Well ID: 34-073-22211
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: LOGAN SAND & GRAVEL CO
License Status: Active Injection
License Date: 2006-05-08
Spud Date: 1979-12-06
Spud Drilling Contractor:
Final Drill Date: 1979-12-11
Well Total Depth: 3114.00 ft
Configuration: Vertical
Latitude: 39.480000
Longitude: -82.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-10-22 2810 CHIEFTAIN ENERGY CORP GeoDate 10/22/79
Oil and Gas 1979-10-22 Issued Date 10/22/79 Expired Date Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1979-12-06
Completed 1979-12-11
Reached Total Depth 1979-12-11
Completion Report Received 1980-03-11
CO 1994-07-07 4074 OIL ENTERPRISES GeoDate 10/22/79
CO 1997-02-18 5755 CHIEFTAIN ENERGY CORP. GeoDate 10/22/79
APP 2006-05-08 Proposed Formations:CLINTON, Issued Date:5/8/2006, Expired Date:5/8/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:EOR, Proposed Well Class:ERP
Annulus Pressure Monitoring Approved 2006-10-26
Last Compliance Report 2006-10-30
Construction Permit Expires 2007-05-08
Record Last Modified 2014-09-25

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-05-08 2933 2950 11
2933 2950 11
2933 2950 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 61250 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 MUTUAL OIL & GAS CO 5599.00 235.00 0
1985 MUTUAL OIL & GAS CO 4191.00 125.00 0
1986 MUTUAL OIL & GAS CO 1800.00 83.00 365
1987 MUTUAL OIL & GAS CO 9.00 0.00 0
1988 HOCKING HILLS ENERGY AND WELL 3253.00 44.00 260
1989 HOCKING HILLS ENERGY AND WELL 3280.00 42.00 300
1990 HOCKING HILLS ENERGY AND WELL 2686.00 23.00 300
1991 HOCKING HILLS ENERGY AND WELL 953.00 54.00 300
1992 HOCKING HILLS ENERGY AND WELL 1176.00 102.00 251
1995 OIL ENTERPRISES 1375.00 140.00 365
1996 OIL ENTERPRISES 1206.00 51.00 365
1997 HOCKING HILLS ENERGY AND WELL 1361.00 0.00 365
1998 HOCKING HILLS ENERGY AND WELL 1361.00 0.00 365
1999 HOCKING HILLS ENERGY AND WELL 1321.00 0.00 140
2000 HOCKING HILLS ENERGY AND WELL 1202.00 0.00 140
2001 HOCKING HILLS ENERGY AND WELL 1415.00 50.00 365
2002 HOCKING HILLS ENERGY AND WELL 1375.00 56.00 365
2003 HOCKING HILLS ENERGY AND WELL 1100.00 43.00 365
2004 HOCKING HILLS ENERGY AND WELL 981.00 36.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 MUTUAL OIL & GAS CO Brine 0 0
1985 MUTUAL OIL & GAS CO Brine 0 0
1986 MUTUAL OIL & GAS CO Brine 0 365
1987 MUTUAL OIL & GAS CO Brine 0 0
1988 HOCKING HILLS ENERGY AND WELL Brine 276 260
1989 HOCKING HILLS ENERGY AND WELL Brine 324 300
1990 HOCKING HILLS ENERGY AND WELL Brine 312 300
1991 HOCKING HILLS ENERGY AND WELL Brine 265 300
1992 HOCKING HILLS ENERGY AND WELL Brine 311 251
1995 OIL ENTERPRISES Brine 270 365
1996 OIL ENTERPRISES Brine 300 365
1997 HOCKING HILLS ENERGY AND WELL Brine 190 365
1998 HOCKING HILLS ENERGY AND WELL Brine 120 365
1999 HOCKING HILLS ENERGY AND WELL Brine 160 140
2000 HOCKING HILLS ENERGY AND WELL Brine 200 140
2001 HOCKING HILLS ENERGY AND WELL Brine 540 365
2002 HOCKING HILLS ENERGY AND WELL Brine 320 365
2003 HOCKING HILLS ENERGY AND WELL Brine 160 365
2004 HOCKING HILLS ENERGY AND WELL Brine 205 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1006309625 2009-9-4 0:00:0 ER No Violations
-1019877444 2012-9-14 0:00: SC No Violations 2.50
-102072007 2015-9-23 0:00: ER No Violations 3.00
-1116586588 2009-6-2 0:00:0 ER No Violations
-1123703794 2019-1-28 0:00: SW No Violations 0.30
-1167754030 2012-2-23 0:00: SC No Violations
-1230306936 2010-6-15 0:00: ER No Violations
-1250352730 2012-7-6 0:00:0 SC No Violations
-128373724 2017-5-25 0:00: SW No Violations
-1353175915 2012-2-8 0:00:0 ER No Violations 1.50
-1381541048 2009-6-2 0:00:0 ER No Violations
-1432912921 2014-3-20 0:00: SW No Violations 1.00
-1483595985 2015-6-22 0:00: ER No Violations 2.50
-1485677477 2004-9-28 0:00: AD No Violations
-1507049274 2020-7-9 0:00:0 ER No Violations 1.00
-1592764413 2012-2-23 0:00: ER No Violations 3.50
-1609198785 2009-7-20 0:00: ER No Violations
-1625747241 2009-6-2 0:00:0 ER No Violations
-1676404973 2013-7-3 0:00:0 SW No Violations 2.00
-1724006903 2006-3-29 0:00: AD No Violations
-1766418051 2009-1-21 0:00: SC No Violations
-1767643327 2012-8-20 0:00: ER No Violations 2.00
-1812844999 2012-6-20 0:00: SC No Violations 3.00
-1834966995 2011-12-15 0:00 ER No Violations 1.50
-1874240395 2011-3-31 0:00: ER No Violations
-1923010994 2013-4-10 0:00: ER No Violations 3.50
-1944722098 2012-8-7 0:00:0 SC No Violations 1.00
-1984598286 2012-7-6 0:00:0 SC No Violations 4.00
-198736282 2007-9-5 0:00:0 SC No Violations
-2026205392 2007-6-26 0:00: SC No Violations
-2097609832 2016-3-17 0:00: ER No Violations
-210087111 2015-9-8 0:00:0 ER No Violations 8.00
-2146088841 2015-9-14 0:00: ER No Violations 1.50
-245808127 2010-5-24 0:00: ER No Violations
-251294628 2015-9-25 0:00: SW No Violations 5.00
-334399596 2017-10-4 0:00: SW No Violations 1.50
-356568051 2012-8-23 0:00: ER No Violations 2.00
-371501340 2013-1-10 0:00: ER No Violations 4.50
-397182149 2010-1-4 0:00:0 ER No Violations
-545950718 2008-1-4 0:00:0 SC No Violations
-550750583 2020-4-2 0:00:0 ER No Violations 3.00
-563611421 2009-6-2 0:00:0 ER No Violations
-581161508 2013-1-10 0:00: ER No Violations 4.00
-595775573 2014-10-1 0:00: ER No Violations 5.00
-614847614 2015-3-24 0:00: SW No Violations 1.00
-646446501 2004-5-13 0:00: AD No Violations
-650820019 2010-5-10 0:00: ER No Violations
-653344562 2012-7-16 0:00: SC No Violations 2.00
-747208354 2018-8-14 0:00: ER No Violations 0.50
-833622331 2016-8-31 0:00: ER No Violations 3.00
-852311835 2018-5-15 0:00: ER No Violations 0.60
-897233267 2008-7-10 0:00: ER No Violations
-897437627 2011-7-6 0:00:0 ER No Violations
-906073541 2009-6-2 0:00:0 ER No Violations
-91643873 2008-11-26 0:00 SC No Violations
-916443054 2008-7-17 0:00: ER No Violations
-923987207 2012-2-9 0:00:0 ER No Violations 4.50
0031053836 2007-07-30 Surface Facility Construction No Violations An inspection was conducted on 7/30/2007 with Mr. Doug Kitchen and Mr. Ron McBride. During the inspection, it was noted that the dike height along the far end of the constructed dike has not been addressed. This issue was brought to Mr. Kitchens attention. It was also noted that the 30mm liner has not been installed. Mr. Kitchen also states that they would like to build the unloading pad in a different location and utilize different size tanks. He was instructed to reflect these changes on his design and submit this information to Mr. Tom Tomastik. Mr. Kitchen was again informed that this site would require fence placed around the facility, and a plastic tank (vault) will not be allowed. He was instructed to use a concrete vault that is coated. More work will be needed to complete the construction of this facility.
