Well Details

Well ID: 34-085-20550
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Madison Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: BAILEY
License Status: Producing
License Date: 1984-08-16
Spud Date: 1984-11-06
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-11-15
Well Total Depth: 3313.00 ft
Configuration: Vertical
Latitude: 41.740000
Longitude: -81.040000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-02-13 Issued Date 2/13/84 Expired Date 8/11/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1984-08-16 1530 CNG PRODUCING COMPANY GeoDate 8/16/84
Oil and Gas 1984-08-16 Issued Date 8/16/84 Expired Date 2/12/85 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03313 Proposed Drill Depth 03313
Original Spud 1984-11-06 R.I. 8-18-84, CL. QUICKLOOK, R.I. 8-18-84
Completed 1984-11-15 R.I. 8-18-84, CL. QUICKLOOK, R.I. 8-18-84
Reached Total Depth 1984-11-15 R.I. 8-18-84, CL. QUICKLOOK, R.I. 8-18-84
Completion Report Received 1985-01-04 R.I. 8-18-84, CL. QUICKLOOK, R.I. 8-18-84
CO 1985-01-14 1530 CNG PRODUCING COMPANY GeoDate 2/13/84
Construction Permit Expires 1985-02-12 R.I. 8-18-84, CL. QUICKLOOK, R.I. 8-18-84
CO 1991-08-19 28 CGAS EXPLORATION,INC GeoDate 8/16/84
CO 1995-08-17 1966 PETROX INC GeoDate 8/16/84
Change of Owner 2002-01-18 Operator changed from 1966, PETROX INC to 7033, BROAD STREET ENERGY COMPANY
Change of Owner 2015-07-16 Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-02-15 R.I. 8-18-84, CL. QUICKLOOK, R.I. 8-18-84

