X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24539

Well Details

Well ID: 34-059-24539
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001593
Farm/Lease Name: GINGERICH S LND GR
License Status: Producing
License Date: 2019-03-06
Spud Date: 2019-03-13
Spud Drilling Contractor:
Final Drill Date: 2019-05-16
Well Total Depth: 20588.00 ft
Configuration: Horizontal
Latitude: 40.080000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2018-11-30 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:11/30/2018, Expired Date:11/29/2020 12:00:00 PM, Drilling unit acres:60.407, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2019-03-06 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:3/6/2019, Expired Date:3/5/2021 12:00:00 PM, Drilling unit acres:707.99, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2019-04-13
Construction Permit Expires 2021-03-05

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
8010 20450 0
8010 20450 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1122898175 2020-5-26 0:00: PW No Violations 1.00
-1332408067 2019-3-25 0:00: DD No Violations 0.30
-1386390461 2019-3-18 0:00: DD No Violations 0.30
-284565082 2019-10-30 0:00 PW No Violations 0.30
-550457661 2019-3-29 0:00: DD No Violations 2.00
-625983704 2019-6-24 0:00: CT No Violations 2.00
-689976878 2019-5-7 0:00:0 DD No Violations 0.60
-759119157 2019-4-22 0:00: DD No Violations 1.50
-835874860 2019-6-11 0:00: CT No Violations 0.50
0016772735 2019-03-14 Casing String Witnessed No Violations Precision Rathole drilled a 30-inch diameter borehole to 100 feet in depth and installed 100 feet of 24-inch diameter conductor casing with welded joints. The conductor weighed 94.62 pounds per foot. During my inspection a pre-job safety meeting was held with all personnel on location and Petroset cementing rigged up on location and pumped 250 sacks of class A cement with 2 percent calcium chloride and displaced with 47 barrels of fresh water.
0550457661 2019-03-29 Drill / Deepen / Reopen No Violations The purpose of my inspection was a status check on drilling operations. During my inspection top-hole rig Falcon 38 was on location for Ascent Resources. Falcon 38 is a MD Cowan SuperSingle drilling rig with a rig floor at a height of 14.5-feet. During my inspection I witnessed the rig pick up their bottom hole assembly. I spoke with Ascent Company man Cassie Merreighn and he stated that they would send me updates as the drilling and run surface casing. The 13.375-inch diameter surface casing was located on the pipe racks. The proposed set depth for the surface casing was 1100-feet.
0689976878 2019-05-07 Drill / Deepen / Reopen No Violations The purpose of my inspection was a status check. During my inspection Akita drilling rig 803 was rigged up on location preparing to spud the curved section of the well bore.
0759119157 2019-04-22 Drill / Deepen / Reopen No Violations During my inspection Falcon 38 was running 9.625-inch diameter intermediate casing. The planned set depth was roughly 6750 feet and the cement job will be completed in two stages with a stage tool set roughly at 3570 feet. Schlumberger was rigging up on location. Following cementing operations Falcon 38 will rig down and head to the Ascent Ronald Pad.
1332408067 2019-03-25 Drill / Deepen / Reopen No Violations During my inspection Falcon drilling rig 38 was rigging up on location for Ascent resources. They plan to spud the 17.5-inch diameter surface borehole on 3/27/2019.
1386390461 2019-03-18 Drill / Deepen / Reopen No Violations Inspection today found the cement on the back side of the 24-inch diameter conductor level with the cellar floor. The mouse hole had been installed and grouted and the cellar was grouted into place. Rig mats were installed on location preparing for a top-hole rig to arrive.
16772735 2019-3-14 0:00: CS No Violations 1.50
2033601387 2020-9-2 0:00:0 PW No Violations 1.00
2103665385 2019-10-30 0:00 PW No Violations 0.30
352198665 2019-11-25 0:00 PL No Violations 0.30

For data sources see[4]