0040479472 2010-03-12 Enhanced Recovery Project No Violations A follow-up inspection to NOV and Compliance Agreement Schedule revealed that the previously noted violations have now been resolved. During the inspection, it was noted that oil exists inside the earthen dike at the storage tank location. Old and fresh oil on surface of water throughout dike. Old pads were observed on one end of the dike and will need replaced. The source of release is from the overflow of storage tank. Oil stains were observed from top of tank to ground surface, in dike, on two separate ends. A plug will be recommended for open PVC drain at the unloading pad to prevent overflow of concrete vault. Note: PVC routed from drain to concrete vault. Remedial Restoration will be recommended for the Spring, due to erosion at well location and along lease road. At 10:48 am, the well owner, Doug Kitchen, was notified on location, by telephone of inspect results and deficiency with non-related well. Mr. Kitchen states Ron McBride will cleanup P&C this weekend; agreed that Remedial Restoration work needed and will apply seed. He was instructed to perform work when the weather drys, but before June. Mr. Kitchen agreed that a plug for PVC drain is a good idea.
0057766270 2011-02-01 Enhanced Recovery Project No Violations An inspection conducted with Mr. Andy Thomas revealed no violations at this time. Note: snow cover at time of inspection.
0062416454 2008-11-25 Surface Facility Construction No Violations An inspection revealed that Chieftain Energy is preparing to install a concrete vault for the unloading pad location. Chieftain Energy will be coating both the inside and outside of this vault with tar.
0071971176 2016-03-21 Enhanced Recovery Project No Violations Chief Order # 2015-445 Follow up inspection. Well is disconnected from injection equipment. Containment dike has 8 of water in it. Standing water between the well and the containment dike was tested using High Range Quantabs. Results ranged from 3700 ppm cl to 486 ppm Cl.
0091643873 2008-11-26 Surface Facility Construction No Violations An inspection was conducted to ensure that the concrete vault was properly coated with tar. Witnessed Chieftain Energy employees coat the inside walls of the vault. The bottom (inside) of this vault contained ice therefore, not allowing the application of material. The company therefore, removed the ice and will allow the bottom to dry.
0102072007 2015-09-23 Enhanced Recovery Project No Violations Chief Order # 2015-445 follow up inspection. Both containment dikes have fluid in them. No equipment is on site to remove contaminated material. An additional scald area was observed along the access road at GPS N39.48989 / W082.39777. The scald area is roughly a triangle shape that flows into the wood line. Dimensions are 34 by 26 by 44. This area is stained dark and is completely devoid of vegetation. A field test of the soil revealed 2930 ppm Cl.
0128373724 2017-05-25 Salt Water Injection Well No Violations Salt water injection well inspection. The well had 0 psi on the injection tubing and 0 psi on the annulus. The well is currently not in use.
0134367124 2018-01-18 Salt Water Injection Well No Violations The salt water injection well had 74 psi on the annulus. The injection tubing is disconnected from the primary injection line. The well is not being used for injecting salt water. The well owner has plans to rebuild the facility before the well is used again.
0146196985 2011-12-15 Enhanced Recovery Project No Violations Accompanied by Andy Thomas MRI. The 1/4 needle valve on the injection tubing needs to be replaced. Dike is full of water. A new mail box has been installed at the unloading pad. It has a brine load slip book inside. A large white tank is on location it is not being used at this time. Andy has contacted the company regarding the water in the dike and the needle valve.
0156012850 2010-06-10 Enhanced Recovery Project No Violations Witnessed Injection Line Test on 2 steel line. The line did not pass the reqiured test, due to leakage from two points above ground near test gauge location on end. Test Data: 780 psi at 1:29 p.m. to 705 psi at 1:32 p.m. (leak @ split connection near gauge). Attempt to tighten and re-test. Re-pressured to 730 psi @ 1:36 p.m. and pressure still continued to drop. Second leak near end of line after check valve. Will re-test next week. The check will be removed for next test.
0198736282 2007-09-05 Surface Facility Construction No Violations Checked on the surface facility construction. No activity was observed.
0210087111 2015-09-08 Enhanced Recovery Project No Violations Compliance notice follow-up. Accompanied by Jake Glasscock DOGRM Geologist and Josh Garland MRI 2. Both containment dikes have water and oil in them. Capacity in containment dikes is reduced to at least half of the required amount. The 300 barrel tank and the 210 barrel tank show signs of over flowing on the sides. The roll off box has been removed from the location. Oil residue and a narrow scald area was observed where the roll off box was located. The contaminated area outside of the containment dikes was delineated and 4 soil samples were collected (3 from the contaminated area and 1 control sample). Soil samples were taken to the ODNR Lab.
0224425600 2009-12-03 Enhanced Recovery Project No Violations A follow-up inspection revealed non-compliance. During the inspection, it was noted there is no pressure on annulus, and oil and brine inside dike. Absorbent pads were also observed inside the dike. The concrete vault was full of fluid and appears to have overflowed, as Cl- was observed in standing water around the area. The unloading pad contains open hole for drainage to vault (PVC pipe). The installation of a cap to prevent overflow from rainfall events will be recommended to company.
0245808127 2010-05-24 Enhanced Recovery Project No Violations A follow-up inspection revealed non-compliance.
0251294628 2015-09-25 Salt Water Injection Well No Violations Hocking Hills Energy has finished the demolition of the pump house. The concrete has been loaded in a container and taken to Kilbargers landfill. The contaminated soil has been separated and loaded into containers and taken to the landfill. I monitored the removal of soil that contained chlorides. This soil was also loaded in containers and taken to landfill.
0261149307 2012-07-13 Surface Facility Construction No Violations There was no activity at the site. Doug Kitchen was on site. I spoke with him about what his plans were as far as finishing the tank battery liner.
0278715626 2010-09-07 Brine Hauler Violations Noted On 9/4/2010, a complaint was received by the DMRM alleging that Mr. Doug Kitchen, President of Chieftain Energy Corp, had dumped pit water onto this lease road on 9/3/2010. The complainant observed normal lease road condition the morning of the 3rd, but later that evening would see a noticeable change. The complainant states that Mr. Kitchen had been hauling fluid from drilling location of Permit No. 3595. An inspection revealed that the entire lease road measuring approx 1000 x 10 contained brine and pockets of oil. The road surface was silted/smooth resembling a ground surface after applicaion of fluid. A change in the road condition began at entrance, into ERP, just past the gate. A puddle measuring approx 5 in width reached maximum units on Low Range Quantabs. At the ERP location, fresh oil was observed throughout the inside of earthen dike. The source is from 200 bbl horizontal tank, which has overflowed. The tank was wet at top on both ends. At Permit No. 3595 location, spoke with Mr. Jim Kilbarger, Logan Gas (partnership), and Dave Barry with Petroleum Development Corp., regarding fluid hauled from Permit No. 3595. Both individuals confirmed Chieftain Energy hauled fluid from this location. Mr. Kilbarger states approx 6 loads were hauled from the blow pit. He further stated that Mr. Kitchens water truck broke down on Sunday, 9/5/10. Left message for Mr. Kitchen on cell phone at 11:45 stating to return call as soon as possible. Mr. Kitchen returned call at 3:29 p.m. and stated so whats this I hear about a problem with me putting water on my lease road for dust control? Mr. Kitchen was then advised that this activity is not allowed per SB 165. Furthermore, he does not even have a Brine Resolution Plan with the UIC section. Mr. Kitchen was given the telephone number for Mr. Robert Stonerock, South Region Oil & Gas Supervisor. Mr. Kitchen stated that tomorrow he would bring a dozer out and backblade the road. Mr. Kitchen was instructed not to
0298240305 2010-09-22 Enhanced Recovery Project No Violations A follow-up inspection revealed that absorbent pads have now been applied to locations inside the dike. Oily soil and sheen on surface of fluid still remain from tank overflow.
