If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21048 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.77,"lon":-81.2,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Painesville Township | |
Operator Name: PET PROCESSORS L.L.C | |
Well Pad ID: | |
Farm/Lease Name: P E T PROCESSORS | |
License Status: Producing | |
License Date: 2001-06-27 | |
Spud Date: 2001-06-28 | |
Spud Drilling Contractor: CENTURY WELL SERVICES,INC | |
Final Drill Date: 2001-07-19 | |
Well Total Depth: 2950.00 ft | |
Configuration: Vertical | |
Latitude: 41.770000 | |
Longitude: -81.200000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2001-06-27 | Proposed Formations:CLINTON, Issued Date:6/27/2001, Expired Date:6/27/2002 6:00:00 AM, Drilling unit acres:192.385, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2001-06-28 | RBDMS Rec |
Completed | 2001-07-19 | RBDMS Rec |
Reached Total Depth | 2001-07-19 | RBDMS Rec |
Completion Report Received | 2002-01-10 | RBDMS Rec |
Construction Permit Expires | 2002-06-27 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2002-02-12 | 2807 | 2873 | 28 |
2807 | 2873 | 28 | |
2807 | 2873 | 28 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 785 Bbl | 72000 | 300 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | PET PROCESSORS L.L.C | 2535.00 | 54.00 | 84 |
2002 | PET PROCESSORS L.L.C | 4457.00 | 76.00 | 350 |
2003 | PET PROCESSORS L.L.C | 1801.00 | 36.00 | 346 |
2004 | PET PROCESSORS L.L.C | 1806.00 | 31.00 | 358 |
2005 | PET PROCESSORS L.L.C | 1732.00 | 20.00 | 354 |
2006 | PET PROCESSORS L.L.C | 1451.00 | 0.00 | 287 |
2007 | PET PROCESSORS L.L.C | 921.00 | 0.00 | 240 |
2008 | PET PROCESSORS L.L.C | 1101.00 | 0.00 | 366 |
2010 | PET PROCESSORS L.L.C | 694.00 | 0.00 | 365 |
2011 | PET PROCESSORS L.L.C | 1182.00 | 0.00 | 365 |
2012 | PET PROCESSORS L.L.C | 1271.00 | 0.00 | 366 |
2013 | PET PROCESSORS L.L.C | 999.00 | 33.00 | 365 |
2014 | PET PROCESSORS L.L.C | 1219.00 | 0.00 | 365 |
2015 | PET PROCESSORS L.L.C | 1324.00 | 0.00 | 365 |
2016 | PET PROCESSORS L.L.C | 1313.00 | 22.00 | 345 |
2017 | PET PROCESSORS L.L.C | 1362.00 | 14.00 | 312 |
2018 | PET PROCESSORS L.L.C | 792.00 | 15.00 | 304 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | PET PROCESSORS L.L.C | Brine | 514 | 84 |
2002 | PET PROCESSORS L.L.C | Brine | 817 | 350 |
2003 | PET PROCESSORS L.L.C | Brine | 426 | 346 |
2004 | PET PROCESSORS L.L.C | Brine | 390 | 358 |
2005 | PET PROCESSORS L.L.C | Brine | 265 | 354 |
2006 | PET PROCESSORS L.L.C | Brine | 284 | 287 |
2007 | PET PROCESSORS L.L.C | Brine | 235 | 240 |
2008 | PET PROCESSORS L.L.C | Brine | 163 | 366 |
2010 | PET PROCESSORS L.L.C | Brine | 80 | 365 |
2011 | PET PROCESSORS L.L.C | Brine | 302 | 365 |
2012 | PET PROCESSORS L.L.C | Brine | 298 | 366 |
2013 | PET PROCESSORS L.L.C | Brine | 71 | 365 |
2014 | PET PROCESSORS L.L.C | Brine | 155 | 365 |
2015 | PET PROCESSORS L.L.C | Brine | 309 | 365 |
2016 | PET PROCESSORS L.L.C | Brine | 25 | 345 |
2017 | PET PROCESSORS L.L.C | Brine | 54 | 312 |
2018 | PET PROCESSORS L.L.C | Brine | 31 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1192004314 | 2009-4-6 0:00:0 | PW | No Violations | |
-1295676188 | 2005-2-15 0:00: | PW | No Violations | |
-1874624722 | 2006-11-2 0:00: | PW | No Violations | |
-869150884 | 2011-12-27 0:00 | SW | No Violations | |
0215327727 | 2005-05-23 | Production Wells | No Violations | |
0770957535 | 2005-02-15 | Production Wells | No Violations | |
