If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-22651 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.94,"lon":-81.44,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Richland Township | |
Operator Name: GENESIS RESOURCES LLC | |
Well Pad ID: | |
Farm/Lease Name: LASKO GEORGD & MARY JOANNE | |
License Status: Producing | |
License Date: 1979-11-19 | |
Spud Date: 1979-12-11 | |
Spud Drilling Contractor: | |
Final Drill Date: 1979-12-18 | |
Well Total Depth: 5789.00 ft | |
Configuration: Vertical | |
Latitude: 39.940000 | |
Longitude: -81.440000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1979-11-19 | 264 CONSOLIDATED RES OF AMER GeoDate 11/19/79 |
Original Spud | 1979-12-11 | 70.31=ACRES IP. A.F. |
Completed | 1979-12-18 | 70.31=ACRES IP. A.F. |
Reached Total Depth | 1979-12-18 | 70.31=ACRES IP. A.F. |
Change of Owner | 2003-03-20 | Operator changed from 4884, EASTERN STATES OIL & GAS INC to 5352, ARTEX OIL COMPANY |
Change of Owner | 2017-05-17 | Operator changed from 5352, ARTEX OIL COMPANY to 9239, GEORGETOWN OIL CO LLC |
Record Last Modified | 2019-06-04 | 70.31=ACRES IP. A.F. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5600 | 5633 | 12 |
2006-09-11 | 5680 | 5682 | 0 |
5600 | 5633 | 12 | |
5600 | 5633 | 12 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1190 Bbl | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | CONSOLIDATED RES OF AMER | 578.00 | 0.00 | 365 |
1986 | CONSOLIDATED RES OF AMER | 1421.00 | 0.00 | 365 |
1987 | CONSOLIDATED RES OF AMER | 1537.00 | 0.00 | 365 |
1988 | CONSOLIDATED RES OF AMER | 3196.00 | 0.00 | 365 |
1989 | CONSOLIDATED RES OF AMER | 1821.00 | 0.00 | 180 |
1990 | CONSOLIDATED RES OF AMER | 6371.00 | 0.00 | 365 |
1991 | CONSOLIDATED RES OF AMER | 6161.00 | 0.00 | 365 |
1995 | CONSOLIDATED RES OF AMER | 2104.00 | 0.00 | 365 |
1996 | CONSOLIDATED RES OF AMER | 1972.00 | 0.00 | 365 |
1997 | EASTERN STATES OIL & GAS INC | 1368.00 | 0.00 | 365 |
1998 | EASTERN STATES OIL & GAS INC | 1848.00 | 0.00 | 365 |
1999 | EASTERN STATES OIL & GAS INC | 314.00 | 0.00 | 365 |
2000 | EASTERN STATES OIL & GAS INC | 69.00 | 0.00 | 365 |
2001 | EASTERN STATES OIL & GAS INC | 0.00 | 0.00 | 365 |
2002 | EASTERN STATES OIL & GAS INC | 0.00 | 0.00 | 365 |
2003 | ARTEX OIL COMPANY | 798.00 | 0.00 | 365 |
2004 | ARTEX OIL COMPANY | 637.00 | 0.00 | 365 |
2005 | ARTEX OIL COMPANY | 608.00 | 0.00 | 365 |
2006 | ARTEX OIL COMPANY | 192.00 | 0.00 | 365 |
2007 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2008 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2009 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2010 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2011 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2012 | ARTEX OIL COMPANY | 0.00 | 0.00 | 366 |
2013 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2015 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2016 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2017 | ARTEX OIL COMPANY | 0.00 | 0.00 | 365 |
2018 | GEORGETOWN OIL CO LLC | 0.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1325641928 | 2007-10-9 0:00: | PW | No Violations | |
-1332583237 | 2019-4-11 0:00: | PW | No Violations | 0.10 |
-1473021768 | 2020-6-3 0:00:0 | PW | No Violations | 1.00 |
-1635688215 | 2020-3-17 0:00: | PW | No Violations | 1.00 |
-1863608862 | 2019-4-11 0:00: | PW | No Violations | 0.20 |
-194123184 | 2019-7-19 0:00: | PW | No Violations | 1.00 |
-759101013 | 2006-1-9 0:00:0 | PW | No Violations | |
0174847600 | 2008-01-02 | Production Wells | No Violations | STATUS CHECK |
0568954274 | 2017-03-08 | Production Wells | No Violations | On the day of my inspection I witnessed the well was equipped with 4.5 inch diameter casing, 2.875 inch diameter tubing, 1.5 inch diameter tubing, a plunger lift system and domestic gas service with valves closed on the 1.5 inch diameter tubing and 1 of 2 open on the 2.875 inch diameter tubing supplying the domestic gas service. The production equipment included a 100 barrel tank, a horizontal separator, a 2 inch salesmeter with .75 inch orifice and a chart recorder with no chart present all within an earthen dike. Identification was present and production records were current. |