0331422685 2016-02-03 Enhanced Recovery Project No Violations Chief Order No. 2015-445 Follow up inspection. Injection tubing master valve is closed. Injection tubing is not connected to injection line or equipment. The containment dike has 16 of water in it. The Annulus has 5 psi.
0334399596 2017-10-04 Salt Water Injection Well No Violations The brine contamination has been cleaned up. Thick vegetative cover has been established. The well is currently not in use. There is a small amount of fluid in the containment dike. The well is on vacuum and has 0 psi on the annulus. I have contacted Hocking Hills Energy to remove the fluid from the dike.
0356568051 2012-08-23 Enhanced Recovery Project No Violations Witnessed mechanical integrity test on the annulus. Test was performed twice. 4.5 well head was leaking pressure off. Well did not pass. Rubber seals in the well head will be replaced.
0359615844 2015-12-31 Enhanced Recovery Project No Violations Chiefs Order # 2015-445 Follow up inspection. The containment dike has over 18 of water in it. The injection tubing is not connected to injection equipment. The master valve is closed. Checked the annulus pressure which was at zero pressure with fluid observed at the surface when the gauge was removed. There has been no effort to complete the remediation of the contaminated soil.
0371501340 2013-01-10 Enhanced Recovery Project No Violations Checked injection and annulus pressures. There was fluid in both containment dikes. Where the liner had been added to on one of the containment dikes the adhesive tape was not holding. The vault the held fluid from the unloading pad had over flown. One of the tanks had also over flown and oily material was left in the dike. Mr. Bill Deible was called and he came out to the site. These issues and their remedies were discussed. We also discussed their sump system and the way it was plumbed. Inspector Jon Scott was also on site. He will be issuing the Compliance Notice. Flowmeter displays information in gallons.
0375637493 2008-08-08 Enhanced Recovery Project No Violations An inspection revealed that the surface facility has not been constructed. A new pump was observed to have been installed. No activity observed at time of the inspection.
0378216293 2008-12-08 Surface Facility Construction No Violations An inspection revealed no activity. During the inspection, it was noted that the bottom (inside) of concrete vault contains tar.
0388118204 2012-02-22 Enhanced Recovery Project No Violations Measured the new dike that was being constructed with Inspectors Jon Scott and Kip Thompson. Also witnessed sand being placed in the bottom of it. In the existing dike, there was an excess of fluid which needed pumped out. The sump pit was also full. A phone call was made to Mr. Doug Kitchen of Chieftain Energy and corrective action was taken immediately.
0390510777 2016-06-15 Enhanced Recovery Project No Violations Chiefs Order # 2015-445 follow up inspection. The visible holes in the pit liner have been repaired. The pit level is at approximately 6. The scald area has been graded. No vegetative cover established. The Inspector was not notified of the pit liner repairs or the site work on the scald area. This activity was not witnessed. The injection tubing is not connected to any injection equipment.
0395669655 2006-06-19 Enhanced Recovery Project No Violations No violations.
0397182149 2010-01-04 Enhanced Recovery Project No Violations A follow-up inspection revealed non-compliance. During the inspection, it was noted that no pressure exists on the injection and annular side of the well. The area inside the dike containing a liner found to contain P&C, as previously noted still exist. The concrete vault that had overflowed is still full but is now frozen. Chieftain Energy has been sent a NOV and also verbally instructed on several occassions in regards to positive pressure on annulus. Furthermore, if no pressure is placed on annulus, notify me to witness monthly mini-test. Note: snow cover at time of inspection.
0475214848 2018-08-07 Enhanced Recovery Project No Violations Chief Order # 2015-445 follow up inspection. The injection well is not connected to injection equipment or injection line. The containment dike is full of fluid. Identification is posted at the well. Vegetative cover is established on the remediated areas.
0545950718 2008-01-04 Surface Facility Construction No Violations An inspection revealed that the surface facility is not finished. Mr. Doug Kitchen was informed that if changes are made to the original design, he would need to send Tom Tomastik a revised drawing of this facility. No pressure observed on the annulus and injection side of the well.
0563611421 2009-06-02 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed on the injection side of the well. The iden
0581161508 2013-01-10 Enhanced Recovery Project Violations Noted Inspected enhanced recovery well injection tubing pressure and annulus pressure. Good identification at well head. Facility has two dikes. Both dikes have fluids in them. The dike with the brine pump has oil in the dike. Remove all fluids from the dike and clean up all contaminated areas with in the dike. Unloading pad vault has over flowed oil and fluids onto the ground (contaminated area 4 feet in diameter). Previous repairs to the dike liner are not effective. The repair material has separated from the dike liner. Dike liner must be water tight. Repair or replace dike liner. Accompanied by Andy Thomas MRI 2.
0595775573 2014-10-01 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # 1412190582 Inspected the unloading pad, containment dikes, tanks, injection line, annulus pressure and injection pressure. A scald area was observed outside the containment dikes. Approximately 75 by 3. Soil was field tested for chlorides. High range Quantab was maxed out at 6508 ppm Cl. I called Bill Diebel and he came out to the well site. I told Bill that the contaminated area must be remediated. The unloading pad sump had overflowed as well. I told Bill that the sump needs to be upgraded to prevent surface water from flowing into the top of the sump pit. I called Dave Poling and discussed the sump pit issues and what was needed to remediate the contaminated areas. I told Dave that the sump must be one piece construction with the top extending at least 6 above the ground level.
0596856320 2014-08-04 Salt Water Injection Well No Violations UIC inspection. The well has 142 PSI on the annulus, and the injection side is on vacuum. No violations noted.
0614847614 2015-03-24 Salt Water Injection Well No Violations UIC inspection. The injection side is on vacuum, the annulus pressure was 73 PSI. The dikes have water in them, I have contacted Hocking Hills Energy to have the dikes pumped out.
0640176974 2008-06-16 Enhanced Recovery Project Violations Noted A complaint was received by the DMRM alleging that Chieftain Energy had released excess oil and brine from water truck onto the lease road and around the well site. The complainant also stated that Chieftain Energy has been unloading fluid from their water truck directly into the well. Further stating that this activity has been occurring for quite some time. The surface facility has not been completed. An inspection revealed puddles of brine on the lease road. and bare areas around the well site. Oil was also observed, on the ground, located along the edge of wooded area. Mr. Doug Kitchen was verbally instructed to complete surface facility before injecting any fluid and that unloading from water truck is not allowed. Mr. Kitchen will be required to perform cleanup and remove contaiminated soil.
0646446501 2004-05-13 Annular Disposal Violations Noted An inspection of the well revealed no ID at the well, oily soil around the well and tank battery, bare areas on well site.
0650820019 2010-05-10 Enhanced Recovery Project No Violations A follow-up inspection revealed non-compliance. Arrived at the location and observed Chieftain Energy Contractor, Mr. Ron McBride leaving the location. Mr. McBride states dont bother going back to location because its not cleaned up. Mr. McBride agreed to perform cleanup by 5/14/2010. Mr. McBride was informed that the injection line would need to be tested and remedial restoration are required. Furthermore, a gas line from non-related well routed through this location contains a leak. An inspection of the well site revealed non-compliance.
0653344562 2012-07-16 Surface Facility Construction No Violations Witnessed the patching of the liner. Approved materials were used. Accompanied by Steve Riley.
0682000589 2009-06-02 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed on the injection side of the well. The identification at the well missing ERP # and need ID at tank.
0714685875 2013-02-06 Enhanced Recovery Project No Violations Dike contamination has been cleaned up and hauled to landfill.
0716073848 2015-09-08 Enhanced Recovery Project No Violations Accompanied Jon Scott and Jake Glascock on a site facility assessment. A large volume of brine had escaped from the containment facility and contaminated the ground. Soil samples taken, field sample tests ran for Chlorides, pictures taken, site measured.
