X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-20914

Well Details

Well ID: 34-085-20914
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Perry Township
Operator Name: RONALD A GIBSON & ASSOC INC
Well Pad ID:
Farm/Lease Name: CARY
License Status: Producing
License Date: 1987-07-31
Spud Date: 1988-01-30
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1988-02-02
Well Total Depth: 3145.00 ft
Configuration: Vertical
Latitude: 41.760000
Longitude: -81.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1987-07-31 198 VIKING RESOURCES CORP GeoDate 7/31/87
Oil and Gas 1987-07-31 Issued Date 7/31/87 Expired Date 7/30/88 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03145 Proposed Drill Depth 03145
Original Spud 1988-01-29
Completed 1988-02-02
Reached Total Depth 1988-02-02
Construction Permit Expires 1988-07-30
Completion Report Received 1991-05-20
Change of Owner 1998-10-06 Operator changed from 198, VIKING RESOURCES CORP to 4908, GIBSON RONALD A & ASSOC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2908 2972 26
2911 2972 0
1997-06-29 2911 2972 0
2908 2972 26
2908 2972 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 54400 Gal 30000 FRAC W/54,400 GAL H20 & 30M# SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 PARTNERS PETROLEUM INC 5803.00 88.00 365
1990 VIKING RESOURCES LLC 18819.00 460.00 365
1992 VIKING RESOURCES LLC 5040.00 42.00 298
1993 VIKING RESOURCES LLC 2885.00 43.00 365
1994 VIKING RESOURCES LLC 3747.00 44.00 365
1995 VIKING RESOURCES LLC 3126.00 0.00 0
1996 VIKING RESOURCES LLC 2526.00 39.00 0
1997 RONALD A GIBSON & ASSOC INC 330.00 0.00 91
1998 RONALD A GIBSON & ASSOC INC 1977.00 0.00 365
1999 RONALD A GIBSON & ASSOC INC 1911.00 28.00 365
2000 RONALD A GIBSON & ASSOC INC 1910.00 23.00 365
2001 RONALD A GIBSON & ASSOC INC 1978.00 20.00 365
2002 RONALD A GIBSON & ASSOC INC 2128.00 20.00 365
2003 RONALD A GIBSON & ASSOC INC 1657.00 23.00 365
2004 RONALD A GIBSON & ASSOC INC 1429.00 0.00 365
2005 RONALD A GIBSON & ASSOC INC 1133.00 24.00 365
2006 RONALD A GIBSON & ASSOC INC 1152.00 0.00 365
2007 RONALD A GIBSON & ASSOC INC 2300.00 5.00 365
2008 RONALD A GIBSON & ASSOC INC 4106.00 41.00 365
2009 RONALD A GIBSON & ASSOC INC 2414.00 14.00 365
2010 RONALD A GIBSON & ASSOC INC 1850.00 22.00 365
2011 RONALD A GIBSON & ASSOC INC 2503.00 0.00 365
2012 RONALD A GIBSON & ASSOC INC 2259.00 43.00 366
2013 RONALD A GIBSON & ASSOC INC 1961.00 42.00 365
2014 RONALD A GIBSON & ASSOC INC 1830.00 28.00 365
2015 RONALD A GIBSON & ASSOC INC 881.00 0.00 365
2016 RONALD A GIBSON & ASSOC INC 496.00 0.00 365
2017 RONALD A GIBSON & ASSOC INC 1555.00 0.00 365
2018 RONALD A GIBSON & ASSOC INC 1101.00 30.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 PARTNERS PETROLEUM INC Brine 1945 365
1990 VIKING RESOURCES LLC Brine 0 365
1992 VIKING RESOURCES LLC Brine 380 298
1993 VIKING RESOURCES LLC Brine 228 365
1994 VIKING RESOURCES LLC Brine 384 365
1995 VIKING RESOURCES LLC Brine 285 0
1996 VIKING RESOURCES LLC Brine 475 0
1997 RONALD A GIBSON & ASSOC INC Brine 25 91
1998 RONALD A GIBSON & ASSOC INC Brine 129 365
1999 RONALD A GIBSON & ASSOC INC Brine 144 365
2000 RONALD A GIBSON & ASSOC INC Brine 186 365
2001 RONALD A GIBSON & ASSOC INC Brine 58 365
2002 RONALD A GIBSON & ASSOC INC Brine 142 365
2003 RONALD A GIBSON & ASSOC INC Brine 138 365
2004 RONALD A GIBSON & ASSOC INC Brine 26 365
2005 RONALD A GIBSON & ASSOC INC Brine 58 365
2006 RONALD A GIBSON & ASSOC INC Brine 40 365
2007 RONALD A GIBSON & ASSOC INC Brine 100 365
2008 RONALD A GIBSON & ASSOC INC Brine 439 365
2009 RONALD A GIBSON & ASSOC INC Brine 439 365
2010 RONALD A GIBSON & ASSOC INC Brine 100 365
2011 RONALD A GIBSON & ASSOC INC Brine 550 365
2012 RONALD A GIBSON & ASSOC INC Brine 340 366
2013 RONALD A GIBSON & ASSOC INC Brine 269 365
2014 RONALD A GIBSON & ASSOC INC Brine 180 365
2015 RONALD A GIBSON & ASSOC INC Brine 40 365
2016 RONALD A GIBSON & ASSOC INC Brine 0 365
2017 RONALD A GIBSON & ASSOC INC Brine 176 365
2018 RONALD A GIBSON & ASSOC INC Brine 62 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1091147198 2010-2-3 0:00:0 PW No Violations
-161547313 2016-11-3 0:00: UP No Violations
-1999851674 2019-6-10 0:00: UP No Violations
-700719478 2017-11-17 0:00 UP No Violations 0.50
000PL14190 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0161547313 2016-11-03 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, the following elements were present: pump jack system and tank battery system in separate, chain-link enclosures. Fittings and connections at the wellhead were secure from leakage or problems. The areas surrounding the wellhead were comprised of an open agricultural field within a larger commercial nursery facility. I walked the area surrounding the wellhead and did not observe any signs of impact or problems. The associated tank battery is located near the main roadway and is shared with the #-2-917 unit. The load-lines were plugged and secure. The tank lids were closed. The secondary containment was dry and free from signs of leakage, spills or other problems. The access road to the battery and well is a shared-use road with the nursery facility and was in good condition. There were no issues or problems requiring attention at the time of this inspection. I noted that there was no apparent production report filed for the 2015 reporting period. I contacted the well owner and he indicated that he would investigate to determine where the missing information was. As of 11/04/2016, the owner had electronically transmitted the Form 10 annual production data for 2015 to ODNR in Columbus.