0630814366 | 2019-02-19 | Production Wells | No Violations | The purpose of my inspection was a follow up on complaint number 6068 and compliance notice 1549473424. Inspection found no change in status since the inspection on 2/6/2019. Production valves appeared to be in the closed position and the domestic service was not in use. While utilizing the Ventis Pro 4 Gas Detector zero gas readings were recorded. On 2/8/2019 I spoke with Georgetown Oil and the company stated that they plan to get the well in production as soon as issues with the landowner are resolved. |
0759101013 | 2006-01-09 | Production Wells | No Violations | STATUS CHECK |
1021891218 | 2019-04-11 | Production Wells | No Violations | The purpose of my inspection was a follow up on complaint number 6068 and compliance notice 1549473424. Inspection found no change in status since the inspection on 2/19/2019. Production valves appeared to be in the closed position and the domestic service was not in use. While utilizing the Ventis Pro 4 Gas Detector zero gas readings were recorded. On 2/8/2019 I spoke with Georgetown Oil and the company stated that they plan to get the well in production as soon as issues with the landowner are resolved |
1258579917 | 2009-11-16 | Production Wells | No Violations | Inspection revealed that well is equipped with 8surface casing and 4.5 production casing and 2.875 tubing and 1.5 tubing and 1-100 bbl tank and seperator located within dike area,well is being used for domestic purposes only at this time. |
1289i25753 | 2001-05-03 | Production Wells | No Violations | STATUS CHECK, WELL USED FOR DOMESTIC GAS. |
1289i25753839 | 2001-5-3 0:00:0 | PW | No Violations | |
1325641928 | 2007-10-09 | Production Wells | No Violations | STATUS CHECK |
1526435236 | 2012-12-28 | Production Wells | No Violations | On the day of my inspection I found the divisions production records current for the year of 2011, the valve on the production line was open, there is (1) one hundred barrel production tank with the I.D./ separator/ drip/ chart setting inside a containment dike. |
1549473424 | 2019-02-06 | Production Wells | Violations Noted | The purpose of my inspection was a follow up on complaint number 6068. The complainant stated that the well had been abandon for more than a decade. Inspection found 4.5-inch diameter production casing with a casing head, 2.875-inch diameter intermediate casing with a tubing head, 1.5-inch diameter production tubing, and a plunger lift system. Production valves appeared to be in the closed position. The 2.875-inch intermediate casing had a domestic gas service attached with a Little Joe Regulator and an open valve. I contacted the landowner Tim Lasko and asked him if the well was providing domestic gas for any local residences and Mr. Lasko stated that the domestic line was shut off at his house and it was not providing domestic gas. The production equipment consisted of one 100-barrel tank, one horizontal separator, and a sales meter. The sales meter had a 2-inch diameter sales line, a .75-inch orifice plate, and a chart recorder with a chart that was not legible. The production reports that have been submitted to ODNR report records of zero production from years 2007 to 2017. I left a voicemail with Georgetown Oil Company with call back information. Georgetown Oil Company shall submit a written plugging schedule to Austin Gutridge at 5880 Memory Rd., Zanesville Ohio 43701 within 30 days, per ORC 1509:13(B)(7) and plug the well within 180 days. Georgetown Oil Company will be notified if the plugging schedule is approved or denied. |
1602263057 | 2020-10-6 0:00: | PW | No Violations | 1.00 |
1658923017 | 2008-04-28 | Production Wells | No Violations | ID REPOSTED. |
174847600 | 2008-1-2 0:00:0 | PW | No Violations | |
1984531785 | 2020-1-22 0:00: | PW | No Violations | 0.50 |
568954274 | 2017-3-8 0:00:0 | PW | No Violations | 1.00 |
630814366 | 2019-2-19 0:00: | PW | No Violations | 0.70 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1549473424 | US-OH-115041 | 2019-02-15 | Well shall be plugged |
For data sources see[9]