34-085-21091

Well Details

Well ID: 34-085-21091
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Madison Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: LAKE COUNTY ROD & GUN CLUB
License Status: Producing
License Date: 2003-12-03
Spud Date: 2004-01-08
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-01-14
Well Total Depth: 3409.00 ft
Configuration: Vertical
Latitude: 41.720000
Longitude: -81.050000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-12-03 Proposed Formations:CLINTON, Issued Date:12/3/2003, Expired Date:12/2/2004 6:00:00 AM, Drilling unit acres:76.502, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-01-08 RBDMS Rec
Completed 2004-01-14 RBDMS Rec
Reached Total Depth 2004-01-14 RBDMS Rec
Completion Report Received 2004-02-17 RBDMS Rec
Construction Permit Expires 2004-12-02 RBDMS Rec
Change of Owner 2015-07-16 Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-04-14 3205 3240 39
3205 3240 39
3205 3240 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1482 Bbl 70000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2004 BROAD STREET ENERGY COMPANY 698.00 558.00 325
2005 BROAD STREET ENERGY COMPANY 977.00 309.00 365
2006 BROAD STREET ENERGY COMPANY 689.00 124.00 365
2007 BROAD STREET ENERGY COMPANY 304.00 100.00 365
2008 BROAD STREET ENERGY COMPANY 234.00 110.00 365
2009 BROAD STREET ENERGY COMPANY 192.00 54.00 365
2010 BROAD STREET ENERGY COMPANY 134.00 37.00 365
2011 BROAD STREET ENERGY COMPANY 94.00 0.00 365
2012 BROAD STREET ENERGY COMPANY 224.00 0.00 366
2013 BROAD STREET ENERGY COMPANY 288.00 0.00 365
2014 BROAD STREET ENERGY COMPANY 185.00 0.00 365
2015 M & R INVESTMENTS OHIO LLC 61.00 0.00 365
2016 M & R INVESTMENTS OHIO LLC 125.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 289.00 36.00 365
2018 M & R INVESTMENTS OHIO LLC 242.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 BROAD STREET ENERGY COMPANY Brine 0 0
2004 BROAD STREET ENERGY COMPANY Brine 1355 325
2005 BROAD STREET ENERGY COMPANY Brine 799 365
2006 BROAD STREET ENERGY COMPANY Brine 635 365
2007 BROAD STREET ENERGY COMPANY Brine 466 365
2008 BROAD STREET ENERGY COMPANY Brine 387 365
2009 BROAD STREET ENERGY COMPANY Brine 261 365
2010 BROAD STREET ENERGY COMPANY Brine 352 365
2011 BROAD STREET ENERGY COMPANY Brine 284 365
2012 BROAD STREET ENERGY COMPANY Brine 270 366
2013 BROAD STREET ENERGY COMPANY Brine 227 365
2014 BROAD STREET ENERGY COMPANY Brine 224 365
2015 M & R INVESTMENTS OHIO LLC Brine 0 365
2016 M & R INVESTMENTS OHIO LLC Brine 126 365
2017 M & R INVESTMENTS OHIO LLC Brine 0 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1023619642 2016-4-13 0:00: UP No Violations 1.00
-1217164465 2014-3-13 0:00: UP No Violations
-177165220 2013-6-18 0:00: UP No Violations
-729197504 2004-8-19 0:00: PL No Violations
0177165220 2013-06-18 UrbanProduction Wells No Violations The producing unit consists of a wellhead with pump jack and storage tank battery. The wellhead and battery are not enclosed. There is a partially dismantled chain-link enclosure at the battery. The battery is comprised of three above-ground storage tanks (ASTs), 1 140 barrel, 1 100 barrel, and a mechanical separator. The battery is shared with the LC Rod & Gun 5 Unit. The battery is also shared with the Klemenc #1 Unit (20865), but is not identified on the tank battery ID. The tank battery ID is lacking any API #s. I called the pumper (Ron Slother) and advised him about the need for maintenance.
0729197504 2004-08-19 Preliminary Restoration No Violations
1023619642 2016-04-13 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: one wellhead with pump jack system located in a open agricultural field 1,500 feet north of the associated battery (shared with the #2-1092 and the #2-0865). Fittings and connections at the wellhead were secure, with the following exception: The flexible supply line from the well to the pump jack motor was worn, and leaking gas. The battery is comprised of one 210-barrel production tank, and one 100-barrel brine tank, with separator with associated appurtenances. Load lines were plugged and secure. Secondary containment was intact. Signage was present. Production reports were current. I notified M&R Investments about the leaking gas supply line. I noted that the signage at the wellhead has not been changed to reflect the new owner. I notified the owner about the need to update the signage at the wellhead.
1049920048 2013-02-11 UrbanProduction Wells No Violations The producing unit consists of the following: a wellhead with pumpjack system, a 4 tank battery (2 210 barrel, 2 100 barrel), 3 mechanical separators, and associated piping and mechanicals. The tank battery is shared with the #1092 and #0865 units. The tank battery is partially enclosed in a 6-foot chainlink fence. The tank battery secondary containment is adequate. The unit spacing is in accordance with the rule. I did not observe any signs of leaks, releases, or other problems. The unit ID does not indicate permit numbers. There is no ID at the wellhead. I called Matt Sisson and notified him of the need for ID.
1217164465 2014-03-13 UrbanProduction Wells No Violations The unit is producing. The unit identification placard is not compliant. The placard at the tank battery is missing the API #s. The placard indicates the Lake County Rod & Gun Club #4 and #5 produce into the battery. Inspection indicates the Klemenc (#20865) is also producing into this battery but not identified. I will contact Broadstreet about adressing the issue.
1469543205 2015-03-25 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead and are located on a larger farmstead parcel with access via an unpaved, dedicated access road from E. Loveland Road. The road is mostly grown-over with field grass but is passable when dry. The wellhead is comprised of a pump jack system. Fittings and connections are secure. The tank battery is comprised of 1 210-barrel steel production tanks, 2 100-barrel steel brine tanks and 3 separator units. The battery is shared with the #2-0865 and the #2-1092 wells. Elements of the system are aged and show some signs of minor to moderate corrosion but are intact. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well.
1511284178 2017-11-21 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located on otherwise undeveloped rural property, with the battery located next to the road, and the well beyond the entrance to the right. The battery is shared with the #2-1092 and the #2-0966 wells, located on the same parcel. At the time of this inspection, I found the following: a wellhead pump jack system and associated battery. The fittings and connections were secure and free from leakage or problems. Fittings and connections at the battery were secure. The load-lines were plugged and secure. ID signage was present and at the battery but needed updated and complete API number. The secondary containment was intact with no signs of leakage, spills, or problems. The well was in active production. The chart recorder was active. Production reports were current. Bonding and insurance was in place and current. I notified Bill Fitzmartin about the need for updated signage.

For data sources see[9]