0326819802 2014-11-10 UrbanProduction Wells No Violations I inspected this location has part of routine inspection activity. The well is producing and production records are current. The fittings and connections at the pump jack are free from signs of leakage or other problems. The chain-link enclosure is intact and locked. Fittings at the tank battery are free from signs of leakage or problems. The load-outs are bull-plugged and locked. Safety equipment is present. Secondary containment is intact. ID Signage is present. The lease road, shared with the nursery facility, is comprised of hard-packed dirt and is dry and stable currently. The battery is shared with the #2-917 unit.
0342480311 2012-02-09 UrbanProduction Wells No Violations Well is a pump jack unit, unit is fenced. Tank battery is fenced. There are two 100 BBL production tanks and a mechical separtor in the battery. Dike is in good repair.
0700719478 2017-11-17 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I found the following: wellhead with pump jack and adjacent tank battery located within the nursery facility, and access roads shared with the nursery. The fittings and connections were secure, Enclosure gates were locked. Load lines were plugged and secure. I walked and inspected the areas surrounding the well and battery and found normal greenscape with no signs of problems or impacts. I had noted during a previous inspection that one of the stock tanks was severely rusted, with several holes. I had advised Ron Gibson that the tank must not be produced into to, and must be removed. He had advised that production into the tank had stopped, and removal of the tank was pending.
0717738538 2013-03-01 UrbanProduction Wells No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead is comprised of a pumpjack unit, not enclosed. The tank battery is comprised of 2 210-barrel (BBL) tanks, mechanical separator, and associated piping and appurtenances, not enclosed. The tank battery system is shared with the #848 producing unit. The ID sign for this unit is in poor condition. I did not observe any leaks, releases, or problems. In contacted Ron Gibson as advised him about the need for a new sign.
1029863516 2018-12-18 UrbanProduction Wells No Violations I conducted an inspection on this well location. The well was equipped with a pumping unit and in production, at the time of this inspection. The well was surrounded by a fence with a locked man door. The diked tank battery was comprised of one 140 BBL tank, one 100 BBL tank and a mechanical separator. The 140 BBL tank has been emptied, cleaned out and disconnected from the other production equipment, but was still inside the diked battery. Signage was located at the well and tank battery. The tank battery was also fenced with a locked man door and shared with well 2-0917. I contacted Ron Gibson of Ronald A. Gibson & Assoc Inc. regarding the removal of the 140 BBL tank.
1091147198 2010-02-03 Production Wells No Violations There were no violations at the time of inspection.
1604986296 2013-10-02 UrbanProduction Wells No Violations The producing unit consists of a pump jack unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 2 100-barrel steel production tanks and a separator unit. The elements are enclosed in separate chain-link enclosures. There is adequate secondary containment and signage at the battery but the wellhead needs a placard. No other problems noted. The battery is shared with the #917 unit.
2027033337 2017-06-08 Production Wells No Violations I inspected this well as part of routine inspection activity. The well with pump-jack system and associated tank battery located within the confines of an active commercial nursery operation. The tank battery is shared with the Cary #1 (#2-0917). The fittings and connecitons at the wellhead and battery were secure. I walked the areas around the well and battery and found so indications or signs of problems. I noted that the signage had become faded and notified Ron Gibson about the need for maintenance. Production reports were current and there were no indications of deficiencies with bonding or insurance in a review of electronic file information conducted on this date.
326819802 2014-11-10 0:00 UP No Violations
342480311 2012-2-9 0:00:0 UP No Violations
717738538 2013-3-1 0:00:0 UP No Violations
PL14190 PL No Violations

For data sources see[9]

References