Well Details

Well ID: 34-067-20483
Loading map...
Country: United States
State: Ohio
County: Harrison
Municipality: Franklin Township
Operator Name: ATLAS NOBLE LLC
Well Pad ID:
Farm/Lease Name: HUSS
License Status: Plugged and Abandoned
License Date: 2016-10-18
Spud Date: 1984-08-31
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1984-09-06
Well Total Depth: 5686.00 ft
Configuration: Vertical
Latitude: 40.360000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-09-02 43 RESOURCE AMERICA INC GeoDate 9/2/81
CO 1984-08-07 43 RESOURCE AMERICA INC GeoDate 8/7/84
Oil and Gas 1984-08-07 Issued Date 8/7/84 Expired Date 2/3/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05686 Proposed Drill Depth 05686
Original Spud 1984-08-31 R.I. 8-11-84

I&O CN 1988 12 247

Completed 1984-09-06 R.I. 8-11-84

I&O CN 1988 12 247

Reached Total Depth 1984-09-06 R.I. 8-11-84

I&O CN 1988 12 247

Completion Report Received 1984-12-31 R.I. 8-11-84

I&O CN 1988 12 247

Change of Owner 2004-03-12 Operator changed from 43, RESOURCE AMERICA INC to 6867, ATLAS AMERICA INC
Change of Owner 2011-01-27 Operator changed from 6867, ATLAS AMERICA LLC to 6866, ATLAS NOBLE LLC
Change of Owner 2011-02-08 Operator changed from 6867, ATLAS AMERICA LLC to 6866, ATLAS NOBLE LLC
Plugged/Abandoned 2016-10-06 R.I. 8-11-84

I&O CN 1988 12 247

APP 2016-10-18 Proposed Formations:CLINTON, Issued Date:10/18/2016, Expired Date:10/18/2018 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-06-22 R.I. 8-11-84