0739028801 2016-06-02 Salt Water Injection Well No Violations I received a call from Hocking Hills Energy. They stated they would be working on repairing the dike liner that as damaged by a tree. The dike has 9 holes that was caused by the tree falling. The manufacture of the liner sent the repair material. The area around the holes was cleaned of all contaminates before the patch was applied using rubbing alcohol. Hocking Hills Energy began removing soil that is contaminated with brine. This area is located at the east side of the existing dike. Quantabs showed reading of approx. 800 PPM.
0747208354 2018-08-14 Enhanced Recovery Project No Violations Chiefs Order 2015-445 follow up with ODNR DOGRM UIC section Geologist. The containment dike is full of fluid. The dike fluid has a sheen. The injection tubing is not connected to injection equipment.
0755009655 2004-11-26 Annular Disposal No Violations Follow-up on NOV, In-Compliance.
0833622331 2016-08-31 Enhanced Recovery Project No Violations Chief Order # 2015-445 follow up inspection. The containment dike is full of fluid. The injection tubing is not connected to an injection line or equipment. Vegetative cover has been established on the reclamation site. The injection tubing master valve is closed. The annulus has zero pressure.
0852311835 2018-05-15 Enhanced Recovery Project No Violations Chief Order # 2015-445 Follow up Inspection. The containment dike has 18 inches of fluid in it. The fluid has an oil sheen. The well is not connected to an injection line or injection pump. The injection tubing master valve is closed. Identification is posted at the well. Vegetative cover has been established on the location.
0897233267 2008-07-10 Enhanced Recovery Project No Violations A follow-up inspection now revealed 43 ( outside width) x 90 (length) kill area consisting of dead trees and grass. The width of the kill area decreases from 43 to 20 inside the tree line.
0897437627 2011-07-06 Enhanced Recovery Project Violations Noted Zero pressure on injection tubing. Zero pressure on annulus. Test Annulus to 675 psi for 15 minutes. Schedule test with Jon Scott MRI2 740-624-4963. Brine on wellhead maxed out High End Quantabs. Repair or replace tubing at wellhead. Brine in dike. Remove brine from dike and dispose in an Injection well. Replace 1/4 needle valve on Injection tubing.
0906073541 2009-06-02 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed on the injection side of the well. The identification at the well does not contain the ERP #. No identification was observed at the storage tank. The contractor for Chieftain Energy., Mr. Ron McBride, was notified of the deficiencies, in person, on 6/2/2009 at approximately 12:30 pm.
0916443054 2008-07-17 Enhanced Recovery Project No Violations Checked on status of cleanup. Cleanup has been performed. Seed, straw, lime and new topsoil observed. Run tickets have not been received.
0923987207 2012-02-09 Enhanced Recovery Project No Violations Accompanied by Inspector Kip Thompson, I witnessed the construction of a new tank battery containment for added storage for this facility.
0930934140 2014-04-09 Enhanced Recovery Project Violations Noted Inspected the unloading pad, containment dikes, tanks, injection line, pump house, annulus pressure, and injection pressure. Both containment dikes have oil and water in them. Both containment dikes have oil covered leaves and debris. Remove oil, water and contaminated debris from the containment dikes. The unloading pad containment vault has contamination around the top of the vault. Remove the contaminated material. All solids that are removed must be taken to an EPA approved land fill for disposal. The unloading pad drain has a screw in plug that is blocking the drain. Remove the plug and allow the containment pad drain to function as designed.
0935642072 2009-06-02 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # -563611421 FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed on the injection side of the well. The iden
0937568820 2015-06-24 Enhanced Recovery Project No Violations Compliance Notice Follow up. Hocking Hills brine truck removing the fluids from the containment dike. Currently excavating the contaminated soil outside of the containment dike. A roll off container from Farmers Refuse is on site. One injection line leak has been repaired. Attempted to fill and test the injection line. Was not able to pressure up the injection line to test. Company is deciding what remedial action they will take for the injection line.
0989670404 2019-04-29 Enhanced Recovery Project Violations Noted Our records indicate that the Division has not received the Enhanced Recovery Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019.
1006309625 2009-09-04 Enhanced Recovery Project No Violations A follow-up inspection to Notice of Violation and Compliance Schedule revealed no pressure on the annulus.
1019877444 2012-09-14 Surface Facility Construction No Violations Witnessed grading of dirt around containment dike, and the installation of steel walkways.
1034836549 2007-12-05 Enhanced Recovery Project No Violations Checked on the status of project. During the inspection, it was noted that a 210 bbl tank has been placed inside the dike. A 100 bbl tank was observed outside the dike. Doug Kitchen had been previously instructed to submit a new design to Tom Tomastik.
1043494133 2006-10-26 Enhanced Recovery Project No Violations The packer was set at 2833 A pressure test was performed on the annulus between longstring and tubing. The well passed and lost only 1 psi (660 to 659) in fifteen minutes.
1074673853 2016-11-14 Enhanced Recovery Project No Violations Chiefs Order # 2015-445 follow up inspection. The containment dike has 12 inches of fluid in it. The injection tubing is not connected to an injection line or injection equipment. Vegetative cover has been established on the remediated area.
1106575165 2005-01-20 Annular Disposal No Violations Checked AD for Columbus, AD not hooked up. NEW LAT & LONG
1116586588 2009-06-02 Enhanced Recovery Project Violations Noted An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed on the injection side of the well. The identification at the well does not contain the ERP #. No identification was observed at the storage tank. The contractor for Chieftain Energy., Mr. Ron McBride, was notified of the deficiencies, in person, on 6/2/2009 at approximately 12:30 pm.
1117182163 2018-05-04 Enhanced Recovery Project Violations Noted Our records indicate that the Division has not received the 2017 Enhanced Recovery Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Form 204 received 6/27/2018
1123703794 2019-01-28 Salt Water Injection Well No Violations My inspection was to determine if the water in the containment dike at this salt water injection well contained chlorides. I tested the water in the containment dike in two areas using high quantabs and did not detect any chlorides using the high range quantabs.
1126947469 2020-5-14 0:00: ER No Violations 1.00
1131589331 2013-11-25 Enhanced Recovery Project No Violations Inspected the containment dikes, tanks, unloading pad, pump house, injection line, injection pressure, and annulus pressure. Identification has not been changed to reflect the current well owner Hocking Hills Energy Well Service. The pump house has been severely damaged by fire. I called and talked to Dale Campbell. Dale stated that the fire was caused by a lightning strike that followed the electric line into the pump house. We discussed the need for them to notify the state when damage occurs to their facility. We also discussed the need for updated identification. They also need to replace the 1/4 fitting on the injection tubing. The threads are corroded. Flow meter is in gallons.
1162229060 2006-10-25 Enhanced Recovery Project No Violations On 10/25/2006, UIC construction was observed. 2 3/8 tubing is being pulled.
1165834760 2013-04-10 Salt Water Injection Well No Violations UIC training with Jon Scott, see Jon Scotts reports for details.
1167754030 2012-02-23 Surface Facility Construction No Violations Pit construction. 4 to 6 layer of sand below the 30 mil liner. 30 mil liner has been installed. 4 to 6 of sand on top of liner.
1188409674 2007-08-29 Surface Facility Construction No Violations Checked on surface facility construction. Dike has been constructed and witnessed installation of 30 mil liner.
1212564332 2009-03-03 Enhanced Recovery Project No Violations An inspection revealed no annulus pressure or identification at the storage tank. Chieftain Energy will be instructed to correct these deficiencies before the next inspection.
1216155987 2008-07-15 Enhanced Recovery Project No Violations An inspection revealed that Doug Kitchen is performing cleanup around the well site.
1219146359 2012-08-20 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # -1767643327 Annulus pressure 0. Company needs to perform full hydrostatic test to prove mechanical integrity. The tape on the seam on the new piece of liner also needs finished. Spoke with Dave Poling about these issue. He stated that they had been working on other wells and will get on those issues as soon as possible.
1230306936 2010-06-15 Enhanced Recovery Project No Violations Witnessed Injection Line Test. All leaks have been addressed and check valve flap removed. The line did not contain a brass Y strainer this time, due to crack. Mr. Ron McBride with Chieftain Energy states it will be replaced with steel.
