X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-22900

Well Details

Well ID: 34-073-22900
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Washington Township
Operator Name: POLING ALBERT
Well Pad ID:
Farm/Lease Name: POLING-HERRON
License Status: Producing
License Date: 1983-11-03
Spud Date: 1984-01-10
Spud Drilling Contractor: GRIM DRILLING
Final Drill Date:
Well Total Depth: 0.00 ft
Configuration: Vertical
Latitude: 39.470000
Longitude: -82.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-11-03 283 POLING ALBERT GeoDate 11/3/83
Oil and Gas 1983-11-03 Issued Date 11/3/83 Expired Date 5/1/84 Acres 0054510 Tool Type RTF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1984-01-10 PERMIT EXPIRED.
Construction Permit Expires 1984-05-01 PERMIT EXPIRED.
Last Compliance Report 2014-08-05 PERMIT EXPIRED.
Record Last Modified 2014-08-05 PERMIT EXPIRED.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 POLING ALBERT 0.00 0.00 180
2012 POLING ALBERT 0.00 0.00 366
2013 POLING ALBERT 0.00 0.00 140
2014 POLING ALBERT 0.00 0.00 365
2016 POLING ALBERT 0.00 0.00 365
2017 POLING ALBERT 0.00 0.00 180

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 POLING ALBERT Brine 0 180
2012 POLING ALBERT Brine 0 366
2013 POLING ALBERT Brine 0 140
2014 POLING ALBERT Brine 0 365
2016 POLING ALBERT Brine 0 365
2017 POLING ALBERT Brine 0 180

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1084229222 2013-1-9 0:00:0 PW No Violations 1.00
-1334394386 2013-1-9 0:00:0 PW No Violations 1.00
-1536332187 2013-3-27 0:00: PW No Violations 1.00
-1553058922 2014-7-17 0:00: PW No Violations 2.00
-1695003159 2013-3-27 0:00: PW No Violations 0.50
-333876305 2009-12-28 0:00 AD No Violations
0333876305 2009-12-28 Annular Disposal No Violations An inspection of this well was requested by Central Office to verify Annular Disposal (AD) connection. During the inspection, it was noted that the AD remains disconnected. Note: snow cover at time of inspection.
0848833317 2019-04-18 Production Wells No Violations My inspection revealed that the well consists of 2.38 inch tubing inside of 4.5 inch casing. I observed a plastic flow line connected to the tubing. The tubing was equipped with a 2 inch ball valve that was shut in. I contacted Albert Poling at 3:50 PM regarding this inspection. Mr. Poling told me he utilizes gas from this well for one of the buildings on the property. Time of inspection: 8:35 AM.
1084229222 2013-01-09 Production Wells Violations Noted There is no pumping unit on this well. There is swage and a reducer with 1 inch black plastic pipe connected to it. The 1 inch black plastic is broke off. There is no identification posted on the well. I spoke with Mr. Albert Poling on the phone on 1/9/13 at 9:28 am he stated this well was used primarily to heat his building. I suggested to him that he should put a meter on the line to report production. Production has never been reported on this well. I told him that identification needs to be posted on the well. I also gave him the number for Patty Nicklaus at the Columbus office so that he can acquire the proper forms. Production needs to be reported for this well.
1107292325 2005-02-01 Annular Disposal No Violations No violations, Checked AD for Columbus, AD not used. NEW LAT & LONG
1334394386 2013-01-09 Production Wells No Violations FOLLOW UP TO NOV # -1084229222 There is no pumping unit on this well. There is swage and a reducer with 1 inch black plastic pipe connected to it. The 1 inch black plastic is broke off. There is no identification posted on the well. I spoke with Mr. Albert Poling on the phone on 1/9/13 at 9:28 am he stated this well was used primarily to heat his building. I suggested to him that he should put a meter on the line to report production. Production has never been reported on this well. I told him that identification needs to be posted on the well. I also gave him the number for Patty Nicklaus at the Columbus office so that he can acquire the proper forms. Production needs to be reported for this well.
1536332187 2013-03-27 Production Wells No Violations Hocking county training with Andy Thomas, this well does not have a tank. It is a gas well only.
1553058922 2014-07-17 Production Wells No Violations Compliance notice follow-up. The well has production reported and has a legible identification. This satisfies the compliance notice.
1695003159 2013-03-27 Production Wells No Violations No attempt has been made by company to gain compliance. Spoke with Mr. Albert Poling, and his daughters boyfriend Jason. Inspector Kip Thompson and I reviewed with him the list of needed remedial actions and gave him the phone numbers for the people in Columbus he needs to talk to in order to acquire the needed forms.
848833317 2019-4-18 0:00: PW No Violations 0.20

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1084229222 US-OH-101909 2013-01-11 Failure to legibly identify well
1084229222 US-OH-101910 2013-01-11 Statement of annual production not filed

For data sources see[7]