34-067-20682

Well Details

Well ID: 34-067-20682
Loading map...
Country: United States
State: Ohio
County: Harrison
Municipality: Monroe Township
Operator Name: ATLAS NOBLE LLC
Well Pad ID:
Farm/Lease Name: HUSS
License Status: Final Restoration
License Date: 2016-10-18
Spud Date: 1984-10-10
Spud Drilling Contractor: CHM DRLG
Final Drill Date: 1984-10-17
Well Total Depth: 5679.00 ft
Configuration: Vertical
Latitude: 40.370000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-09-04 43 RESOURCE AMERICA INC GeoDate 9/4/84
Oil and Gas 1984-09-04 Issued Date 9/4/84 Expired Date 3/3/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05679 Proposed Drill Depth 05679
Original Spud 1984-10-10
Completed 1984-10-17
Reached Total Depth 1984-10-17
Completion Report Received 1984-12-13
Change of Owner 2004-03-12 Operator changed from 43, RESOURCE AMERICA INC to 6867, ATLAS AMERICA INC
Change of Owner 2011-01-27 Operator changed from 6867, ATLAS AMERICA LLC to 6866, ATLAS NOBLE LLC
Change of Owner 2011-02-08 Operator changed from 6867, ATLAS AMERICA LLC to 6866, ATLAS NOBLE LLC
Plugged/Abandoned 2016-10-13
APP 2016-10-18 Proposed Formations:CLINTON, Issued Date:10/18/2016, Expired Date:10/18/2018 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-02-15
Construction Permit Expires 2018-10-18