I&O CN 1988 12 247

Construction Permit Expires 2018-10-18 R.I. 8-11-84

I&O CN 1988 12 247

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5413 5500 0
5413 5500 0
2006-09-11 5440 5468 56
5440 5468 56
5413 5500 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 RESOURCE AMERICA INC 0.00 0.00 365
1985 RESOURCE AMERICA INC 2730.00 671.00 365
1987 RESOURCE AMERICA INC 3401.00 297.00 365
1988 RESOURCE AMERICA INC 2120.00 214.00 365
1989 RESOURCE AMERICA INC 1716.00 282.00 365
1990 RESOURCE AMERICA INC 1569.00 67.00 365
1991 RESOURCE AMERICA INC 1696.00 203.00 365
1993 RESOURCE AMERICA INC 1134.00 0.00 306
1994 RESOURCE AMERICA INC 145.00 96.00 50
1995 RESOURCE AMERICA INC 622.00 0.00 40
1996 RESOURCE AMERICA INC 648.00 970.00 132
1997 RESOURCE AMERICA INC 1126.00 191.00 365
1998 RESOURCE AMERICA INC 1095.00 102.00 365
1999 RESOURCE AMERICA INC 718.00 0.00 365
2000 RESOURCE AMERICA INC 649.00 104.00 365
2001 RESOURCE AMERICA INC 743.00 96.00 365
2002 RESOURCE AMERICA INC 949.00 0.00 365
2003 RESOURCE AMERICA INC 687.00 110.00 365
2004 CHEVRON APPALACHIA LLC 657.00 0.00 365
2005 RESOURCE AMERICA INC 776.00 0.00 365
2006 RESOURCE AMERICA INC 1025.00 107.00 365
2007 RESOURCE AMERICA INC 571.00 89.00 365
2008 RESOURCE AMERICA INC 1025.00 0.00 365
2009 RESOURCE AMERICA INC 793.00 89.00 365
2010 RESOURCE AMERICA INC 417.00 0.00 365
2011 RESOURCE AMERICA INC 601.00 43.00 365
2012 ATLAS NOBLE LLC 762.00 0.00 366
2013 ATLAS NOBLE LLC 532.00 0.00 365
2014 ATLAS NOBLE LLC 352.00 4.00 365
2015 ATLAS NOBLE LLC 182.00 0.00 335
2016 ATLAS NOBLE LLC 182.00 0.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 RESOURCE AMERICA INC Brine 0 365
1985 RESOURCE AMERICA INC Brine 705 365
1987 RESOURCE AMERICA INC Brine 0 365
1988 RESOURCE AMERICA INC Brine 0 365
1989 RESOURCE AMERICA INC Brine 0 365
1990 RESOURCE AMERICA INC Brine 52 365
1991 RESOURCE AMERICA INC Brine 0 365
1993 RESOURCE AMERICA INC Brine 0 306
1994 RESOURCE AMERICA INC Brine 0 50
1995 RESOURCE AMERICA INC Brine 0 40
1996 RESOURCE AMERICA INC Brine 0 132
1997 RESOURCE AMERICA INC Brine 0 365
1998 RESOURCE AMERICA INC Brine 167 365
1999 RESOURCE AMERICA INC Brine 0 365
2000 RESOURCE AMERICA INC Brine 0 365
2001 RESOURCE AMERICA INC Brine 0 365
2002 RESOURCE AMERICA INC Brine 171 365
2003 RESOURCE AMERICA INC Brine 0 365
2004 CHEVRON APPALACHIA LLC Brine 70 365
2005 RESOURCE AMERICA INC Brine 0 365
2006 RESOURCE AMERICA INC Brine 0 365
2007 RESOURCE AMERICA INC Brine 0 365
2008 RESOURCE AMERICA INC Brine 0 365
2009 RESOURCE AMERICA INC Brine 0 365
2010 RESOURCE AMERICA INC Brine 0 365
2011 RESOURCE AMERICA INC Brine 0 365
2012 ATLAS NOBLE LLC Brine 0 366
2013 ATLAS NOBLE LLC Brine 0 365
2014 ATLAS NOBLE LLC Brine 52 365
2015 ATLAS NOBLE LLC Brine 0 335
2016 ATLAS NOBLE LLC Brine 1 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1436817034 2016-9-2 0:00:0 PW No Violations 2.00
-252562394 2016-6-28 0:00: PW No Violations 2.00
-416889695 2016-10-3 0:00: PB No Violations 8.00
-585606368 2016-10-4 0:00: PB No Violations 11.00
-812809876 2016-7-8 0:00:0 PW No Violations 1.00
0049834720 2016-09-27 Production Wells No Violations I received a call from Chuck Woods (An Atlas Noble Supervisor) who informed me that he plans to have Nicks Well Plugging Services placed over the well bore by the end of the week or by the beginning of the next week at the latest. After receiving the call I went to the location to perform a site overview and discovered the well is still leaking H2S gas to atmosphere.
0252562394 2016-06-28 Production Wells No Violations I am checking this well for H2S leaks today and found that it has been identified wrong on the tank battery as permit #137 as the Huss # 1 While it is the Huss # 1 well it is the offset to the first well which has been plugged and restored. This well needs to have the correct identification placed at the well and due to the H2S status should be plugged or repaired. The well does have Hydrogen Sulfide Poison gas sign along with a wind sock at the well head. There is a 210 bbl. Production tank and a horizontal separator being used to produce the well which has a pump jack rods and 1 1/2 diameter tubing.
0310401827 2017-05-23 Production Wells No Violations On the day of my inspection I found this well to be plugged. The lease road is partially vegetated and there are remaining pipeline valves. Final restoration cannot be passed until these issues are fixed. Spoke to Chris from Atlas and he stated that the pipeline valves could be removed after the Huss 3 well is plugged, which they plan on plugging.
0416889695 2016-10-03 Plug / Plug Back No Violations I am on site today to witness the plugging of the well bore. On the day of my inspection I witnessed Nicks Well Plugging Services rigged up over the well bore. Specialized Safety Services is also on site with HS2 monitors station around the working perimeter and will be monitoring for H2S gas for the duration of the job. Prior to working on the well bore a safety meeting was held by Randy Tinker (A Specialized Safety Services employee) who informed everyone on location where the muster points where located and what to do in an emergency situation. Air packs where also stationed around the location, incase an emergency rescue needed to be preform. After the safety meeting I witnessed the well was tested for H2S readings. Readings on the backside on the production casing where calculated at 500 plus ppm H2S and 300 plus ppm inside the production casings. NWP then mixed one barrel of Hydrogen Sulfide Blocker to 30 barrels of fresh water and displaced it down the annular spaces. After the well was declared safe to work on, I then witnessed NWP pulling all rods out of the well bore and setting a 30 sack plug through 2.375 inch diameter tubing from 5450-5050 feet. NWP then displaced with 19.5 barrels of fresh water and pulled the tubing out of the well.
