Well Details

Well ID: 34-085-21085
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: ALLIED OIL FIELD SERVICES LTD
Well Pad ID:
Farm/Lease Name: ALLEN FAMILY TRUST UNIT
License Status: Final Restoration
License Date: 2013-05-21
Spud Date: 2003-12-09
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2003-12-12
Well Total Depth: 3106.00 ft
Configuration: Vertical
Latitude: 41.750000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-11-26 Proposed Formations:CLINTON, Issued Date:11/26/2003, Expired Date:11/25/2004 6:00:00 AM, Drilling unit acres:22.96, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2003-12-09 RBDMS Rec
Completed 2003-12-12 RBDMS Rec
Reached Total Depth 2003-12-12 RBDMS Rec
Completion Report Received 2004-08-05 RBDMS Rec
Change of Owner 2010-01-25 Operator changed from 3847, HALL & HORNING SERV INC to 8602, ALLIED OIL FIELD SERVICES LTD
Plugged/Abandoned 2013-05-15 RBDMS Rec
APP 2013-05-21 Proposed Formations:CLINTON, Issued Date:5/21/2013, Expired Date:5/21/2015 12:00:00 PM, Drilling unit acres:22.96, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2015-05-21 RBDMS Rec
Record Last Modified 2017-10-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-10-06 2894 2963 64
2894 2963 64
2894 2963 64

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2000 Bbl 20000 600 GALLONS SC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 HALL & HORNING SERV INC 0.00 0.00 0
2004 HALL & HORNING SERV INC 5122.00 108.00 339
2005 HALL & HORNING SERV INC 1532.00 0.00 365
2006 HALL & HORNING SERV INC 660.00 28.00 365
2007 HALL & HORNING SERV INC 719.00 32.00 365
2008 HALL & HORNING SERV INC 509.00 0.00 366
2009 HALL & HORNING SERV INC 325.00 0.00 195
2010 ALLIED OIL FIELD SERVICES LTD 578.00 24.00 365
2011 ALLIED OIL FIELD SERVICES LTD 443.00 0.00 365
2012 ALLIED OIL FIELD SERVICES LTD 510.00 0.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 HALL & HORNING SERV INC Brine 0 0
2004 HALL & HORNING SERV INC Brine 1225 339
2005 HALL & HORNING SERV INC Brine 735 365
2006 HALL & HORNING SERV INC Brine 562 365
2007 HALL & HORNING SERV INC Brine 0 365
2008 HALL & HORNING SERV INC Brine 471 366
2009 HALL & HORNING SERV INC Brine 0 195
2010 ALLIED OIL FIELD SERVICES LTD Brine 470 365
2011 ALLIED OIL FIELD SERVICES LTD Brine 404 365
2012 ALLIED OIL FIELD SERVICES LTD Brine 160 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1868747597 2005-7-15 0:00: PL No Violations
0215257949 2010-03-18 Production Wells No Violations There were no violations at the time of inspection.
0567276198 2017-07-18 Final Restoration No Violations I inspected this well location as an evaluation for Final Restoration. The well was plugged and abandoned in 5/2013. At the time of this inspection, the area where the former well had been located has been restored with asphalt paving and the area of the former battery has well-established grass and other vegetation. No further activity is needed. A waiver has been submitted for the sales line, which was left in place. Final Restoration is passed.
0636259401 2004-11-23 Preliminary Restoration No Violations
1124635908 2012-11-28 UrbanProduction Wells No Violations The unit consists of a pumpjack unit in a 6-foot fenced enclosure. The tank battery (TB) consists of 1 210-bbl tank, 1 and mechanical separator. There is not an enclosure at the tb. The spacing is in accordance with the rule. The tank battery dike is adequate. There is a minor leak at the bottom of the production tank. There is no ID at the TB or the pumping unit. I called Cindy Moore of Allied Oil Field Serv., regarding the need for locks on the load-outs, repair of the leak,and missing ID. She indicated that they are beginning to implement the repairs.
1373570469 2013-07-11 Plug / Plug Back No Violations The well was recently plugged, and is awaiting completion of final restoration. The area around the well is re-graded and looks good. There is a 50-barrel poly tank remaining in the area of the former tank battery. There are former supply lines sticking up through the ground next to the former tank battery.
1868747597 2005-07-15 Preliminary Restoration No Violations
215257949 2010-3-18 0:00: PW No Violations
567276198 2017-7-18 0:00: FR No Violations 1.00
636259401 2004-11-23 0:00 PL No Violations

For data sources see[9]