34-073-22037

Well Details

Well ID: 34-073-22037
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: NUTTER LOWELL
License Status: Producing
License Date: 1977-11-28
Spud Date: 1977-11-30
Spud Drilling Contractor:
Final Drill Date: 1978-02-18
Well Total Depth: 2850.00 ft
Configuration: Vertical
Latitude: 39.540000
Longitude: -82.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1977-11-28 566 GRIM PAUL A GeoDate 11/28/77
Original Spud 1977-11-30
Completed 1978-02-18
Reached Total Depth 1978-02-18
Change of Owner 2001-10-29 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 10000 Bbl 15000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GRIM PAUL A 2457.00 449.00 365
1985 GRIM PAUL A 2773.00 351.00 365
1986 GRIM PAUL A 1016.00 104.00 365
1987 GRIM PAUL A 444.00 102.00 365
1988 GRIM PAUL A 103.00 76.00 365
1989 GRIM PAUL A 66.00 0.00 365
1990 GRIM PAUL A 59.00 31.00 365
1991 GRIM PAUL A 509.00 225.00 365
1992 GRIM PAUL A 942.00 210.00 365
1993 GRIM PAUL A 520.00 73.00 365
1994 GRIM PAUL A 338.00 102.00 365
1995 GRIM PAUL A 302.00 77.00 365
1996 GRIM PAUL A 256.00 160.00 365
1997 GRIM PAUL A 148.00 22.00 365
1998 GRIM PAUL A 0.00 0.00 365
1999 GRIM PAUL A 0.00 0.00 365
2000 GRIM PAUL A 0.00 95.00 365
2001 GRIM PAUL A 0.00 15.00 365
2002 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2003 HOCKING HILLS ENERGY AND WELL 0.00 9.00 10
2004 HOCKING HILLS ENERGY AND WELL 0.00 7.00 365
2005 HOCKING HILLS ENERGY AND WELL 0.00 11.00 365
2006 HOCKING HILLS ENERGY AND WELL 0.00 12.00 365
2007 HOCKING HILLS ENERGY AND WELL 0.00 38.00 365
2008 HOCKING HILLS ENERGY AND WELL 0.00 38.00 365
2009 HOCKING HILLS ENERGY AND WELL 0.00 38.00 365
2010 HOCKING HILLS ENERGY AND WELL 0.00 26.00 0
2011 HOCKING HILLS ENERGY AND WELL 0.00 54.00 365
2012 HOCKING HILLS ENERGY AND WELL 0.00 61.00 366
2013 HOCKING HILLS ENERGY AND WELL 0.00 84.00 365
2014 HOCKING HILLS ENERGY AND WELL 0.00 54.00 365
2015 HOCKING HILLS ENERGY AND WELL 0.00 27.00 365
2016 HOCKING HILLS ENERGY AND WELL 0.00 16.00 365
2017 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GRIM PAUL A Brine 0 365
1985 GRIM PAUL A Brine 365 365
1986 GRIM PAUL A Brine 0 365
1987 GRIM PAUL A Brine 0 365
1988 GRIM PAUL A Brine 0 365
1989 GRIM PAUL A Brine 0 365
1990 GRIM PAUL A Brine 0 365
1991 GRIM PAUL A Brine 0 365
1992 GRIM PAUL A Brine 28 365
1993 GRIM PAUL A Brine 44 365
1994 GRIM PAUL A Brine 80 365
1995 GRIM PAUL A Brine 70 365
1996 GRIM PAUL A Brine 600 365
1997 GRIM PAUL A Brine 56 365
1998 GRIM PAUL A Brine 40 365
1999 GRIM PAUL A Brine 0 365
2000 GRIM PAUL A Brine 140 365
2001 GRIM PAUL A Brine 70 365
2002 HOCKING HILLS ENERGY AND WELL Brine 0 0
2003 HOCKING HILLS ENERGY AND WELL Brine 20 10
2004 HOCKING HILLS ENERGY AND WELL Brine 42 365
2005 HOCKING HILLS ENERGY AND WELL Brine 55 365
2006 HOCKING HILLS ENERGY AND WELL Brine 0 365
2007 HOCKING HILLS ENERGY AND WELL Brine 30 365
2008 HOCKING HILLS ENERGY AND WELL Brine 30 365
2009 HOCKING HILLS ENERGY AND WELL Brine 30 365
2010 HOCKING HILLS ENERGY AND WELL Brine 24 0
2011 HOCKING HILLS ENERGY AND WELL Brine 38 365
2012 HOCKING HILLS ENERGY AND WELL Brine 300 366
2013 HOCKING HILLS ENERGY AND WELL Brine 238 365
2014 HOCKING HILLS ENERGY AND WELL Brine 322 365
2015 HOCKING HILLS ENERGY AND WELL Brine 26 365
2016 HOCKING HILLS ENERGY AND WELL Brine 25 365
2017 HOCKING HILLS ENERGY AND WELL Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1022460463 2006-8-15 0:00: PW No Violations
-1390459796 2003-12-23 0:00 PW No Violations
-183149576 2018-4-13 0:00: PW No Violations 0.20
-2064795585 2003-11-6 0:00: PW No Violations
-260086999 2006-10-18 0:00 PW No Violations
-564519403 2004-3-17 0:00: PW No Violations
-603960152 2009-3-17 0:00: PW No Violations
-648383629 2009-3-18 0:00: PW No Violations
0183149576 2018-04-13 Production Wells No Violations My inspection revealed the well consists of a pumping unit, vertical separator, 2-100 barrel tanks, 1-20 barrel tank and gas sales meter. This well shares a common tank battery with 3407321899. Legible identification was posted.