0869150884 | 2011-12-27 | Salt Water Injection Well | No Violations | Tank battery and well are in good repair. The tank battery needs a liner installed if the well is to be put back into use as an injection well. On my last inspection I had a meeting with Gene Moeller. He stated that the well is no longer in use as an injection well. The line from the tank battery to the well is disconnected. Tubing and 4.5 casing are connected to the separator. It is currently cost effective for the operator to have waste water hauled. The lease road is stable and identification sign is posted. |
0955487663 | 2017-06-12 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located along the north perimeter of an industrial facility. At the time of this inspection, I observed the following: a wellhead plunger-lift system with associated tank battery (two 100-barrel steel stock tank and one 50-barrel steel stock tank and separator). The load-line valve was secure and plugged. The tank lid was closed and sealed. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas around the wellhead and battery and found no signs of impact or problems. The access road to the well was grassy but passable. Production reports were current and there was no indication in available electronic records of any deficiencies with bonding or insurance. |
1192004314 | 2009-04-06 | Production Wells | No Violations | no violation |
1295676188 | 2005-02-15 | Production Wells | No Violations | |
1331904320 | 2012-03-15 | UrbanProduction Wells | No Violations | Well is equipped with a con-coil unit. The well and tank battery are in good repair. |
1342206044 | 2012-07-11 | Salt Water Injection Well | No Violations | My inspection today found: no salt water injection taking place. Injection line is disconnected and capped. The tubing and the 4.5 inch annulus are currently being produced. Tubing pressure was 160psi and the annulus pressure was 100psi. Location was in good repair. |
1424277636 | 2015-02-18 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well is located in a level area just north of the main facility, behind a pair of large aboveground storage tanks (ASTs). The well is comprised of a concoil system with associated valve tree and flow line appurtenances. Connections and fittings at the wellhead are secure and free from signs of leakage or problems. The tank battery is another 500 feet to the north and east, along the facility access road. The battery is comprised of 1 210-barrel tank and two 100-barrel steel tanks, and mechanical separator. The battery is shared with the #2-0266 unit. Production reports are current. Emergency contact information is current and functioning. Production appurtenances are painted and red and gray and are in good repair. |
1516970722 | 2012-04-25 | Salt Water Injection Well | No Violations | My inspection toady found, the well and the tank battery in good repair. Injection side of the well is shut off and disconnected. The tank battery dike is sufficient to contain a release. The identification sign is posted on the tank battery. The lease road is stable and constructed out of durable material. |
1874624722 | 2006-11-02 | Production Wells | No Violations | |
1959086456 | 2012-07-11 | Salt Water Injection Well | No Violations | On my inspection of the well site, I was accompanied by DNR Inspector Tom Hill.
The well was equipped to produce not set up for injection. There were no violations at the time. |
2002764169 | 2020-3-23 0:00: | UP | No Violations | |
2121031637 | 2007-10-23 | Production Wells | No Violations | no violation |
215327727 | 2005-5-23 0:00: | PW | No Violations | |
770957535 | 2005-2-15 0:00: | PW | No Violations | |
955487663 | 2017-6-12 0:00: | UP | No Violations | 0.50 |
For data sources see[9]