORATION LLC | 2138.00 | 0.00 | 160 |
2006 | GREAT PLAINS EXPLORATION LLC | 7053.00 | 0.00 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | 3850.00 | 35.00 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | 2343.00 | 57.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 2068.00 | 0.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 2093.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 2482.00 | 0.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 2198.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 2266.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 2171.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 1348.00 | 0.00 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | 1232.00 | 0.00 | 304 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 160 |
2006 | GREAT PLAINS EXPLORATION LLC | Brine | 520 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 540 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 400 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 450 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 125 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1046194408 | 2005-6-6 0:00:0 | DD | No Violations | |
-1340052826 | 2009-11-9 0:00: | PW | No Violations | |
-1456507389 | 2005-7-8 0:00:0 | DD | No Violations | |
-1460197429 | 2005-10-14 0:00 | PL | No Violations | |
-2147331746 | 2005-7-6 0:00:0 | DD | No Violations | |
-926285983 | 2005-11-7 0:00: | PL | No Violations | |
0535523303 | 2017-04-17 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves. At the time of this inspection, I observed the following: The load-line valves were not secured with locks. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages. |
0561631471 | 2005-06-29 | Drill / Deepen / Reopen | No Violations | dewating pits to close |
0919866096 | 2005-06-09 | Drill / Deepen / Reopen | No Violations | drilling |
0926285983 | 2005-11-07 | Preliminary Restoration | No Violations | |
0969540627 | 2005-07-25 | Production Wells | No Violations | Area gradeed ready for seeding |
1046194408 | 2005-06-06 | Drill / Deepen / Reopen | No Violations | surface |
1119975982 | 2005-06-13 | Completion Testing | No Violations | circulating to run 4.5 |
1340052826 | 2009-11-09 | Production Wells | No Violations | No violations were found at the time of inspection. |
1350398302 | 2012-08-07 | UrbanProduction Wells | No Violations | The unit is comprised of a two-tank battery (1, 210-barrel production and 1, 100-barrel brine) and a wellhead with mechanical lift. The mechanical separator is housed within a separate fenced enclosure. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05. Unit identification is present and legible at the tank battery. The tank battery dike is acceptable. I did not observe any leaks, spills, or other signs of contamination. The gates at the tank battery, well, and mechanical separator have locks. Due to the residential location, the tanks should have spark arrestors, low-pressure relief valves, and charcoal canister filter in accordance with HB 278. I called Jim Willimans and he said he would have this remedied within the next week. |
1360801827 | 2017-12-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load lines were not locked and secure. At the time of this inspection, I observed the following: the load-line valves remained unlocked. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
1456507389 | 2005-07-08 | Drill / Deepen / Reopen | No Violations | well being logged |
1456755211 | 2016-02-29 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following elements: one wellhead with mechanical plunger lift system in a board-on-board enclosure, one mechanical separator in a board-on-board enclosure, a tank battery comprised of one 210-barrel steel tank and one 100-barrrel steel tank with associated fittings and tubular connections in a board-on-board enclosure. I observed the system fittings and connections to be secure and free from leakage. The tank lids were closed and secure. Spark arrestor, low-pressure relief valve, and carbon filter were present. Secondary containment was intact. I walked the areas surrounding the wellhead and battery and did not observe any evidence of impact or erosional deficits. Access to the well is afforded by the shared-use parking and drive area utilized by Willoughby City. I observed the following safety deficiency: the wellhead enclosure gate was not locked and secure, the load-lines valve was not locked as required. The owner must remedy the following by 03/31/2016: secure the enclosure gates and load-lines with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1460197429 | 2005-10-14 | Preliminary Restoration | No Violations | |
1505225330 | 2017-09-12 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress. |
1551722666 | 2019-03-04 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 1456755211, regarding locks needing installed on the production tank valves. At the time of this inspection, the tank valves on the production tanks still needed locks. I contacted Rockefeller Oil Company office and discussed the need for installation of locks on the tank valves. |
1891823694 | 2011-07-07 | UrbanProduction Wells | No Violations | Rabbit catcher in good repair. Fencing and dike in compliance. ID sign posted. Vent hatches installed and closed. No violations at this time. |
2039953860 | 2018-02-16 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load lines were not locked and secure. At the time of this inspection, I observed the following: the load-line valves remained unlocked. I have contacted and met with the owner regarding these deficiencies. The owner has pledged to remedy the problems, but no changes were noted at the time of this inspection. The deficiencies remained. |
2045133319 | 2005-08-18 | Production Wells | No Violations | |
2147331746 | 2005-07-06 | Drill / Deepen / Reopen | No Violations | drilling 2586 |
535523303 | 2017-4-17 0:00: | UP | No Violations | 0.50 |
561631471 | 2005-6-29 0:00: | DD | No Violations | |
919866096 | 2005-6-9 0:00:0 | DD | No Violations | |
969540627 | 2005-7-25 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1456755211 | US-OH-113229 | 2016-04-27 | LOCKS |
For data sources see[9]