If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-23692 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.84,"lon":-81.6,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Spencer Township | |
Operator Name: GREEN GAS CO | |
Well Pad ID: | |
Farm/Lease Name: BRIER ANDY & HELEN | |
License Status: Producing | |
License Date: 1986-08-13 | |
Spud Date: 1986-08-24 | |
Spud Drilling Contractor: MIDCO | |
Final Drill Date: 1986-08-31 | |
Well Total Depth: 5402.00 ft | |
Configuration: Vertical | |
Latitude: 39.840000 | |
Longitude: -81.600000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1986-08-13 | Issued Date 8/13/86 Expired Date 8/13/87 Acres 0000000 Tool Type RTAF Proposed Formation Proposed Depth 05402 Proposed Drill Depth 05402 |
Original Spud | 1986-08-24 | |
Completed | 1986-08-31 | |
Reached Total Depth | 1986-08-31 | |
CO | 1986-09-15 | 201 GREEN GAS CO GeoDate 8/13/86 |
Completion Report Received | 1986-09-19 | |
Construction Permit Expires | 1987-08-13 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5255 | 5286 | 24 |
5255 | 5286 | 24 | |
5255 | 5286 | 24 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 71500 Gal | 25500 | FRAC: H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | GREEN GAS CO | 1281.00 | 0.00 | 365 |
1987 | GREEN GAS CO | 18986.00 | 97.00 | 365 |
1988 | GREEN GAS CO | 13707.00 | 0.00 | 365 |
1989 | GREEN GAS CO | 9489.00 | 47.00 | 365 |
1990 | GREEN GAS CO | 5428.00 | 0.00 | 365 |
1991 | GREEN GAS CO | 9755.00 | 0.00 | 365 |
1992 | GREEN GAS CO | 9880.00 | 0.00 | 365 |
1993 | GREEN GAS CO | 8912.00 | 0.00 | 365 |
1995 | GREEN GAS CO | 6729.00 | 0.00 | 365 |
1997 | GREEN GAS CO | 5420.00 | 22.00 | 365 |
1998 | GREEN GAS CO | 4562.00 | 0.00 | 365 |
1999 | GREEN GAS CO | 4022.00 | 0.00 | 365 |
2000 | GREEN GAS CO | 3663.00 | 0.00 | 365 |
2001 | GREEN GAS CO | 3270.00 | 0.00 | 365 |
2002 | GREEN GAS CO | 3126.00 | 0.00 | 365 |
2003 | GREEN GAS CO | 575.00 | 0.00 | 365 |
2004 | GREEN GAS CO | 2477.00 | 0.00 | 365 |
2005 | GREEN GAS CO | 2355.00 | 0.00 | 365 |
2006 | GREEN GAS CO | 1676.00 | 0.00 | 365 |
2007 | GREEN GAS CO | 1990.00 | 0.00 | 365 |
2008 | GREEN GAS CO | 681.00 | 0.00 | 365 |
2009 | GREEN GAS CO | 1203.00 | 0.00 | 365 |
2010 | GREEN GAS CO | 676.00 | 0.00 | 365 |
2011 | GREEN GAS CO | 745.00 | 0.00 | 0 |
2012 | GREEN GAS CO | 911.00 | 30.00 | 366 |
2013 | GREEN GAS CO | 1196.00 | 0.00 | 365 |
2014 | GREEN GAS CO | 1054.00 | 0.00 | 365 |
2015 | GREEN GAS CO | 539.00 | 0.00 | 365 |
2016 | GREEN GAS CO | 516.00 | 0.00 | 365 |
2017 | GREEN GAS CO | 807.00 | 0.00 | 365 |
2018 | GREEN GAS CO | 639.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | GREEN GAS CO | Brine | 540 | 365 |
1987 | GREEN GAS CO | Brine | 0 | 365 |
1988 | GREEN GAS CO | Brine | 0 | 365 |
1989 | GREEN GAS CO | Brine | 0 | 365 |
1990 | GREEN GAS CO | Brine | 130 | 365 |
1991 | GREEN GAS CO | Brine | 100 | 365 |
1992 | GREEN GAS CO | Brine | 60 | 365 |
1993 | GREEN GAS CO | Brine | 0 | 365 |
1995 | GREEN GAS CO | Brine | 30 | 365 |
1997 | GREEN GAS CO | Brine | 35 | 365 |
1998 | GREEN GAS CO | Brine | 0 | 365 |
1999 | GREEN GAS CO | Brine | 24 | 365 |
2000 | GREEN GAS CO | Brine | 50 | 365 |
2001 | GREEN GAS CO | Brine | 0 | 365 |
2002 | GREEN GAS CO | Brine | 0 | 365 |
2003 | GREEN GAS CO | Brine | 0 | 365 |
2004 | GREEN GAS CO | Brine | 72 | 365 |
2005 | GREEN GAS CO | Brine | 0 | 365 |
2006 | GREEN GAS CO | Brine | 0 | 365 |
2007 | GREEN GAS CO | Brine | 0 | 365 |
2008 | GREEN GAS CO | Brine | 0 | 365 |
2009 | GREEN GAS CO | Brine | 0 | 365 |
2010 | GREEN GAS CO | Brine | 0 | 365 |
2011 | GREEN GAS CO | Brine | 0 | |
2012 | GREEN GAS CO | Brine | 0 | 366 |
2013 | GREEN GAS CO | Brine | 0 | 365 |
2014 | GREEN GAS CO | Brine | 0 | 365 |
