X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21131

Well Details

Well ID: 34-085-21131
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Madison Township
Operator Name: MILNER LAKE ENERGY LLC
Well Pad ID:
Farm/Lease Name: COOK UNIT
License Status: Producing
License Date: 2004-12-01
Spud Date: 2005-01-03
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-01-08
Well Total Depth: 3446.00 ft
Configuration: Vertical
Latitude: 41.720000
Longitude: -81.070000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-12-01 Proposed Formations:CLINTON, Issued Date:12/1/2004, Expired Date:12/1/2005 6:00:00 AM, Drilling unit acres:52.14, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-01-03 RBDMS Rec
Completed 2005-01-08 RBDMS Rec
Reached Total Depth 2005-01-08 RBDMS Rec
Completion Report Received 2005-03-11 RBDMS Rec
Construction Permit Expires 2005-12-01 RBDMS Rec
Change of Owner 2010-01-25 Operator changed from 3847, HALL & HORNING SERV INC to 8602, ALLIED OIL FIELD SERVICES LTD
Change of Owner 2016-03-10 Operator changed from 8602, ALLIED OIL FIELD SERVICES LTD to 9617, MILNER LAKE ENERGY, LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-05-31 3232 3284 92
3232 3284 92
3232 3284 92

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1200 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 HALL & HORNING SERV INC 765.00 77.00 291
2006 HALL & HORNING SERV INC 2042.00 273.00 365
2007 HALL & HORNING SERV INC 1262.00 203.00 365
2008 HALL & HORNING SERV INC 1019.00 144.00 366
2009 ALLIED OIL FIELD SERVICES LTD 672.00 0.00 72
2010 ALLIED OIL FIELD SERVICES LTD 775.00 83.00 365
2011 ALLIED OIL FIELD SERVICES LTD 647.00 61.00 365
2012 ALLIED OIL FIELD SERVICES LTD 741.00 78.00 366
2013 ALLIED OIL FIELD SERVICES LTD 470.00 96.00 365
2014 ALLIED OIL FIELD SERVICES LTD 402.00 0.00 365
2015 ALLIED OIL FIELD SERVICES LTD 260.00 85.00 365
2016 MILNER LAKE ENERGY LLC 384.00 0.00 365
2017 MILNER LAKE ENERGY LLC 315.00 0.00 365
2018 MILNER LAKE ENERGY LLC 237.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 HALL & HORNING SERV INC Brine 1669 291
2006 HALL & HORNING SERV INC Brine 4110 365
2007 HALL & HORNING SERV INC Brine 0 365
2008 HALL & HORNING SERV INC Brine 2005 366
2009 HALL & HORNING SERV INC Brine 0 195
2010 ALLIED OIL FIELD SERVICES LTD Brine 1669 365
2011 ALLIED OIL FIELD SERVICES LTD Brine 557 365
2012 ALLIED OIL FIELD SERVICES LTD Brine 1249 366
2013 ALLIED OIL FIELD SERVICES LTD Brine 1342 365
2014 ALLIED OIL FIELD SERVICES LTD Brine 1045 365
2015 ALLIED OIL FIELD SERVICES LTD Brine 81 365
2016 ALLIED OIL FIELD SERVICES LTD Brine 27 30
2017 MILNER LAKE ENERGY LLC Brine 166 365
2018 MILNER LAKE ENERGY LLC Brine 210 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-143665515 2016-4-14 0:00: UP No Violations 1.00
-504539708 2013-6-18 0:00: UP No Violations
-522164607 2009-9-1 0:00:0 PL No Violations
-999439766 2014-10-29 0:00 UP No Violations
0081565703 2005-01-03 Drill / Deepen / Reopen No Violations surface
0143665515 2016-04-14 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: one wellhead with pump jack system located in an open area on a farmstead. Fittings and connections at the wellhead were secure with the following exception: oil and other produced fluids have leaked from the stuffing box fitting and impacted an approximate 50 square foot area around the wellhead. The battery is comprised of 210-barrel production tanks, and one 50-barrel brine tank, with separator with associated appurtenances. Load lines were plugged and secure. Secondary containment was intact. Signage was present. Production reports were current. The owner must take the following action before 05/20/2016: remove impacted soil, grade and re-seed the area, repair/replace stuffing box seals and packing. Contact Inspector Stephen Tompkins at 330-907-4647 regarding this Compliance Notice.
