34-085-21078

Well Details

Well ID: 34-085-21078
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Perry Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: ZAMPINI UNIT
License Status: Producing
License Date: 2003-09-05
Spud Date: 2004-02-25
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2004-03-02
Well Total Depth: 3140.00 ft
Configuration: Vertical
Latitude: 41.740000
Longitude: -81.170000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-09-05 Proposed Formations:CLINTON, Issued Date:9/5/2003, Expired Date:9/4/2004 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-02-25 RBDMS Rec
Completed 2004-03-02 RBDMS Rec
Reached Total Depth 2004-03-02 RBDMS Rec
Completion Report Received 2004-04-08 RBDMS Rec
Correction to Well 2004-08-13 UNIT SIZE CHANGED TO 21 ACRES.
Construction Permit Expires 2004-09-04 RBDMS Rec
Change of Owner 2015-07-16 Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-06-09 2931 2953 23
2931 2953 23
2931 2953 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1476 Bbl 70000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 BROAD STREET ENERGY COMPANY 885.00 0.00 275
2005 BROAD STREET ENERGY COMPANY 2965.00 44.00 365
2006 BROAD STREET ENERGY COMPANY 4158.00 79.00 365
2007 BROAD STREET ENERGY COMPANY 3223.00 0.00 365
2008 BROAD STREET ENERGY COMPANY 2608.00 0.00 365
2009 BROAD STREET ENERGY COMPANY 1908.00 58.00 365
2010 BROAD STREET ENERGY COMPANY 1845.00 0.00 365
2011 BROAD STREET ENERGY COMPANY 1692.00 40.00 365
2012 BROAD STREET ENERGY COMPANY 1475.00 0.00 366
2013 BROAD STREET ENERGY COMPANY 1217.00 0.00 365
2014 BROAD STREET ENERGY COMPANY 1024.00 33.00 365
2015 M & R INVESTMENTS OHIO LLC 377.00 0.00 365
2016 M & R INVESTMENTS OHIO LLC 865.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 856.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 759.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 BROAD STREET ENERGY COMPANY Brine 477 275
2005 BROAD STREET ENERGY COMPANY Brine 515 365
2006 BROAD STREET ENERGY COMPANY Brine 355 365
2007 BROAD STREET ENERGY COMPANY Brine 289 365
2008 BROAD STREET ENERGY COMPANY Brine 225 365
2009 BROAD STREET ENERGY COMPANY Brine 196 365
2010 BROAD STREET ENERGY COMPANY Brine 197 365
2011 BROAD STREET ENERGY COMPANY Brine 134 365
2012 BROAD STREET ENERGY COMPANY Brine 164 366
2013 BROAD STREET ENERGY COMPANY Brine 234 365
2014 BROAD STREET ENERGY COMPANY Brine 82 365
2015 M & R INVESTMENTS OHIO LLC Brine 0 365
2016 M & R INVESTMENTS OHIO LLC Brine 145 365
2017 M & R INVESTMENTS OHIO LLC Brine 34 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1236125538 2018-5-9 0:00:0 UP No Violations 1.00
-1327362649 2004-2-25 0:00: DD No Violations
-80211666 2013-9-24 0:00: UP No Violations
0080211666 2013-09-24 UrbanProduction Wells No Violations The producinjg wellhead is currently fitted with a pumpjack system and is producing. There is no identification at the wellhead. The aboveground tank battery is comprised of 2 steel 100-barrel production tanks and 1 steel 50-barrel brine tank. There are three separator units for the three producing wells shared by this battery (#20565, #21078, and #20518). The lids are open on all three tanks. These are required to be cloased when unattended. Production tank #37088 has no lid. The secondary containment dike is low on the south side and not SPCC compliant. There are ID placards at the battery.
0226242629 2018-09-21 UrbanProduction Wells No Violations I inspected this well in repsonse to a complaint in which the complainant had reported that the contact number at the well was not operational. At the time of this inspection, I found the newer signage at the tank battery was accurate and the contact number was functioning. There was older signage at the wellhead that was an older number. I advised the well owner to remove any older, out-dated signage and numbers and he indicated this would be remedied.
0297319914 2004-02-26 Drill / Deepen / Reopen No Violations Surface cementing
0390374451 2017-02-08 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery located on a larger, farm parcel on Shepard Road. Fittings at the wellhead including flow-line connections and stuffing box fittings were secure and free from leakage. The tank battery was comprised of two 100-barrel steel production tanks and one 50-barrel steel brine tank. The battery is shared with the Losely 10 well (#2-0518) and the Horak well (#2-0565). The secondary containment was present and intact. The visible system connections were secure and free from leakage. I walked the areas surrounding both the wellhead and battery which were comprised of a relatively level and open farm field. I did not observe any signs of impact. The unpaved access road was mostly well drained with some pot-holing typical of a shared-use farm road.
1215522027 2004-07-27 Production Wells No Violations tank battery only.
1236125538 2018-05-09 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: Fittings at the wellhead including flow-line connections and stuffing box fittings were secure and free from leakage. The battery is shared with the Losely 10 well (#2-0518) and the Horak well (#2-0565). The secondary containment was present and intact. The visible system connections were secure and free from leakage. I walked the areas surrounding both the wellhead and battery which were comprised of a relatively level and open farm field. I did not observe any signs of impact. The unpaved access road was in acceptable condition.
1286856528 2004-07-27 Preliminary Restoration No Violations
1327362649 2004-02-25 Drill / Deepen / Reopen No Violations Making loaction
226242629 2018-9-21 0:00: UP No Violations 1.00
297319914 2004-2-26 0:00: DD No Violations
387245571 2019-8-6 0:00:0 UP No Violations
390374451 2017-2-8 0:00:0 UP No Violations 0.50

For data sources see[9]