34-073-23145

Well Details

Well ID: 34-073-23145
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: JANE INV INC
License Status: Producing
License Date: 1995-11-14
Spud Date: 1985-12-10
Spud Drilling Contractor: CARR DRILLING
Final Drill Date: 1986-01-23
Well Total Depth: 2697.00 ft
Configuration: Vertical
Latitude: 39.520000
Longitude: -82.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1985-12-03 Issued Date 12/3/85 Expired Date 12/3/86 Acres 0021390 Tool Type CT Proposed Formation CLINTON Proposed Depth 02697 Proposed Drill Depth 02697
Original Spud 1985-12-10
Completed 1986-01-23
Reached Total Depth 1986-01-23
CO 1986-02-03 723 DEVOL DANNIE GeoDate 12/3/85
Completion Report Received 1986-02-11
Construction Permit Expires 1986-12-03
Annular Disposal Well 1995-11-14
Revocation 2011-03-01
Change of Owner 2013-02-13 Operator changed from 723, DEVOL DANNIE to 5755, CHIEFTAIN ENERGY CORP
Last Compliance Report 2016-11-10
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0 NONE;NATURAL

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 DEVOL DANNIE 470.00 298.00 155
1995 DEVOL DANNIE 481.00 348.00 178
2007 DEVOL DANNIE 125.00 141.00 52
2009 DEVOL DANNIE 100.00 139.00 15
2014 HOCKING HILLS ENERGY AND WELL 0.00 26.00 365
2016 HOCKING HILLS ENERGY AND WELL 0.00 38.00 365
2017 HOCKING HILLS ENERGY AND WELL 57.00 114.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 DEVOL DANNIE Brine 0 155
1995 DEVOL DANNIE Brine 0 178
2007 DEVOL DANNIE Brine 246 52
2009 DEVOL DANNIE Brine 202 15
2014 HOCKING HILLS ENERGY AND WELL Brine 0 365
2016 HOCKING HILLS ENERGY AND WELL Brine 0 365
2017 HOCKING HILLS ENERGY AND WELL Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-374514160 2017-12-12 0:00 PW No Violations
-821100623 2008-12-30 0:00 PW No Violations
-87381420 2017-1-17 0:00: PW No Violations 0.30
-966413378 2011-3-17 0:00: AD No Violations 3.00
000PL16081 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
001269i141 2000-11-21 Annular Disposal No Violations AD test on this well , took several times pre-testing and re-testing before well would test. After loosing around 2lb in 15 min the well finally passed the test.
0087381420 2017-01-17 Production Wells No Violations Production well inspection. The well consists of a pumping unit, 2-100 barrel tanks, 1-20 barrel tank, separator and gas meter. Legible identification posted.
0169408962 2006-08-16 Annular Disposal No Violations No violations were noted.
0374514160 2017-12-12 Production Wells No Violations Inspection with Eric Conrad, findings match Inspectors prior report.
0821100623 2008-12-30 Production Wells No Violations Met with Mr. Dannie Devol at the well site to explain well ownership classification. Mr. Devol was informed that he does not meet the criteria for an exempt domestic well owner. Mr. Devol was also provided with ownership information to aid with resolving this deficiency.
0915498257 2007-09-10 Production Wells No Violations No violations were noted.
0966413378 2011-03-17 Annular Disposal No Violations Witnessed annular disposal test conducted by Rocky King. No violations at well or tank battery. However, brine tank has holes in it as big as 1 foot in diameter. The holes are close to the middle of the tank, and do not affect the bottom 2.5 feet of the tank. Tank was not leaking, and showed no evidence of leaking in the past. A recommendation was made to Doug Rice that the tank should either be repaired or replaced. There was also a union that connected the knockout tank to the oil tank that showed evidence of past leakage. I recommended either tightening or replacing that as well.
1140738860 2006-02-21 Annular Disposal No Violations AD test on well, well passed test.
1226578397 2008-11-05 Production Wells No Violations An inspection was requested by Columbus to verify exempt domestic well status. During the inspection, it was found that this well does not meet the criteria to be considered as an exempt domestic well. The well was observed to be tied into a meter. The pumper for Mr. Dannie Devol also confirmed that gas is being sold from this well.
1269i141 2000-11-21 0:00 AD No Violations
1300370004 2011-03-17 Annular Disposal No Violations Annulas test ( MIT ) test pressure at 190 psi. test passed this date.
1346467589 2004-09-08 Annular Disposal No Violations No violations. NEW LAT & LONG
1474465580 2016-09-21 Temporary Abandoned Annular Disposal No Violations Temporary abandon annular disposal inspection. The well is not hooked up and is not being used for annular disposal.
169408962 2006-8-16 0:00: AD No Violations
915498257 2007-9-10 0:00: PW No Violations
PL16081 PL No Violations

For data sources see[8]