1245201387 2012-06-13 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # 1651780143 Construction of a 12 by 14 block pump house on an 8 thick concrete slab with in the original dike. Dike contains a black steel horizontal tank that measures 27 by 8. Dike measures 48 by 26.5. Dike has a build up of sand in middle of dike. Dike has had recent oil in dike and oil has flowed to top of the lowest portion of dike. A new sump pump has been installed in both dikes and concrete vault for unloading pad. Inspection of the well revealed slight vacuum on the annulus. Doug Kitchen was notified in person at the well site that he needs to test the annulus to the maximum injection pressure for 15 minutes. Doug was also notified that he needs to replace the 1/4 injection fitting. (threads are stripped out.)
1250352730 2012-07-06 Surface Facility Construction No Violations Pump has been placed inside block building. Currently installing electric panel and conduit. Dike liner on site to repair and extend liner over raised dike wall. Talked to Doug Kitchen about the flow meter that needs to be installed between the pump and the well.
1321971689 2015-07-10 Enhanced Recovery Project No Violations Compliance Notice # 1412190582 follow up inspection. Contaminated soil is in a roll off container with a tarp install on top. The roll off material has been sampled for a profile and is waiting for the sample results before being taken to the landfill. Contaminated material has been removed from the containment dikes. The cement pieces from the unloading pad demolition is in a pile with a dike built around it waiting on another roll off container. Reviewed the cleanup efforts and facility plans with Shawn Maynard.
1326364925 2009-06-02 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # -1381541048 FOLLOW UP TO NOV # 682000589 -1116586588 FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed
1331135735 2012-02-08 Enhanced Recovery Project No Violations Constructing new dike. Meet with Doug Kitchen about dike specifications.
1334059463 2012-03-29 Enhanced Recovery Project No Violations An inspection revealed that the dike and the vault were full of fluid. A call was made to Mr. Ron McBride of Chieftain energy and violation was resolved immediately.
1335959289 2012-05-01 Enhanced Recovery Project No Violations Inspected condition of dike. It was free of fluid.
1340138117 2012-06-18 Salt Water Injection Well No Violations Mechanical integrity test of the annulus. Annulus took 1 gallon of fresh water to fill up. Tested annulus at 730 psi for 15 minutes after 15 minutes test pressure at 728 psi. Test passed. Tubing and packer were not effected during the test. Accompanied by Andy Thomas MRI 2. Discussed with Doug Kitchen and Ron McBride raising the dike wall to add capacity to dike since the addition of the concrete pad and block pump house to the original dike.
1340209395 2012-06-20 Surface Facility Construction No Violations Ron McBride has removed the soil from the outside edge of the dike liner. They have removed the majority of the contaminated sand from inside the dike. The liner has been folded into the dike to allow build up of dike wall. They are currently building up the dike wall to 34.
1340798557 2012-06-18 Enhanced Recovery Project No Violations Witnessed mechanical integrity test on the annulus. Accompanied by inspector Jon Scott. Test was passed.
1340923675 2012-06-27 Surface Facility Construction No Violations Original dike with Horizontal tank has been built up to 34 around the outside wall. I talked to Ron McBride about the flow meter. Checked the injection pressure and the annulus. Annulus was on zero pressure. Annulus fluid level is at surface.
1341498904 2012-06-13 Enhanced Recovery Project Violations Noted Construction of a 12 by 14 block pump house on an 8 thick concrete slab with in the original dike. Dike contains a black steel horizontal tank that measures 27 by 8. Dike measures 48 by 26.5. Dike has a build up of sand in middle of dike. Dike has had recent oil in dike and oil has flowed to top of the lowest portion of dike. A new sump pump has been installed in both dikes and concrete vault for unloading pad. Inspection of the well revealed slight vacuum on the annulus. Doug Kitchen was notified in person at the well site that he needs to test the annulus to the maximum injection pressure for 15 minutes. Doug was also notified that he needs to replace the 1/4 injection fitting. (threads are stripped out.)
1341836748 2012-06-27 Surface Facility Construction No Violations Inspected work in progress with inspector Jon Scott.
1343069615 2012-07-19 Surface Facility Construction No Violations Inspected tank battery containment liner where it had been patched and added on to. Some of the seams had bubbles in them and the liner had pulled away from the tape. I told the company that this had to remedied before it was covered. We then discussed ways of fixing it. I also observed some of the plumbing as it was assembled. We also discussed the placement of a flow meter.
134367124 2018-1-18 0:00: SW No Violations 1.00
1347469692 2012-09-06 Enhanced Recovery Project No Violations Witnessed mechanical integrity test on the annulus. A new rubber seal was put on the wellhead, then annulus was pressured up to 680 psi using a hand pump. Pressure was held for 15 minutes with no loss.
1353175915 2012-02-08 Enhanced Recovery Project No Violations Accompanied Inspector Jon Scott on an inspection of the construction of a new tank battery containment for this well. Met with Mr. Doug Kitchen from Chieftain Energy at the site.
1358435665 2013-01-14 Enhanced Recovery Project No Violations This is a follow-up inspection to the compliance notice that was issued by Jon Scott UIC Inspector III on 1/11/13. The contaminated soil around the unloading pad vault has been removed. The contaminated leaves and some of the contaminated sand has been removed. New sand has been placed in the dike in the areas that contaminated sand has been removed. Spoke with company men Mr. Bill Deible and Mr. Bryan Campbell. We discussed plans of remediation for the rest of the site including the sump system for the containment dikes and the vault and the removal and replacement of the horizontal tank. I told them to make sure that a drawing of what they planned to do was submitted the UIC section in Columbus.
1358449690 2013-01-15 Enhanced Recovery Project No Violations More contaminated sand had been taken out of the dike and replaced with clean sand. Remedial work had cease for half of a day due to their backhoe breaking down. Accompanied Jon Scott UIC Inspector III on this inspection.
1358955718 2013-01-15 Enhanced Recovery Project No Violations Both dikes are free of water and oil. All of the oil coated leaves have been removed from the dike. Contaminated sand is being removed and placed in a dump truck on site. New sand is being placed in the dike. Dike clean up is 2/3 completed. The contaminated soil around the unloading pad vault has been removed and replaced with fresh soil. All contaminated soil, leaves and sand are to be hauled to a EPA approved land fill. Accompanied by Andy Thomas MRI 2.
1360242401 2013-02-06 Salt Water Injection Well No Violations Assisted Jon Scott UIC inspector III, in taking a brine sample from the pump house. I checked the pressures at the well. Also present during this inspection was Mr. Bill Deible. Flow meter reading is in gallons. We also discussed with Mr. Deible the sump pump situation with the two containment dikes and the vault for the unloading pad.
1360610363 2013-02-11 Enhanced Recovery Project No Violations Inspected the plumbing of the sump pumps in the tank battery and the vault for the unloading pad. Each of the three sump pumps are now plumbed separately into the horizontal tank and the 280 barrel tank. I also showed Mr. Bill Deible how to monitor the annulus and injection pressures using his companys gauges.
1366586631 2008-07-25 Production Wells No Violations Checked on status of surface facility construction. No activity or progress was observed.
1379345853 2013-09-16 Salt Water Injection Well No Violations UIC inspection, the annulus pressure was 182 PSI, the injection pressure was 0 PSI. The dike contained approx 12 of water. The sump pump was not plugged in. I contacted Bill Diebel to have this corrected.
1381541048 2009-06-02 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # 682000589 -1116586588 FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed
1390555228 2014-03-11 Salt Water Injection Well No Violations UIC inspection, the injection is on vacuum, the annulus has 75 PSI. No violations noted.
1398181444 2014-04-22 Enhanced Recovery Project No Violations Compliance Notice # 930934140 Follow up inspection. Inspected the unloading pad, containment dikes, tanks, injection line, pump house, annulus pressure, and injection pressure. Both containment dikes have oil and water in them. Both containment dikes have oil covered leaves and debris. Some work has been done since the last inspection. The 4 plug in the unloading pad drain has been removed. A leaking valve on the 300 barrel tank has been repaired. A small portion of the contaminated leaves with in the containment dikes has been moved into piles. The access road has some new gravel on it near the well site. I called Dale Campbell and left a voice message asking why the clean up has not been done and outlining the work that still needs to be done to be in compliance. I left my phone number and asked that he call me. I called Bill Diebel (well tender) and Bill told me that he fixed the valve that caused the leak in the one containment and that he is working on cleaning up both dikes. I reviewed the work that still needs to be done with Bill.
