Well Details

Well ID: 34-059-24500
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001462
Farm/Lease Name: RABER W LND GR
License Status: Producing
License Date: 2017-04-19
Spud Date: 2017-05-01
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2017-09-16
Well Total Depth: 19410.00 ft
Configuration: Horizontal
Latitude: 40.080000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-04-19 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:4/19/2017, Expired Date:4/19/2019 12:00:00 PM, Drilling unit acres:685.362, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2017-09-16
Correction to Well 2017-12-22 UPDATE TAKE/TARGET/ACREAGE PER AS-DRILLED PLAT
Record Last Modified 2019-01-02
Construction Permit Expires 2019-04-19

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/03/2018 02/03/2018 7672 20,932,800.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
Olefins Proprietary 5 0.000107835 212
Ethylene glycol 107-21-1 60 0.0143686 27844
Glutaraldehyde 111-30-8 30 0.00637231 12349
Ethoxylated alcohols Proprietary 30 0.000269589 523
Guar gum 9000-30-0 100 0.00002993 58
Phosphoric acid 7664-38-2 0.1 0.00002124 42
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00106205 2059
Sodium polyacrylate 9003-04-7 1 0.000239476 465
Ethanol 64-17-5 1 0.00021241 412
Sodium persulfate 7775-27-1 100 0.00000052 1
Fatty acids, tall oil Proprietary 30 0.000269589 523
Propargyl alcohol 107-19-7 10 0.00008986 175
Sodium sulfate 7757-82-6 0.1 0.00000000 1
Hydrochloric acid 7647-01-0 7.5 0.02135 41378.9
Hydrotreated light petroleum distillate 64742-47-8 30 0.0171315 33198
Inorganic salt Proprietary 30 0.0171315 33198
Crystalline silica, quartz 14808-60-7 100 9.62196 18,645,300.0
Acrylic acid 79-10-7 0.01 0.00000239 5
Citric acid 77-92-9 60 0.00375503 7277
Telmer Proprietary 10 0.00239476 4641
Acrylamide acrylate copolymer Proprietary 30 0.0171315 33198
Modified thiourea polymer Proprietary 30 0.000269589 523
Methanol 67-56-1 60 0.000568914 1103
WG-36 GELLING AGENT Halliburton Gelling Agent Listed Below Listed Below 0 0 0
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
SCALECHEK LP-70 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
FE-2A Halliburton Additive Listed Below Listed Below 0 0 0
SP BREAKER Halliburton Breaker Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.354732 687398
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 89.9838 174,369,000.0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0
0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 759617 157147 272
2019 ASCENT RESOURCES UTICA LLC 182688 25999 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 22941 272
2019 ASCENT RESOURCES UTICA LLC Brine 4926 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1551845136 2018-9-12 0:00: PW No Violations 0.20
-1976967988 2018-5-17 0:00: PW No Violations 0.20
-519231818 2017-9-8 0:00:0 DD No Violations 1.00
0519231818 2017-09-08 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #584 had just landed their curve 8210 feet and was drilling ahead in the lateral with an 8.75 inch diameter on 12.5 pound per gallon mud. Patterson UTI Drilling Rig #584 will drill to approximately to 8410 feet, trip out and pickup an 8.5 inch Schlumberger Orbit tool and trip back in. Patterson UTI Drilling Rig #584 will continue drilling to a planned total depth of 19435 feet. I completed walk around with Ascent Consultant Alan Rice.
1048662132 2019-02-07 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges were present on all casing strings. The 13.375-inch diameter surface casing had 70 pounds per square inch and the 9.625-inch diameter intermediate had 355 pounds per square inch. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor. The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry. Ascent well tender was on location along with two Wise tanker trucks that were loading produce fluids from the tank battery.
1080269244 2017-05-11 Drill / Deepen / Reopen No Violations On the day inspection I witnessed that Falcon Drilling Rig #26 was moving and rigging up. I met with Ascent Consultant Raymond Sheperd and reviewed upcoming drill schedule for the pad.
1146234151 2018-07-06 Preliminary Restoration No Violations The purpose of my inspection was a status check on a preliminary restoration. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. The production equipment consisted of nine 400 barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor. The area effected by the pad construction has been restored with vegetation coverage. The lease road and well pad consisted of a gravel surface with no erosion issues. The location has met preliminary restoration requirements written within 1509.072 (A). The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry.
1460819265 2017-08-31 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #584 had drilled out the 13.375 inch diameter float equipment, drilled 10 feet of new wellbore to 1236 feet and successfully completed a Formation Integrity Test (FIT). I met with Ascent Drilling Superintendent Richard Thompson and Ascent Consultant Alan Rice and inspected the southeast sump revealing no sheen at this time. Ascent will continue to pump out the sump until results are satisfactory.
1493750066 2017-05-02 Casing String Witnessed No Violations On the day inspection I witnessed that Precision Rathole had drilled a 36 inch diameter hole to the depth of 100 feet, hitting water at 40 feet and ran 100 feet of 30 inch 118.65 pounds per foot conductor pipe. O-Tex Pumping LLC was onsite and pumped 2 barrels of fresh water, performed a 150 pounds per square inch pressure test, gained circulation with 2 barrels of fresh water and cemented pipe with 330 sacks Class H cement with 1.5% Calcium Chloride, .2% X--flake weighing 15.6 pounds per gallon and a yield of 1.2 cubic foot per sack. Cement was weight was verified with pressurized mud scales and displaced to 90 feet with 74.8 barrels of fresh water with good cement returns of 25 barrels to surface. Mix water was tested revealing chlorides of 54 parts per million, pH 7 and 59 degrees.
1494720175 2017-05-13 Casing String Witnessed No Violations On the day of my inspection I witnessed that Falcon Drilling Rig #26 had drilled a 17.5 inch diameter hole to the depth of 1225 feet and Wyoming casing crew ran 1218 feet of 13.375 inch 61 pounds per foot J-55 casing 4.7 feet above KB. Falcon Drilling Rig #23 washed down the last 4 joints of casing. O-Tex Pumping LLC was on site and gained circulation with 5 barrels of fresh water, 35 barrels of gel, 10 barrels of fresh water and cemented casing with 1350 sacks of Class H cement with 1.5% Calcium Chloride, .2% X--flake weighing 15.6 pounds per gallon and a yield of 1.19 cubic foot per sack. Cement weight was verified by pressurized mud scales at 15.6 pounds per gallon with the truck densometer off; cement was run at 16.7 pounds per gallon on the truck. Cement was displaced with 168 barrels of fresh water. Had good cement returns of 68 barrels, plug was landed at 540 pounds per square inch, pressured to 1100 pounds per square inch for 5 minutes and the floats held with1 barrel back Mix water was tested revealing chlorides of 39 parts per million, pH 7 and 55 degrees.
1551845136 2018-09-12 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges were present on all casing strings. The 9.625-inch diameter intermediate casing had 1300 pounds per square inch and the 13.375-inch surface casing had 25 pounds per square inch. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and two combustors. The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry.
1730280015 2017-10-16 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Allied Horizontal Wireline Services (AHWS) had just completed a gauge run on the 5.5 inch diameter casing. The tubing wellhead was being installed and upon completion AHWS will run a bond log on the casing. Location preparation is continuing for upcoming frac.
1976967988 2018-05-17 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. The wells on the pad are in the process of flowing back. The production equipment consisted of nine barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor.
200758530 2020-5-26 0:00: PW No Violations 1.00