Well Details

Well ID: 34-059-21837
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: JENKINS-LEPAGE ETAL UNIT
License Status: Producing
License Date: 1974-10-11
Spud Date: 1974-11-18
Spud Drilling Contractor:
Final Drill Date: 1974-11-30
Well Total Depth: 5171.00 ft
Configuration: Vertical
Latitude: 39.890000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1974-10-11 182 BELDEN & BLAKE CO GeoDate 10/11/74
Original Spud 1974-11-18
Completed 1974-11-30
Reached Total Depth 1974-11-30
CO 1993-01-28 4381 PELICAN PRODUCING INC GeoDate 10/11/74
CO 1995-11-24 1217 HARRISON ENERGY GeoDate 10/11/74
CO 1996-04-10 952 G-R CONTRACTING INC GeoDate 10/11/74
Change of Owner 2013-05-20 Operator changed from 952, G-R CONTRACTING INC to 1333, BIG SKY ENERGY INC
Record Last Modified 2019-06-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5026 5054 2
5026 5054 2
5026 5054 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 92000 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 ENTERPRISE ENERGY CORP 3800.00 457.00 0
1985 OXFORD OIL 2927.00 482.00 365
1986 OXFORD OIL 2464.00 358.00 365
1987 BELDEN & BLAKE CORPORATION 2282.00 351.00 365
1988 OXFORD OIL 1897.00 305.00 365
1990 BELDEN & BLAKE CORPORATION 2215.00 367.00 302
1991 BELDEN & BLAKE CORPORATION 2128.00 293.00 365
1992 BELDEN & BLAKE CORPORATION 1640.00 290.00 269
1993 BELDEN & BLAKE CORPORATION 67.00 0.00 366
1994 PELICAN PRODUCING INC 1891.00 483.00 365
1995 PELICAN PRODUCING INC 1304.00 158.00 310
1996 G-R CONTRACTING INC 1356.00 348.00 365
1997 G-R CONTRACTING INC 1045.00 279.00 365
1998 G-R CONTRACTING INC 1204.00 195.00 365
2000 G-R CONTRACTING INC 685.00 454.00 365
2001 G-R CONTRACTING INC 865.00 197.00 365
2002 G-R CONTRACTING INC 421.00 90.00 365
2003 G-R CONTRACTING INC 451.00 505.00 365
2004 G-R CONTRACTING INC 292.00 491.00 365
2005 G-R CONTRACTING INC 338.00 489.00 365
2006 G-R CONTRACTING INC 940.00 437.00 365
2007 G-R CONTRACTING INC 374.00 458.00 365
2008 G-R CONTRACTING INC 260.00 326.00 365
2009 G-R CONTRACTING INC 307.00 310.00 365
2010 G-R CONTRACTING INC 317.00 343.00 365
2011 G-R CONTRACTING INC 200.00 95.00 365
2012 G-R CONTRACTING INC 114.00 0.00 366
2013 BIG SKY ENERGY INC 149.00 0.00 365
2014 BIG SKY ENERGY INC 8.00 0.00 365
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 ENTERPRISE ENERGY CORP Brine 170 0
1985 OXFORD OIL Brine 0 365
1986 OXFORD OIL Brine 0 365
1987 BELDEN & BLAKE CORPORATION Brine 157 365
1988 OXFORD OIL Brine 0 365
1990 BELDEN & BLAKE CORPORATION Brine 27 302
1991 BELDEN & BLAKE CORPORATION Brine 2 365
1992 BELDEN & BLAKE CORPORATION Brine 3 269
1993 BELDEN & BLAKE CORPORATION Brine 0 366
1994 PELICAN PRODUCING INC Brine 15 365
1995 PELICAN PRODUCING INC Brine 10 310
1996 G-R CONTRACTING INC Brine 0 365
1997 G-R CONTRACTING INC Brine 0 365
1998 G-R CONTRACTING INC Brine 0 365
2000 G-R CONTRACTING INC Brine 0 365
2001 G-R CONTRACTING INC Brine 0 365
2002 G-R CONTRACTING INC Brine 0 365
2003 G-R CONTRACTING INC Brine 0 365
2004 G-R CONTRACTING INC Brine 0 365
2005 G-R CONTRACTING INC Brine 0 365
2006 G-R CONTRACTING INC Brine 0 365
2007 G-R CONTRACTING INC Brine 0 365
2008 G-R CONTRACTING INC Brine 0 365
2009 G-R CONTRACTING INC Brine 0 365
2010 G-R CONTRACTING INC Brine 0 365
2011 G-R CONTRACTING INC Brine 0 365
2012 G-R CONTRACTING INC Brine 0 366
2013 G-R CONTRACTING INC Brine 0 120
2014 G-R CONTRACTING INC Brine 0 30
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1021016301 2015-11-30 0:00 PW No Violations 1.00
-1125015489 2009-2-26 0:00: PW No Violations
-1673034397 2016-4-14 0:00: PW No Violations 1.00
-1723565080 2003-9-18 0:00: PW No Violations
-1754784650 2020-3-31 0:00: PW No Violations 1.00
-357517569 2008-4-21 0:00: PB No Violations
-504211616 2004-4-27 0:00: PW No Violations
-555241790 2015-9-30 0:00: PW No Violations 1.50
-59076923 2017-2-27 0:00: PW No Violations 1.00
0059076923 2017-02-27 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 1/23/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