0260086999 2006-10-18 Production Wells Violations Noted A complaint was received alleging that the Parley and Lowell Nutter wells are idle. According to the owner of Chieftain Energy, Mr. Doug Kitchen, and the landowner, Mr. Lowell Nutter all seven wells are tied into each other to produce house gas. Mr. Nutter states that little gas is obtained from these wells. Mr. Kitchen admitted that a few wells need some work. Mr. Kitchen will be given credit for 1 well since some house gas is generated. The other 6 wells must be plugged or produced. Mr. Kitchen was given a verbal NOV on 10/18/2006.
0564519403 2004-03-17 Production Wells No Violations Follow-up on NOV, In-Compliance
0603960152 2009-03-17 Production Wells Violations Noted A complaint was received alleging that a flowline has leaked oil onto the ground surface, in a pasture field, located on Maysville Williams Road. An inspection revealed that a 2 steel flowline from this well has leaked and will need to be repaired. Approximately 30 (length) x 5 (width) of impacted area was observed in the pasture field. The impacted area includes a bare section and old oil that has broken down. Currently, the well is shut down and will not be pumped. Note: Class B Wastewater from the City of Logan is applied to the pasture field. The well owner has been contacted by telephone and instructed to perform repair and cleanup.
0648383629 2009-03-18 Production Wells No Violations A follow-up inspection revealed that peat sorb has been applied to the location,in the pasture field, alongside the road. Due to the drainage from roadside culvert pipe(s) onto the location, absorbent pads had been recommended to the company for locations alongside the road. No oil was observed inside the roadside culvert pipe. The company will be contacted by telephone and instructed to place pads at location. The well remains shut down and the flowline will still need to be repaired.
1022460463 2006-08-15 Production Wells Violations Noted An inspection was conducted at the facility owned by Chieftain Energy Corp on 8/15/2006. During the inspection, it was noted that the well utilized a common tank battery and no ID was observed at the well.
1081509298 2009-03-20 Production Wells No Violations A follow-up inspection revealed non-compliance.
1244523135 2009-04-06 Production Wells No Violations A follow-up inspection revealed that the flowline has been repaired. A new band clamp has been placed around the steel casing. Chieftain Energy has been informed that if line locations leak again, the lines would have to be replaced.
1390459796 2003-12-23 Production Wells No Violations Follow-up on NOV, Non-Compliance, company has not complied with NOV. 1/12/04 to date company has not complied with NOV and corrected violations, turned over to management.
1651922300 2017-06-30 Storage Well No Violations Columbia Gas storage well inspection. The well consists of a wellhead and a drip. Legible identification on wellhead, no violations noted, GPS was taken on day of inspection.
1883658488 2006-12-22 Production Wells No Violations A follow-up inspection revealed that the previously noted violation has been resolved. The well was observed pumping with no signs of mechanical problems.
2064795585 2003-11-06 Production Wells Violations Noted An inspection of the well revealed No ID at the well, oily soil in dike around tank battery, production tanks leaking around bottoms, fittings and seams. Dike does not meet SPCC requirements, not large enough. 1/12/04 to date company has not complied with NOV and corrected violations, turned over to management.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0260086999 US-OH-122681 2006-10-23 Well shall be plugged
0603960152 US-OH-126806 2009-04-13 Inadequate pipeline strength
0603960152 US-OH-126807 2009-04-13 Well operation causing pollution and contamination
1022460463 US-OH-100286 2006-08-29 Failure to legibly identify well
2064795585 US-OH-121040 2003-11-10 Well operation causing pollution and contamination
2064795585 US-OH-121041 2003-11-10 Failure to legibly identify well
2064795585 US-OH-121042 2003-11-10 Equipment pressure rated below operating pressure
2064795585 US-OH-121043 2003-11-10 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[8]