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3098 3182 0
3098 3182 0
2006-09-11 3099 3144 28
3099 3144 28
3098 3182 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 500 Gal 0
GEL 0 50000 Gal 50000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 CNG PRODUCING COMPANY 31805.00 296.00 365
1986 CNG PRODUCING COMPANY 11095.00 286.00 365
1989 CNG PRODUCING COMPANY 3226.00 81.00 365
1990 CNG PRODUCING COMPANY 2441.00 81.00 365
1991 CGAS EXPLORATION 979.00 0.00 365
1992 CGAS EXPLORATION 2017.00 0.00 366
1993 CGAS EXPLORATION 2003.00 0.00 366
1994 CGAS EXPLORATION 1772.00 89.00 365
1995 CGAS EXPLORATION 1342.00 69.00 365
1996 PETROX, INC 194.00 43.00 365
1997 PETROX, INC 1586.00 41.00 365
1998 PETROX, INC 1012.00 31.00 365
1999 PETROX, INC 1239.00 54.00 365
2000 PETROX, INC 985.00 54.00 365
2001 PETROX, INC 990.00 71.00 365
2002 BROAD STREET ENERGY COMPANY 1169.00 0.00 336
2003 BROAD STREET ENERGY COMPANY 1027.00 48.00 365
2004 BROAD STREET ENERGY COMPANY 944.00 37.00 365
2005 BROAD STREET ENERGY COMPANY 1634.00 0.00 365
2006 BROAD STREET ENERGY COMPANY 1101.00 67.00 365
2007 BROAD STREET ENERGY COMPANY 760.00 0.00 365
2008 BROAD STREET ENERGY COMPANY 696.00 63.00 365
2009 BROAD STREET ENERGY COMPANY 86.00 0.00 365
2011 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2012 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2013 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2014 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2015 M & R INVESTMENTS OHIO LLC 0.00 0.00 0
2016 M & R INVESTMENTS OHIO LLC 10.00 0.00 0
2017 M & R INVESTMENTS OHIO LLC 0.00 0.00 0
2018 M & R INVESTMENTS OHIO LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 CNG PRODUCING COMPANY Brine 915 365
1986 CNG PRODUCING COMPANY Brine 1051 365
1989 CNG PRODUCING COMPANY Brine 340 365
1990 CNG PRODUCING COMPANY Brine 300 365
1991 CGAS EXPLORATION Brine 119 365
1992 CGAS EXPLORATION Brine 60 366
1993 CGAS EXPLORATION Brine 324 366
1994 CGAS EXPLORATION Brine 96 365
1995 CGAS EXPLORATION Brine 140 365
1996 PETROX, INC Brine 148 365
1997 PETROX, INC Brine 126 365
1998 PETROX, INC Brine 205 365
1999 PETROX, INC Brine 213 365
2000 PETROX, INC Brine 140 365
2001 PETROX, INC Brine 69 365
2002 BROAD STREET ENERGY COMPANY Brine 176 336
2003 BROAD STREET ENERGY COMPANY Brine 56 365
2004 BROAD STREET ENERGY COMPANY Brine 0 365
2005 BROAD STREET ENERGY COMPANY Brine 0 365
2006 BROAD STREET ENERGY COMPANY Brine 161 365
2007 BROAD STREET ENERGY COMPANY Brine 131 365
2008 BROAD STREET ENERGY COMPANY Brine 82 365
2009 BROAD STREET ENERGY COMPANY Brine 0 365
2011 BROAD STREET ENERGY COMPANY Brine 0 0
2012 BROAD STREET ENERGY COMPANY Brine 0 0
2013 BROAD STREET ENERGY COMPANY Brine 0 0
2014 BROAD STREET ENERGY COMPANY Brine 0 0
2015 M & R INVESTMENTS OHIO LLC Brine 0 0
2016 M & R INVESTMENTS OHIO LLC Brine 55 0
2017 M & R INVESTMENTS OHIO LLC Brine 0 0
2018 M & R INVESTMENTS OHIO LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1239929044 2018-8-21 0:00: UP No Violations 1.00
-1317851759 2011-5-3 0:00:0 UP No Violations 0.50
-2111842344 2019-10-9 0:00: UP No Violations
000PL14340 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0398100994 2017-04-25 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of the compliance notice, I had noted the following: the production tank was severely corroded with several perforations. In addition, the interior of the tank battery had become overgrown with vegetation, and the unit ID signage had not been updated to reflect the change in ownership. At the time of this inspection, the corroded tank was removed, the signage was updated, and the battery vegetation had been removed. John Raber with M & R Investments has indicated that efforts are on-going to return the well to production.
0642308498 2015-02-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located on the east side of St. Rt. 528. The battery is adjacent to the roadway and the wellhead is located in a farm field and accessed via the same dedicated lease road. At the time of this inspection, the surrounding areas are covered in 8 to 12 inches of snow which obscures some portions of the unit. I observed the valves and connections at the wellhead and the battery to be secure and free from signs of leakage or other problems.
0762596026 2016-09-29 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system and tank battery in separate chain-link enclosures. The well was shut-in and had not had in production since 2009. The tank battery was comprised on one 210-barrel steel production tank, one 140-barrel steel brine tank, horizontal separator, and associated production system appurtenances. The production tank has become severely corroded and has developed several perforating holes, which have compromised the integrity of the tank. In addition, I observed that the interior of the well and battery enclosures was overgrown with vegetation. The ID signage reflects the previous owner, and has not been updated. The owner must do the following by 10/31/2016 or be subject to additional enforcement action: replace the 210-barrel production tank, update the signage to reflect current ownership and contact information, remove the overgrowth of weeds within the individual enclosures. Contact Inspector Stephen Tompkins at 330-907-4647 with any questions about this inspection.
1239929044 2018-08-21 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I noted the following: Fittings and connections at the wellhead and battery were secure and free from signs of leakage. The well was not in active production. I noted that the well ID signage had become faded and unreadable. I also noted that the well interior had become overgrown with vegetation. I advised Bill Fitzmartin with M&R Investments about the need for maintenance. He indicated they would remedy as soon as possible.
1280359685 2010-07-21 Production Wells No Violations No violations were found at the time.
1303755004 2011-04-05 Production Wells No Violations There were no violations at the time of inspection.
1317851759 2011-05-03 UrbanProduction Wells No Violations Tank battery in good repair. Well is not in production. Valve on wellhead is leaking. Contacted Matt Sisson on 5/6/11 to address the issue. Revisited site, valve replaced.
1347033652 2012-09-05 UrbanProduction Wells No Violations I observed a tank battery (TB) consisting of one, 210-barrel (BBL) production tank, one, 100-BBL brine tank, and a mechanical separator unit. The unit is shut-in. There is an identification sign at the TB. The dike appears to be adequate but is overgrown with weeds. The gate is locked. I did not observe any signs of leakage or venting gases. The wellhead is located 100 feet north of the TB. The wellhead consists of a typical valve stem assembly with a plunger lift unit. There are no signs or identification at the wellhead. I did not observe any evidence of gas or oil leakage at the wellhead. The wellhead is enclosed within a 6-foot, chain link style fence. I called Luke about maintenance and he indicated that the well is likely to be plugged.
1347034807 2012-09-05 UrbanProduction Wells Violations Noted I observed a tank battery (TB) conisting of one 110 barrel (BBL) production tank and a mechanical seperator unit. The unit appears to be shut-in. There are no signs or indentification. I did not observe any evidence of gas or oil leakage. The unit appears to be in disrepair. The area within the dike is overgrown with vegetation which has likley compromised the integrity of the containment. I was not able to locate the production wellhead.
1377701864 2013-08-28 UrbanProduction Wells No Violations The interior of the tank battery is overgrown with weeds. The unit ID placard is peeling and not readable.
1395068670 2014-03-17 UrbanProduction Wells No Violations The unit is producing with no indications of leaks or spills. The weed overgrowth has been tended to. The ID placard is still not readable. I notified Ed Butler of the need for a compliant ID and he said he would add it to the maintenance list.
1600443210 2020-9-18 0:00: UP No Violations
398100994 2017-4-25 0:00: UP No Violations 1.00
642308498 2015-2-4 0:00:0 UP No Violations 0.50
677653426 2020-2-3 0:00:0 UP No Violations
762596026 2016-9-29 0:00: UP No Violations 1.00
PL14340 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0762596026 US-OH-128670 2017-10-23 9-05E1 ID (a-i)
0762596026 US-OH-128671 2017-10-23 9-05E5 OPERATIONMAINTANCE (a-c)
0762596026 US-OH-128672 2017-10-23 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
1347034807 US-OH-109852 2012-09-07 Failure to maintain record of pipeline location
1347034807 US-OH-109853 2012-09-07 Inadequate pipeline strength
1347034807 US-OH-109854 2012-09-07 Failure to properly bury pipeline

For data sources see[9]