34-085-21065

Well Details

Well ID: 34-085-21065
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: HENDRICKS
License Status: Producing
License Date: 2003-07-01
Spud Date: 2003-10-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2003-10-13
Well Total Depth: 3236.00 ft
Configuration: Vertical
Latitude: 41.700000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-07-01 Proposed Formations:CLINTON, Issued Date:7/1/2003, Expired Date:6/30/2004 6:00:00 AM, Drilling unit acres:46, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2003-10-07 RBDMS Rec
Completed 2003-10-13 RBDMS Rec
Reached Total Depth 2003-10-13 RBDMS Rec
Construction Permit Expires 2004-06-30 RBDMS Rec
Completion Report Received 2004-09-02 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-10-21 2968 2980 13
2968 2980 13
2968 2980 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 400 Bbl 100000 500 GALLONS HCL ACID & 435M SCF NITROGEN

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC 12719.00 69.00 305
2005 GREAT PLAINS EXPLORATION LLC 15783.00 142.00 365
2006 GREAT PLAINS EXPLORATION LLC 9635.00 56.00 365
2007 GREAT PLAINS EXPLORATION LLC 7409.00 38.00 365
2008 GREAT PLAINS EXPLORATION LLC 5588.00 27.00 365
2009 GREAT PLAINS EXPLORATION LLC 6440.00 36.00 365
2010 GREAT PLAINS EXPLORATION LLC 3585.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 3223.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 2723.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 2402.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 6875.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 6198.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 14.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC Brine 0 305
2005 GREAT PLAINS EXPLORATION LLC Brine 140 365
2006 GREAT PLAINS EXPLORATION LLC Brine 320 365
2007 GREAT PLAINS EXPLORATION LLC Brine 420 365
2008 GREAT PLAINS EXPLORATION LLC Brine 320 365
2009 GREAT PLAINS EXPLORATION LLC Brine 240 365
2010 GREAT PLAINS EXPLORATION LLC Brine 320 365
2011 GREAT PLAINS EXPLORATION LLC Brine 240 365
2012 GREAT PLAINS EXPLORATION LLC Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 240 365
2014 GREAT PLAINS EXPLORATION LLC Brine 230 365
2015 GREAT PLAINS EXPLORATION LLC Brine 230 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1837489156 2017-4-19 0:00: UP No Violations 0.50
-400790865 2016-2-16 0:00: UP No Violations 0.50
-559694858 2017-9-6 0:00:0 UP No Violations 0.50
0400790865 2016-02-16 UrbanProduction Wells Violations Noted I inspected this well location as par6t of routine inspection activity. At the time of this inspection I observed the following elements: A wellhead with pump jack system, a mechanical separator, and a tank battery system. The battery and separator are in a chain-link enclosure. Access to the wellhead is via the shared, asphalt-paved driveway. Fittings and connections at the well and battery were secure and free from evidence of problems or leakage. The battery enclosure gate was unlocked. The load-line valves are not secured with locks. There is an unused steel storage tank stored on-site which must be removed. The owner must do the following by 04/04/2016: remove the unused tank, lock the enclosure gates and load line valves. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0473660171 2009-09-28 Preliminary Restoration No Violations Preliminary restoration meets all requirements.
0559694858 2017-09-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were not secured with locks, an unused and discarded tank, located outside the battery, was left at the location. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1308689354 2019-9-3 0:00:0 UP No Violations
1312712864 2017-12-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load lines were not locked and secure, and there had been a discarded tank left on site. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit signage had not been updated since the change of owner that had occurred in 2016 and there was not fencing or enclosure at the wellhead. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
1351522052 2012-10-26 UrbanProduction Wells No Violations The unit consists of a 1-tank battery (TB) with mechanical separator enclosed in a 6-foot chain link fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a pumpjack and is not enclosed. The gates on the enclosures are not locked. The tank battery dike is adequate; however, the brine collection tank is outside the diked area. The access hatch is missing from the brine tank. I called Tim Reilly of Great Plains and advised him about the need for locks and dike containment for the brine tank. I indicated that the items should be addressed by years end.
1802087394 2017-07-11 UrbanProduction Wells No Violations I inspected this producing well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted the following: the tank battery enclosure and load-line valves were unlocked and not secure as required. An unused field tank is sitting discarded near the well. These conditions remain at the time of this inspection. Also, I noted that the ID signage reflects the prior owner and remains not-updated since the transfer of ownership in 12/2016.
1837489156 2017-04-19 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves and a discarded tank outside the containment. At the time of this inspection, I observed the following: The load-line valves were not secured with locks. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). The discarded tank was still on the location. I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages.
2016416574 2020-3-26 0:00: UP No Violations
473660171 2009-9-28 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0400790865 US-OH-124269 2016-04-27 LOCKS
0400790865 US-OH-124270 2016-04-27 OPERATIONMAINTANCE (a-c)

For data sources see[9]

References