1398702649 2014-04-28 Enhanced Recovery Project No Violations Compliance Notice # 930934140 Follow up inspection. 90% of the oil has been removed from the containment dikes. 80% of the contaminated leaves have been removed from the containment dike. Cleanup is not completed.
1400001286 2014-05-13 Enhanced Recovery Project No Violations Compliance Notice # 930934140 Follow up inspection. All of the oil has been removed from the containment dikes. All of the contaminated leaves have been removed from the containment dikes. Both dikes are free of water. The plumbing and use of the black horizontal tank has been changed to only store water that has been pumped from the containment dike sumps and the unloading pad sump. Bill Deible was on site during the inspection we discussed the need to upgrade the unloading pad drain vault. The current vault allows surface water during a rain event to enter the top of the vault and has overflowed the vault in the past.
1412190582 2014-10-01 Enhanced Recovery Project Violations Noted Inspected the unloading pad, containment dikes, tanks, injection line, annulus pressure and injection pressure. A scald area was observed outside the containment dikes. Approximately 75 by 3. Soil was field tested for chlorides. High range Quantab was maxed out at 6508 ppm Cl. I called Bill Diebel and he came out to the well site. I told Bill that the contaminated area must be remediated. The unloading pad sump had overflowed as well. I told Bill that the sump needs to be upgraded to prevent surface water from flowing into the top of the sump pit. I called Dave Poling and discussed the sump pit issues and what was needed to remediate the contaminated areas. I told Dave that the sump must be one piece construction with the top extending at least 6 above the ground level.
1413911093 2014-10-21 Enhanced Recovery Project No Violations Compliance notice # 1412190582. Inspected the unloading pad, vault, containment dikes, tanks, injection pressure and annulus pressure. There were no noticeable efforts to remediate the contaminated areas outside the containment dikes. A high range Quantab was placed in a puddle with in the contaminated area it read 7.8 on the strip which is 3220 ppm Cl. The unloading pad vault has not been replaced.
1414004439 2014-10-22 Enhanced Recovery Project No Violations The injection operations have stopped until the surface facility is reworked. I talked to Dave Poling and they are planning an extensive remodel of the existing surface facility. Dave is going to submit for an extension.
1414676143 2014-10-29 Administrative Inspection No Violations I received this Email from Dave Poling on 10-29-14. Mr. Scott:

This email is to inform you that the ERP well owned by Hocking Hills Energy & Well Services, LLC is offline, shut down and not in operation at this time. We are evaluating the current configuration of the well, tank system, unloading area and roadway. Your concern about the pit behind the unloading area is understood and will be addressed as we perform the upgrade. Shortly, a drawing will be forwarded to you for your input and thoughts. Let me know if you have any other concerns.

Dave Poling, Member Hocking Hills Energy & Well Services, LLC

1421544494 2015-09-17 Enhanced Recovery Project No Violations Both containment dikes have water in them. There has been no effort to remove the contaminated material from the location since the last inspection on 9-14-15. No equipment is on site for the remediation. There are no roll off boxes on site.
1432912921 2014-03-20 Salt Water Injection Well No Violations Compliance notice follow-up. The well is in compliance, this satisfies the compliance notice.
1434723267 2015-06-18 Enhanced Recovery Project Violations Noted
1436302375 2015-07-06 Enhanced Recovery Project No Violations Compliance Notice # 1412190582 follow up inspection. UST Environmental Contractor arrived on site with a vac truck to remove material from the black horizontal tank and to clean out contaminated material. A roll off container on site was not covered with a tarp and contaminated soil and used filter socks were mixed with rain water. Hocking Hills Energy is using their vac truck to remove the water from the roll off box. Both containment dikes have water and oil in them. The dikes are being cleaned using the UST truck and labor. Doug Kitchen is operating the trac hoe and has removed the unloading pad and unloading pad sump. This material along with additional excavated contaminated soil is being placed in roll off containers and shipped to the landfill. All injection equipment and valves are shut off. All solids are being placed in the roll off box and all liquids are being pumped into the 300 barrel tank with in the containment dike. Plans have been submitted to the UIC section for review regarding the new unloading pad and containment dike construction.
1443450631 2015-09-28 Salt Water Injection Well No Violations Hocking Hills Energy has finished removing contaminated soil. The existing tanks are being pressure washed. The last container containing soil has been taken to the landfill.
1444059611 2015-10-02 Enhanced Recovery Project No Violations Chiefs Order # 2015 445 Follow up inspection. Collected field soil samples and tested with High Range Quantabs. Sampled at GPS N39.48999/W082.39807 Sample was collected from the center of the triangle scald area off of the access road measuring 44 by 34 by 26. Quantab result was 7.2 on the strip =2986 ppm Cl. Collected a sample at GPS N39.48898/W082.39716 The Quantab result was 3.6 on the strip = 650 ppm Cl. Collected a sample at GPS N39.48885/W082.39716 The Quantab result was 5.8 on the strip = 1630 ppm Cl. The containment dike with the pump house has been excavated and the material removed from the location. Waiting on documentation of disposal in an EPA approved landfill. The area that was delineated with red flags has had soil brought in and graded with seed and mulch applied. The existing containment dike has 12 of fluid in it. Well is completely disconnected from the tanks and any injection equipment.
1444403726 2015-10-08 Enhanced Recovery Project No Violations Chiefs Order # 2015-445 follow up inspection. Collected soil and water samples from the location and took them to the ODNR Lab. Containment dike has 12 of fluid in it. The well is disconnected from all injection equipment.
1448638331 2015-11-25 Enhanced Recovery Project No Violations Chief Order No. 2015-445 Follow-Up inspection. Injection tubing master valve is closed. Injection tubing is not connected to injection line or equipment. The containment dike has 16 of water in it. Annulus has zero pressure with fluid at surface. Vegetative cover is being established on most of the remediation site. Five areas of water on the surface were tested for chlorides with High Range Quantabs (QT). QT # 1= 1630 ppm Cl. QT # 2= 917 ppm Cl. (both QT 1 & 2 were East of the injection well). QT # 3= 917 ppm Cl. QT # 4= 1501 ppm Cl. (QT3 &4 are located West of the injection well and South of the containment dike). QT #5=400 ppm Cl. (located North west of the well).
1461494217 2012-11-27 Enhanced Recovery Project No Violations The dikes for both tank batteries were free of fluid and had vegetation established on the sides of them as well. Mr. Bill Deible and Bryan Campbell were on site. The flowmeter reading is in gallons.
146196985 2011-12-15 0:00 ER No Violations
1462468369 2016-05-03 Enhanced Recovery Project No Violations Chief Order # 2015-445 Follow up inspection with UIC Supervisor. The containment dike plastic liner has multiple holes including large holes (6-8) where the top of a tree fell into the dike. The dike has fluid in it. There is a scald area approximately 12 by 25. The well is disconnected from injection equipment. The injection tubing master valve is closed. The annulus has zero pressure.
1469536062 2016-07-22 Enhanced Recovery Project No Violations Chief Order # 2015-445 follow up inspection. The remediation of the contaminated area out side of the dike area is complete. Vegetative cover has been established. The containment dike has 20 inches of fluid in it. The injection tubing is not connected to the facility. The annulus has zero pressure.
1474189227 2011-07-06 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # -897437627 Zero pressure on injection tubing. Zero pressure on annulus. Test Annulus to 675 psi for 15 minutes. Schedule test with Jon Scott MRI2 740-624-4963. Brine on wellhead maxed out High End Quantabs. Repair or replace tubing at wellhead. Brine in dike. Remove brine from dike and dispose in an Injection well. Replace 1/4 needle valve on Injection tubing.
1478404728 2013-02-06 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Inspected the storage tanks and pump house. Collected brine sample and sent sample to lab. Accompanied by Andy Thomas MRI 2.