0585606368 2016-10-04 Plug / Plug Back No Violations I am on site today to continue witnessing the plugging of this well bore. As stated in my previous inspection Nicks Well Plugging Service will be preforming the service work and Specialized Safety Services will be preforming monitoring and providing safety services if needed. Sutton pump is on site this morning and is steaming the production tubing. Prior to working on the well I witnessed Specialized Safety Services packing up with an air pack and gathering H2S readings on the well bore. After evaluating the readings it was discovered there was 2,000 plus parts per million on the backside of the production casing and approximately 1800 ppm inside the production casing. After the readings NWP again treated the well with Hydrogen Sulfide blocker. While treating the well a meeting was held on the bases of plugging the well with limited exposer due to such high readings. Chuck Woods (an Atlas Noble Supervisor) and Mike Moreland (ODNR District Supervisor) agreed that a plug would be set in the lime using perforations and squeezing the cement. This was in an attempt to shut off the H2S producing zone. After theH2S was depleted NWP then ran the 2.375 inch diameter production tubing to a depth of 3900. Appalachian Well Surveys then ran wire line to a depth of 3949 and shot ten perforations in the 4.5 inch diameter production casing. After the perforations where set NWP then ran tubing to 3949 and set a 155 sack from a depth of 3949-3549. Once the plug was displaced NWP then squeezed with 3 barrels of fresh water and shut the well in for over the night.
0812809876 2016-07-08 Production Wells No Violations I am checking this well on a low pressure day due to the H2S gas present at this well. H2S has a higher percentage of leaks on low pressure days. I did not find any leaks which I could detect with my new H2S detector during this inspection.
0829737758 2016-10-06 Plug / Plug Back No Violations I am on site today to witness the final steps of plugging this well bore. As stated in my previous inspections Nicks Well Plugging Service will be preforming the service work and Specialized Safety Services will be preforming monitoring and providing safety services if needed. Prior to working on the well I witnessed Specialized Safety Services packing up with the air packs and taking H2S readings. After evaluating the readings from the well, it was discovered there was no H2S. After the reading NWP then pulled out the tubbing and tagged the plug that was set the previous day with the 4.5 inch diameter ripping tools. The plug was tagged at 3250. Once the plug was tagged we calculated that the H2S producing zone had been successfully plugged off and Specialized Safety Services then left the location. NWP then ripped the 4.5 inch diameter production casing at a depth of 1360 feet. After the casing was ripped NWP then pulled out the production casing to a depth of 1200 feet and set a plug from 1200-980 feet, utilizing 67 sacks of Class A cement and displacing with 15.6 barrels of fresh water. After setting the plug NWP then pulled the casing out to a depth of 200 feet and circulated cement to surface
1436817034 2016-09-02 Production Wells Violations Noted On the day of my inspection I witnessed the well is utilizing a pump-jack for means of production. The well bore consist of 8.625 inch diameter surface casing, 4.5 inch diameter production casing, 2.375 inch diameter production tubing and pump assembly components. A prime mover is in place on the unit. A leak and an odor could was noticed upon my arrival. After getting out of the truck and walking within approximately 20 feet of the well bore my H2S meter detected approximately 42 parts per million of Hydrogen Sulfide Gas. The leak of gas appeared to be coming from the 8.625 inch diameter surface casing. The well is located in a manor were it is proposing a threat to human health and safety. Production equipment for the well bore consists of a 210 barrel production tank, a 30 barrel brine tank and a horizontal separator with a 2 inch diameter meter run. The meter chart indicated the well was in producing order. All production equipment is placed in a dike that measures approximately 40*50 feet at an average height of 3 foot around the perimeter. After my inspection I called Chuck Woods and informed him of my findings. I then called my supervisor Mike Moreland who mandated that the well be plugged in 90 days.
1479147185 2016-10-05 Plug / Plug Back No Violations
1916886652 2016-10-07 Plug / Plug Back No Violations I arrived on location today to check the surface plug that was set the previous day. With the conduction of my inspection I discovered that the surface plug had not drop down hole. After seeing the plug had not dropped I then witnessed Atlas Noble cutting the surface pipe three feet below ground level, platting the well and reclaiming the location. I will be back at a later date to perform a final restoration check.
2117953935 2016-11-03 Final Restoration No Violations On the day of my inspection I witnessed that the lease road and well location had been restored. However vegetation was not established due to the season. With the inspection of the well bore I did not notice any signs of plug malfunction. I did not notice any indications of hydrogen sulfide while on site.
2134512379 2016-10-24 Final Restoration No Violations I am on site today to check the status of the plug job that was just recently completed. With the conduction of my inspection I did not smell or notice any indication of H2S. The location has been graded but vegetation has yet to be established.
310401827 2017-5-23 0:00: PW No Violations 1.00
49834720 2016-9-27 0:00: PW No Violations 2.00
829737758 2016-10-6 0:00: PB No Violations 8.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1436817034 US-OH-112741 2016-09-22 General Safety
1436817034 US-OH-112742 2016-09-22 Well insufficiently equipped to prevent escape of oil and gas
1436817034 US-OH-112743 2016-09-22 Well shall be plugged
1436817034 US-OH-112744 2016-09-22 Defective casing, leaking well

For data sources see[9]