0504539708 2013-06-18 UrbanProduction Wells Violations Noted Previously I had inspected this producing unit and observed oily staining on the production tank and in the gravel material around the tank. I had indicated to the owner/operator the need to clean the oil. Upon this visit, I discovered that another spill or overfill of the production tank had occurred. Approximately 50% of the granular fill inside the secondary containment is saturated with free-phase oil. There are three areas radiating from the north side of the containment dike where oil has migrated through the dike and killed the grass. These areas extend up to 30 feet to the north. Absorbent peat moss material has been placed inside the dike and along the oily migration pathways to the north. I contacted Pierre Delafransisco with Allied Oil Field Serv. and advised him to shut-in the unit and begin remediation of the oil spill. I indicated that remediation should included removal of the oil-impacted soil outside the dike, and removal and replacement of the oil and oil-impacted granular fill inside the dike. Also the areas of dead grass would need to be re-seeded. He indicated that work would commence by mid-week next week.
0522164607 2009-09-01 Preliminary Restoration No Violations Preliminary restoration meets the requirements of 1509.072 ORC.
0999439766 2014-10-29 UrbanProduction Wells No Violations I inspected this location has part of follow-up to an previous compliance notice relating to a release of oil form this unit. The area on the north side of the tank battery dike which had been impacted with oil has been cleaned and seeded. The impacted soil pile has been removed. No further action is needed with regards to the former oil spill.
1141090144 2017-09-19 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: there had been an area of stressed vegetation/brine scald near the wellhead . At the time of this inspection, the area is regaining vegetation and so the noted deficiency had been mitigated. I walked the areas surrounding the well and battery and found no signs of problems or impacts.
1202950732 2014-10-07 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to an earlier incident in which oil was released from the 210-barrel production tank. The pile of impacted soil remains on location. The impacted area has not been re-seeded as required. Allied reports that these items will be remedied as soon as possible.
1372699182 2013-07-01 UrbanProduction Wells No Violations I visited the site pursuant to my earlier discussions with Allied Oil Field Services. Based on my observations today, I advised that there is still a significant amount of free oil in the dike, within the gravel. The dike is failing in several places allowing oil to migrate down-gradient. I recommended that an interceptor trench be dug on the down-gradient side of the dike to prevent further migration. More of the oily gravel needs to be removed and replaced.
1373389435 2013-07-09 UrbanProduction Wells No Violations The previously documented and observed oil leaking through the dike is continuing. Allied placed two oil sorbent booms but oil is leaking through the dike. I contacted Allied and advised them that immediate action would be required.
1373897173 2013-07-15 UrbanProduction Wells No Violations Oil impacted gravel material has been removed from the secondary containment area. A small cut-off trench has been dug and a sorbent boom has been placed in it. Allied also added a sealable dike drain constructed of 1.5-inch PVC. Ive discussed with Allied the need for further mitigation and restoration consisting of reseed of the areas down-gradient of the dike with dead grass.
2086243103 2013-08-28 UrbanProduction Wells No Violations The oily impact inside the diked area and down-gradient of the tank battery has been mitigated. There is a small amount of free-phase oil in the battery. There is a newly-placed dike drain which was left open and unattended. The impacted areas outside the dike still need to be re-seeded, and there is a stockpile of impacted soil still waiting for off-site disposal.
81565703 2005-1-3 0:00:0 DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0143665515 US-OH-112734 2017-10-23 9-1-07 Well operation causing pollution and contamination
0504539708 US-OH-125505 2013-08-16 Well operation causing pollution and contamination

For data sources see[9]