1483595985 2015-06-22 Enhanced Recovery Project No Violations Compliance Notice # 1412190582 Follow up inspection. Containment dikes have not been emptied. There is a backhoe on site. No excavation has been done to the contaminated areas. The only change to the site that was noticed was the grass has been cut around the dikes.
1485677477 2004-09-28 Annular Disposal No Violations Follow-up, Non-Compliance, Doug Kiycken and Joe Hoerst on inspection.
1490803259 2017-03-20 Enhanced Recovery Project No Violations Chief Order # 2015-445 Follow up Inspection. The containment dike has 8 inches of fluid in it. The well is not connected to an injection line or injection pump. The injection tubing master valve is closed.
1491156159 2015-07-30 Enhanced Recovery Project No Violations Both containment dikes had water and one had water and oil. The contaminated soil in the roll off box is on site. No additional work has been done to the contaminated areas. Six areas were selected to use High Range Quantabs to determine the chloride levels. 1st 5392 ppm Cl, 2nd, 3rd and 4th exceeded 6078 ppm Cl. 5th 3214 ppm cl, 6th 1613 ppm Cl. There was no activity at the site today. No additional contamination has been remediated. The unloading pad has been removed and is piled up on the ground. There has been no new construction on the site. Inspected the injection pressure and the annulus pressure. The injection line is disconnected at the containment dike.
1508293519 2008-05-22 Enhanced Recovery Project No Violations An inspection revealed that the suface facility construction has not been completed. No pressure observed on annulus or injection side of the well.
1549989250 2019-02-12 Salt Water Injection Well No Violations I conducted a status check to observe the fluid in the dike for the tank battery. The dike was full of fluid and had an approximate 1 inch layer of ice. It was raining during the inspection and had been raining since the previous day. Time of inspection: 9:00 AM. Weather: 46 degrees F, Rain
156012850 2010-6-10 0:00: ER No Violations
1585283855 2012-06-25 Surface Facility Construction No Violations Witnessed dike augmentation activities. Discussed with Mr. Doug Kitchen possibilities for adding to the existing liner so that it will drape over the top and sides of the dike.
1592764413 2012-02-23 Enhanced Recovery Project No Violations Witnessed placement of the liner in the new containment dike and placement of sand on top of the liner. Accompanied by Inspector Jon Scott.
1609198785 2009-07-20 Enhanced Recovery Project No Violations A follow-up inspection to Notice of Violation and Compliance Agreement Schedule revealed that identification has now been placed at the well and storage tank. However, there is still no pressure on the annulus. Prior to this inspection, a 7/14/2009 meeting had been conducted with both Mr. Doug Kitchen, the well owner, and Mr. Ron McBride, Chieftain Energy Contractor. During the meeting a Compliance Schedule was agreed upon by both parties. The deadline for compliance was 7/17/2009. Mr. McBride states that he placed 50 lbs of pressure on the annulus. Mr. McBride was instructed to check for leaks and again place more pressure on the annulus.
1619954482 2003-05-29 Annular Disposal No Violations Follow-up, Non-Compliance, company still has some leveling and seeding to do, kill area still below production tank. Spoke with Doug Kitchen will have work done by 6/2/03.
1625747241 2009-06-02 Enhanced Recovery Project No Violations FOLLOW UP TO NOV # 682000589 FOLLOW UP TO NOV # -1116586588 An inspection of the ERP and related storage tank was conducted with Mr. Jeff Fry. During the inspection, it was noted that the annular side of the well did not contain positive pressure. Vacuum was observed on the injection side of the well. The identification at the well missing ERP # and need ID at tank.
1651780143 2012-06-13 Enhanced Recovery Project No Violations Construction of a 12 by 14 block pump house on an 8 thick concrete slab with in the original dike. Dike contains a black steel horizontal tank that measures 27 by 8. Dike measures 48 by 26.5. Dike has a build up of sand in middle of dike. Dike has had recent oil in dike and oil has flowed to top of the lowest portion of dike. A new sump pump has been installed in both dikes and concrete vault for unloading pad. Inspection of the well revealed slight vacuum on the annulus. Doug Kitchen was notified in person at the well site that he needs to test the annulus to the maximum injection pressure for 15 minutes. Doug was also notified that he needs to replace the 1/4 injection fitting. (threads are stripped out.)
1676404973 2013-07-03 Salt Water Injection Well No Violations Injection well inspection, the annulus pressure was 246 PSI, the injection side is on vacuum. The dike has approx 4 of water in it. I have contacted Seneca Steel to have the fresh water removed from the dike. Bill Diebel has agreed to remove the fresh water today.
1712197945 2010-05-14 Enhanced Recovery Project No Violations A follow-up inspection revealed non-compliance. Arrived at the location and met with Chieftain Energy Contractor, Mr. Ron McBride. The pressure on the injection line from tank to well (disconnected) was at approximately 400 psi and dropping. At this time, Mr. McBride is unable to achieve the required maximum injection pressure of 675 psi to test line. Mr. McBride states that the line is full, but the pump will continually shut down. He was instructed that injection is not allowed at this time. The line must pass the required test prior to injection. The dike has been pumped and nearby gas line from non-related well has now been repaired. Informed Mr McBride that well site and lease road need to be graded.
1724006903 2006-03-29 Annular Disposal No Violations An inspection of the well and well site was performed for the UIC Section, company has applied for a Enhanced Recovery Project on this well, after reviewing site and speaking with Owner Doug Kitchen about location of Surface Facility, fencing should be pl
1766418051 2009-01-21 Surface Facility Construction No Violations An inspection revealed that the surface facility construction has now been completed. Chieftain Energy has been instructed to place positive pressure on the annulus, and identification at the storage tank.
1767643327 2012-08-20 Enhanced Recovery Project Violations Noted Annulus pressure 0. Company needs to perform full hydrostatic test to prove mechanical integrity. The tape on the seam on the new piece of liner also needs finished. Spoke with Dave Poling about these issue. He stated that they had been working on other wells and will get on those issues as soon as possible.
1770508949 2006-06-19 Enhanced Recovery Project No Violations No violations were found at the time of the inspection. The enhanced recovery project has not been completed for this well.
1775057382 2019-04-03 Salt Water Injection Well No Violations My inspection was at the request of well owner, Mr. Doug Kitchen. Mr.Kitchen requested I performed a mechanical integrity test on the well. The test was held for 15 minutes with 698 PSI on the injection tubing. The well did not lose any pressure during the 15 minute test. The containment dike was free of fluid but had approximately 1 foot of leaf litter. Mr. Kitchen said the leaf litter would be removed today.
1776951922 2012-06-26 Surface Facility Construction No Violations Crews were plumbing lines back in. Dirt work for dike had been completed.
1799809297 2015-09-24 Salt Water Injection Well No Violations Hocking Hills Energy has removed the block pump house and all associated plumbing. The contaminant dike has been removed and the effected soil has been taken to kilbargers landfill. I have tested the remaining soil for chlorides and will continue to do so during demolition.
1812844999 2012-06-20 Surface Facility Construction No Violations Witnessed crews moving dirt to raise the walls of the dike around one of the tank batteries.
1826542234 2012-06-06 Enhanced Recovery Project No Violations Two tanks have been set in new containment dike. One being a 210 barrel and the other is a 280 barrel tank. The tanks have been plumbed in and are ready to be used. A new concrete pad has been poured in the original containment dike. New photos were taken during inspection.
1834966995 2011-12-15 Enhanced Recovery Project No Violations Accompanied Jon Scott on inspection. Needs new needle valve for injection pressure monitoring. Dike full of water. New photos obtained during inspection.
1861170286 2016-06-03 Salt Water Injection Well No Violations Hocking Hills Energy has removed soil that is contaminated with brine. The soil was tested using Quantabs. Average results using the Quantabs was 500-900 PPM chlorides. The area was backfilled with topsoil and seeded.
1862013710 2008-07-15 Enhanced Recovery Project No Violations Met with Mr. Doug Kitchen at the well site. Mr. Kitchen was shown the impacted areas and instructed to remove contaminated soil and bring in new soil, seed, straw and apply lime to these areas. Mr. Kitchen was again verbally instructed to complete surface facility before injection.