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5441 5558 0
5441 5558 0
2006-09-11 5450 5546 57
5450 5546 57
5441 5558 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 138600 Gal 100000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 RESOURCE AMERICA INC 0.00 0.00 365
1987 RESOURCE AMERICA INC 4228.00 395.00 365
1988 RESOURCE AMERICA INC 3588.00 306.00 365
1989 RESOURCE AMERICA INC 3733.00 381.00 365
1990 RESOURCE AMERICA INC 3321.00 291.00 365
1993 RESOURCE AMERICA INC 1964.00 191.00 365
1994 RESOURCE AMERICA INC 1808.00 209.00 365
1995 RESOURCE AMERICA INC 1307.00 204.00 365
1996 RESOURCE AMERICA INC 1113.00 2070.00 365
1997 RESOURCE AMERICA INC 1326.00 299.00 365
1998 RESOURCE AMERICA INC 1325.00 127.00 365
2000 RESOURCE AMERICA INC 1011.00 106.00 365
2001 RESOURCE AMERICA INC 1253.00 128.00 365
2002 RESOURCE AMERICA INC 1443.00 232.00 365
2003 RESOURCE AMERICA INC 249.00 113.00 365
2004 CHEVRON APPALACHIA LLC 0.00 327.00 365
2005 CHEVRON APPALACHIA LLC 0.00 121.00 365
2006 CHEVRON APPALACHIA LLC 0.00 227.00 365
2007 CHEVRON APPALACHIA LLC 755.00 215.00 365
2008 CHEVRON APPALACHIA LLC 1399.00 185.00 366
2009 CHEVRON APPALACHIA LLC 1076.00 0.00 365
2010 ATLAS NOBLE LLC 942.00 0.00 365
2011 CHEVRON APPALACHIA LLC 400.00 0.00 365
2012 ATLAS NOBLE LLC 409.00 0.00 366
2013 ATLAS NOBLE LLC 392.00 0.00 365
2014 ATLAS NOBLE LLC 432.00 0.00 365
2015 ATLAS NOBLE LLC 342.00 0.00 335
2016 ATLAS NOBLE LLC 272.00 0.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 RESOURCE AMERICA INC Brine 0 365
1987 RESOURCE AMERICA INC Brine 0 365
1988 RESOURCE AMERICA INC Brine 0 365
1989 RESOURCE AMERICA INC Brine 0 365
1990 RESOURCE AMERICA INC Brine 135 365
1993 RESOURCE AMERICA INC Brine 0 365
1994 RESOURCE AMERICA INC Brine 0 365
1995 RESOURCE AMERICA INC Brine 0 365
1996 RESOURCE AMERICA INC Brine 0 365
1997 RESOURCE AMERICA INC Brine 0 365
1998 RESOURCE AMERICA INC Brine 0 365
2000 RESOURCE AMERICA INC Brine 0 365
2001 RESOURCE AMERICA INC Brine 0 365
2002 RESOURCE AMERICA INC Brine 95 365
2003 RESOURCE AMERICA INC Brine 0 365
2004 CHEVRON APPALACHIA LLC Brine 52 365
2005 CHEVRON APPALACHIA LLC Brine 65 365
2006 CHEVRON APPALACHIA LLC Brine 55 365
2007 CHEVRON APPALACHIA LLC Brine 37 365
2008 CHEVRON APPALACHIA LLC Brine 27 366
2009 CHEVRON APPALACHIA LLC Brine 10 365
2010 ATLAS NOBLE LLC Brine 0 365
2011 CHEVRON APPALACHIA LLC Brine 0 365
2012 ATLAS NOBLE LLC Brine 0 366
2013 ATLAS NOBLE LLC Brine 0 365
2014 ATLAS NOBLE LLC Brine 0 365
2015 ATLAS NOBLE LLC Brine 0 335
2016 ATLAS NOBLE LLC Brine 41 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1576871904 2016-10-24 0:00 FR No Violations 1.00
-332302552 2017-5-23 0:00: FR No Violations 1.00
-592905165 2015-12-29 0:00 PW No Violations 1.00
0056689613 2016-10-11 Plug / Plug Back No Violations I am on site today to witness the plugging of the well bore. Nicks Well Plugging Service is rigged up over the hole and will be preforming all service work. Specialized Safety Services is on site and will be providing safety assistance if needed. When I arrived on location Chuck Woods (an Atlas Noble Supervisor) informed me that on Columbus Day that NWP was able to pull all rods and was ready to set the bottom plug this morning. Prior to working on the well bore Specialized Safety Services evaluated the well for H2S and found alarming levels of the gas with upward readings of 4 percent concentration (40,000 ppm). After the test NWP then treated the well once again with H2S blocker. After treating the well NWP then went to pick up the tubing and discovered that the tubing was hung in the hole. In order to free the tubing NWP displaced 20 bbl. of fresh water on the backside of the tubing. After the fresh water was displaced NWP was then able to free the tubing and set the bottom plug from 5450- 5050 with 30 sacks of Class A cement and displacing with 19.5 barrels of fresh water. After setting the plug the well was shut in and left over night.
0332302552 2017-05-23 Final Restoration No Violations On the day of my inspection I found this well to be plugged. Area needs vegetation to pass final restoration. Spoke with Chris from Atlas and he is going to have a crew reseed it.
0349184707 2016-10-13 Plug / Plug Back No Violations I arrived on location today to witness the reminder of the plug job. As stated in my previous inspection Nicks Well Plugging Service is rigged up over the hole and will be preforming all service work. Specialized Safety Services is on site and will be providing safety assistance if needed. Upon arrival I witnessed NWP in the process of pulling out the production tubing. After pulling out the production tubing, I then witnessed NWP ripping the 4.5 inch diameter production casing at a depth of 1315 feet. The pipe was ripped at a higher depth due to the H2S factors of the well and safety concerns. After ripping the pipe NWP then pulled the 4.5 inch diameter production casing to a depth of 1200 feet and set a plug from 1200-980 feet, using 67 sacks of Class A cement and displacing with 15.6 barrels of fresh water. Then once that plug was displaced, NWP pulled the casing to a depth of 200 feet and circulated cement to surface. I then arrived later that day to check on the status of the plug and found that the surface plug had not dropped. I then witnessed Atlas Noble cutting the surface casing 3 feet below ground level and plating the well bore before filling the hole.
0592905165 2015-12-29 Production Wells No Violations On the day of my inspection I found this well is using an artificial lift pump-
1367648327 2016-10-07 Plug / Plug Back No Violations On the day of my inspection I met with Atlas Nobles Production Supervisor Chuck Woods to perform a site overview on the well, which is set to be plugged on the next work day. While on site Chuck informed me that he had been encountering some alarming H2S readings on the well bore. Chuck stated that he has treated the well once with 700 gallons of fresh water to 40 gallons of H2S blocker on the backside of the production casing and inside the production casing. He also informed me that plans to treat the well once again before preforming work on the well bore. I will be back on site after the weekend to witness the plugging of the well bore.
1476281614 2016-10-13 Plug / Plug Back No Violations Upon arrival on location I met with Inspector Joe Zollars and discussed the plugging that was completed and 10/12/16. Please refer to Joes plugging report.
1476355902 2016-10-12 Plug / Plug Back No Violations
1576871904 2016-10-24 Final Restoration No Violations I am on site today to check the status of the plug job that was just recently completed. With the conduction of my inspection I did not smell or notice any indication of H2S. The location has been graded but vegetation has yet to be established.
1645433017 2016-11-03 Final Restoration No Violations On the day of my inspection I witnessed that the lease road and well location had been restored. However vegetation was not established due to the season. With the inspection of the well bore I did not notice any signs of plug malfunction. I did not notice any indications of hydrogen sulfide while on site.
192330502 2020-4-2 0:00:0 FR No Violations 1.00
349184707 2016-10-13 0:00 PB No Violations 6.00
56689613 2016-10-11 0:00 PB No Violations 8.00

For data sources see[9]

References