2015 | GREEN GAS CO | Brine | 0 | 365 |
2016 | GREEN GAS CO | Brine | 0 | 365 |
2017 | GREEN GAS CO | Brine | 0 | 365 |
2018 | GREEN GAS CO | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-583908337 | 2005-10-3 0:00: | PW | No Violations | |
-954476647 | 2015-7-8 0:00:0 | PW | No Violations | 1.50 |
0000020378 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 1/7/92 INSPECTOR MIKE PHELPS DATE 01/0719/92 DATA FROM OLD VAX INFO | |
0479111435 | 2015-07-17 | Production Wells | No Violations | On the day of my inspection following up on NOV-2003019788, I witnessed that the tank has been replaced with the dump line being installed the contamination within the dike has been remediated along with proper identification being present. NOV -2003019788 has been resolved. |
0573112736 | 2008-12-10 | Production Wells | No Violations | PRODUCING WELL |
0583908337 | 2005-10-03 | Production Wells | No Violations | STATUS CHECK |
0954476647 | 2015-07-08 | Production Wells | No Violations | On the day of my inspection accompanied by Southeast Regional Supervisor Brent Bear following up on NOV-2003019788, I witnessed the well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, a plunger lift system with valves open on the tubing and 1 of 2 open on the casing supplying the motor valve. The production equipment included a 100bbl tank, a horizontal separator, a drip, a compressor unit, a 2 inch sales meter with a .5 inch orifice and a chart recorder. No action has been taken to address the 100bbl tank leaking, the contamination around tank or the identification of well. I placed call to Green Gas and advised them that the NOV needed addressed. |
1435837552 | 2015-07-02 | Production Wells | No Violations | On the day of my inspection I witnessed the well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, a plunger lift system with valves open on the tubing and 1 of 2 open on the casing supplying the motor valve. The production equipment included a 100bbl tank, a horizontal separator, a drip, a compressor unit, a 2 inch sales meter with a .5 inch orifice and a chart recorder. No action has been taken to address the contamination around 100bbl tank or the identification of well. I met with Green Gas field hand Junior Watson who was filling in for the well tender and I stated that the issues needed addressed and he stated he would let the office know. |
1509450978 | 2008-03-25 | Production Wells | No Violations | PRODUCING WELL |
2003019788 | 2015-06-16 | Production Wells | Violations Noted | On the day of my inspection I witnessed the well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, a plunger lift system with valves open on the tubing and 1 of 2 open on the casing supplying the motor valve. The production equipment included a 100bbl tank, a horizontal separator, a drip, a compressor unit, a 2 inch sales meter with a .5 inch orifice and a chart recorder. Identification was present but not legible, production records were current at the time of inspection and the 100bbl tank was defective with contamination present around the base. Owner/operator shall remove and replace tank, remove contamination and replace with clean fill. Owner/Operator shall properly identify well in accordance with OAC 1501:9-9-05 (A) 10. |
20378 | PL | No Violations | ||
479111435 | 2015-7-17 0:00: | PW | No Violations | 1.20 |
573112736 | 2008-12-10 0:00 | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
2003019788 | US-OH-120330 | 2015-07-22 | Well operation causing pollution and contamination | |
2003019788 | US-OH-120331 | 2015-07-22 | Failure to legibly identify well | |
2003019788 | US-OH-120332 | 2015-07-22 | No SPCC dike/or failure to keep dike free of water or oil |
For data sources see[9]