1874240395 2011-03-31 Enhanced Recovery Project No Violations No violations observed during inspection.
1883916871 2012-07-31 Surface Facility Construction No Violations Inspected installation of new flow meter. I noticed fluid in the containment dike. I notified Mr. Doug Kitchen immediately (he was on site at the time). He stated that he had to fix the float on the sump pump so that it would pump the fluid down to a lower level.
1904628193 2019-3-13 0:00: ER No Violations
1921632420 2015-01-28 Salt Water Injection Well No Violations UIC inspection, the annulus pressure was 46 PSI, the injection pressure was 0 PSI.
1923010994 2013-04-10 Enhanced Recovery Project No Violations Inspected containment dikes, injection pressure and annulus pressure. Good identification on well. Dikes are free of water. A small amount of oil (approximately 2 gallons) has leaked from the top of the horizontal tank. I talked to Doug Kitchen about the need to repair the tank so that it does not leak oil into the dike. The unloading pad had some sludge from cleaning the filters. I told Doug to clean up the sludge on the unloading pad. Flow meter reading is in gallons. Accompanied by Kip Thompson MRI 2.
1936973023 2008-09-17 Enhanced Recovery Project No Violations An inspection revealed that the surface facility has not been completed. 1/4 valves have been installed on injection and annulus side of the well. No annulus pressure observed.
1944722098 2012-08-07 Surface Facility Construction No Violations Inspected the patches being put on the liner in the containment dike. Accompanied by inspector Morgan Button.
1984598286 2012-07-06 Surface Facility Construction No Violations Witnessed new injection pump being set. During the inspection, I noticed leaching of fluid from bottom of dike. Inside of the dike fluid was present. The liner was still folded inside the dike. Due to recent rain events fluid had made it over the liner and caused the problem. Doug Kitchen and Bill Deible were instructed to remove fluid from inside of dike before the end of the day.
2016531117 2018-05-21 Salt Water Injection Well No Violations The salt water injection well had 81 psi on the annulus and 0 psi on the injection tubing. The well had a legible identification.
2026205392 2007-06-26 Surface Facility Construction No Violations Met with Chieftain Energy, regarding the UIC construction requirements for this ERP. The company was informed of the dike requirements including the concrete vault with sump (coated), 30 millimeter liner and fence. Measurements revealed that more work will be needed on the dike. It was noted that the dike height would need to be raised approximately 2 inches to meet the 32 inch requirement.
2049404676 2012-02-22 Surface Facility Construction No Violations Constructing new dike.
2094271860 2010-12-28 Enhanced Recovery Project No Violations An inspection revealed no violations. Snow cover at time of inspection.
2097609832 2016-03-17 Enhanced Recovery Project Violations Noted Our records indicate that the Division has not received the Enhanced Recovery Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. reports received
2129194491 2014-04-09 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # 930934140 Inspected the unloading pad, containment dikes, tanks, injection line, pump house, annulus pressure, and injection pressure. Both containment dikes have oil and water in them. Both containment dikes have oil covered leaves and debris. Remove oil, water and contaminated debris from the containment dikes. The unloading pad containment vault has contamination around the top of the vault. Remove the contaminated material. All solids that are removed must be taken to an EPA approved land fill for disposal. The unloading pad drain has a screw in plug that is blocking the drain. Remove the plug and allow the containment pad drain to function as designed.
2146088841 2015-09-14 Enhanced Recovery Project No Violations Compliance Notice Follow up. 2/3rds of the water in the containment dikes has been removed. No contaminated material has been removed from the location. There has been no activity except the removal of water and oil from the dikes. No roll off boxes or excavating equipment is on site.
224425600 2009-12-3 0:00: ER No Violations
261149307 2012-7-13 0:00: SC No Violations 1.50
278715626 2010-9-7 0:00:0 BH No Violations
298240305 2010-9-22 0:00: ER No Violations 1.00
31053836 2007-7-30 0:00: SC No Violations
331422685 2016-2-3 0:00:0 ER No Violations 2.00
359615844 2015-12-31 0:00 ER No Violations 4.00
375637493 2008-8-8 0:00:0 ER No Violations
378216293 2008-12-8 0:00: SC No Violations
388118204 2012-2-22 0:00: ER No Violations 4.00
390510777 2016-6-15 0:00: ER No Violations 1.00
395669655 2006-6-19 0:00: ER No Violations
40479472 2010-3-12 0:00: ER No Violations
475214848 2018-8-7 0:00:0 ER No Violations 1.00
57766270 2011-2-1 0:00:0 ER No Violations 0.50
596856320 2014-8-4 0:00:0 SW No Violations 0.20
62416454 2008-11-25 0:00 SC No Violations
640176974 2008-6-16 0:00: ER No Violations
682000589 2009-6-2 0:00:0 ER No Violations
714685875 2013-2-6 0:00:0 ER No Violations
716073848 2015-9-8 0:00:0 ER No Violations 5.00
71971176 2016-3-21 0:00: ER No Violations 3.00
739028801 2016-6-2 0:00:0 SW No Violations 8.00
755009655 2004-11-26 0:00 AD No Violations
930934140 2014-4-9 0:00:0 ER No Violations 3.50
935642072 2009-6-2 0:00:0 ER No Violations
937568820 2015-6-24 0:00: ER No Violations 5.50
989670404 2019-4-29 0:00: ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0278715626 US-OH-122890 2010-10-06 Pollution and contamination
0278715626 US-OH-122891 2010-10-06 Spreading brine on unapproved road surfaces
0278715626 US-OH-122892 2010-10-06 Spreading of an unapproved fluid
0278715626 US-OH-122893 2010-10-06 Pollution/Contamination
0278715626 US-OH-122894 2010-10-06 Contamination at storage facility (permit after 6/1/82)
0581161508 US-OH-126520 2013-02-08 Pollution/Contamination
0581161508 US-OH-126521 2013-02-08 Storage facilities contamination (permit before 6/1/82)
0595775573 US-OH-126717 2018-09-13 9-5-09[C] Failure to conduct or pass mech. integrity test
0640176974 US-OH-127257 2008-07-15 Pollution/Contamination
0646446501 US-OH-127332 2004-05-17 Well operation causing pollution and contamination
0646446501 US-OH-127333 2004-05-17 Failure to legibly identify well
0897437627 US-OH-130230 2011-07-07 Failure to monitor annulus pressure
0897437627 US-OH-130231 2011-07-07 Mechanical failure/contamination
0897437627 US-OH-130232 2011-07-07 Failure to keep dike or pit free of brine or other wastes
0930934140 US-OH-130644 2014-05-20 Pollution/Contamination
0930934140 US-OH-130645 2014-05-20 Contamination at storage facility (permit after 6/1/82)
0935642072 US-OH-130709 2018-03-23 Failure to conduct or pass mech. integrity test
0989670404 US-OH-131364 2019-05-09 Failure to file enhanced recovery annual report
1116586588 US-OH-102933 2009-06-08 Failure to monitor annulus pressure
1116586588 US-OH-102934 2009-06-08 Insufficient/No identification
1117182163 US-OH-102956 2018-08-03 Failure to file enhanced recovery annual report
1245201387 US-OH-106542 2018-09-13 9-5-09[C] Failure to conduct or pass mech. integrity test
1326364925 US-OH-109318 2017-10-23 Failure to conduct or pass mech. integrity test
1341498904 US-OH-109835 2012-07-05 Failure to monitor annulus pressure
1412190582 US-OH-112135 2016-08-26 Pollution/Contamination
1434723267 US-OH-112714 2015-07-17 Pollution/Contamination
1434723267 US-OH-112715 2015-07-17 Contamination at storage facility (permit after 6/1/82)
1767643327 US-OH-117591 2012-08-22 Failure to monitor annulus pressure
2097609832 US-OH-121411 2016-07-21 Failure to monitor pressures or volumes/failure to file
2129194491 US-OH-121814 2018-09-13 9-5-09[C] Failure to conduct or pass mech. integrity test

For data sources see[9]