X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-21041

Well Details

Well ID: 34-073-21041
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Washington Township
Operator Name: POLING ALBERT
Well Pad ID:
Farm/Lease Name: STIVISON R D & F P
License Status: Producing
License Date: 1963-03-15
Spud Date: 1963-03-08
Spud Drilling Contractor:
Final Drill Date: 1963-04-10
Well Total Depth: 2785.00 ft
Configuration: Vertical
Latitude: 39.470000
Longitude: -82.420000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1801-01-02 283 POLING ALBERT
Oil and Gas 1802-01-01
Original Spud 1963-03-08
Completed 1963-04-10
Reached Total Depth 1963-04-10
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1000 Bbl 28000 R.P. 24 HRS.

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 POLING ALBERT 0.00 0.00 180
2009 POLING ALBERT 0.00 231.00 365
2012 POLING ALBERT 0.00 324.00 366
2013 POLING ALBERT 0.00 225.00 289
2014 POLING ALBERT 0.00 20.00 360
2016 POLING ALBERT 0.00 25.00 365
2017 POLING ALBERT 0.00 55.00 45

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 POLING ALBERT Brine 0 180
2009 POLING ALBERT Brine 0 365
2012 POLING ALBERT Brine 0 366
2013 POLING ALBERT Brine 0 289
2014 POLING ALBERT Brine 0 360
2016 POLING ALBERT Brine 0 365
2017 POLING ALBERT Brine 0 45

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1016410044 2013-11-6 0:00: PW No Violations 1.00
-1065226469 2013-3-27 0:00: PW No Violations 1.00
-1382260031 2013-1-9 0:00:0 PW No Violations 1.00
0015009782 2013-03-27 Production Wells No Violations Well is not in violation. Spoke with Mr. Albert Poling and his daughters boyfriend Jason. Accompanied by Inspector Kip Thompson.
1016410044 2013-11-06 Production Wells No Violations Compliance notice follow up. The wells production has been reported. This satisfies the compliance notice.
1065226469 2013-03-27 Production Wells No Violations Hocking county training with Andy Thomas.
1267684752 2010-02-02 Production Wells Violations Noted An inspection revealed 50 x 15 path of old oil (paraffin) over a hillside from the well location. Following the path of P&C, the source derives from the stuffing box. An earthen dike will be required at the well head. No identification observed at the well or tank. Currently, there are no statements of production for this well in RBDMS. The well consists of a pumping unit with production equipment at the well head. New motor with no belts observed on unit. A 3 hose connected from casing side of well routed to a separator containing 3/4 lines (2). A 3/4 line was also attached to the pumping tee side of well. A 6x 4x 3 steel box located behind the well with a 3/4 line attached at bottom then routed to top of lid. A 100 bbl tank was also located on the property. 2 steel was observed as the connection into top of tank. Unable to obtain GPS reading for well and tank, due to weak signal. Remove all contaminated material at the well location. Construct an earthen dike around the well head. Identification for the well and/or storage tank is required. The identification shall include well owner name, well name, well number, county, permit
1357910173 2013-01-09 Production Wells Violations Noted Well in operation at the time of inspection. There is a containment dike around the well head and there is 2-3 inches of fluid in it. Production has not been reported since 2009. Identification is posted on the pumping unit and the tank. The fluid around the well head was discussed with Mr. Albert Poling on 1/10/13 at 9:28 am via telephone. He keeps regular checks on it and will continue to keep it pumped out. We also discussed the issue of not reporting production and I gave him the number to call and get a hold of Patty Nicklaus at the Columbus office so that he can acquire the forms needed to do so. There is one 100 barrel tank that the well pumps in to. There are no compliance issues there. Production records need to be submitted for this well.
1382260031 2013-01-09 Production Wells No Violations FOLLOW UP TO NOV # 1357910173 Well in operation at the time of inspection. There is a containment dike around the well head and there is 2-3 inches of fluid in it. Production has not been reported since 2009. Identification is posted on the pumping unit and the tank. The fluid around the well head was discussed with Mr. Albert Poling on 1/10/13 at 9:28 am via telephone. He keeps regular checks on it and will continue to keep it pumped out. We also discussed the issue of not reporting production and I gave him the number to call and get a hold of Patty Nicklaus at the Columbus office so that he can acquire the forms needed to do so. There is one 100 barrel tank that the well pumps in to. There are no compliance issues there. Production records need to be submitted for this well.
1476912801 2010-04-12 Production Wells No Violations A follow-up inspection revealed non-compliance.
15009782 2013-3-27 0:00: PW No Violations 1.00
2046655195 2010-05-19 Production Wells No Violations A follow-up inspection revealed compliance.
2145974897 2019-04-18 Production Wells No Violations I conducted a status check on this well today. My inspection revealed that the well was not capable of production. It was equipped with a pumping unit and motor but the pumping unit was detached from the polish rod. There were no production lines connected to the pumping tee and I did not observe a belt on the gear box pulley. I contacted Albert Poling at 3:50 PM and advised him of my inspection. The well owner/operator shall submit a written plugging schedule to Brandon Mitchell at 5880 Memory Road Zanesville, Ohio 43701-9553 within 30 days, per ORC 1509:13(B)(7), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. Time of inspection: 8:55 AM. Weather: 61 degrees F, Sunny

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1267684752 US-OH-107181 2010-02-22 Well operation causing pollution and contamination
1267684752 US-OH-107182 2010-02-22 Well insufficiently equipped to prevent escape of oil and gas
1267684752 US-OH-107183 2010-02-22 Failure to legibly identify well
1357910173 US-OH-110357 2013-01-11 Statement of annual production not filed

For data sources see[8]