0348746107 2013-10-09 Production Wells No Violations On the day of my inspection I found no changer in the status of the well, I placed a phone call to Big Sky Energy to discuss the status of the well and my call went to voice mail, I left a message to return my call.
0357517569 2008-04-21 Plug / Plug Back No Violations G-R DRILLING MOVE ON WELL TO PLUG. STRONG INDICATIONS OF H2S.RIG UP OVER HOLE.
0408238574 2004-09-14 Production Wells No Violations STATUS CHECK, PUMPING UNIT, WELL IN PRODUCTION.
0427920597 2017-10-12 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 8/4/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

0462892900 2018-02-07 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 12/5/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch meter run with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

0480769322 2015-02-02 Production Wells No Violations On the day of my inspection following up on NOV-1377007275, I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with valves in the closed position and the flowline disconnected. Tubing and rods had been pulled from the well and were on location along with a disconnected pumping unit. Production equipment included a 210bbl tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike with identification was present. I placed call to Big Sky well tender Greg Henderson requesting an update on well and he stated that he would get with Bob Barr and get a plan.
0504211616 2004-04-27 Production Wells No Violations STATUS CHECK
0555241790 2015-09-30 Production Wells No Violations On the day of my inspection following up on NOV-1377007275 I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with valves in the closed position and the flowline disconnected. Tubing and rods had been pulled from the well and were on location along with a disconnected pumping unit. Production equipment included a 210bbl tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7. Identification was present with contamination still present inside the dike. The chart was changed on 8/6/15 showing the well is cycling which is the Jenkins LePage #7 34059216800000 but has the Jenkins LePage 6 and 7 written on the location on the chart. There was no change in the status of the said well since last inspection and field testing of water in the dike revealed <30ppm chlorides and a pH of 6.
0575758364 2017-06-13 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 3/30/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

0624046504 2018-10-23 Production Wells No Violations

--105, and compliance notice 1377007275. The well was equipped with 8.625-inch diameter casing with a casing head, 3.5-inch diameter production casing, and a 3.5 inch to 2 inche diameter swage nipple. All valves were in the closed position and there were no lines attached to the well. A disconnected pumping unit and a stack of tubing and rods were lying next to the well. The production equipment consisted of one 210-barrel tank, one vertical separator, one drip, and a chart meter. All production equipment was within an earthen dike. A dry paraffin and oil mixture remain within the dike.

0638085401 2015-04-30 Production Wells No Violations On the day of my inspection following up on NOV-1377007275 accompanied by ODNR Inspector Matt Fulk, I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with valves in the closed position and the flowline disconnected. Tubing and rods had been pulled from the well and were on location along with a disconnected pumping unit. Production equipment included a 210bbl tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7. Identification was present with contamination present inside the dike. The chart was changed on 4/21/15 showing the well is cycling which is the Jenkins LePage #7 34059216800000. There was no change in the status of the said well since last inspection and updated photographs were taken.
1021016301 2015-11-30 Production Wells No Violations On the day of my inspection following up on NOV-1377007275 I witnessed there was no change in the status of the well and it was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with valves in the closed position and the flowline disconnected. Tubing and rods had been pulled from the well and were on location along with a disconnected pumping unit. Production equipment included a 210bbl tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7. A 210bbl tank which was located inside the dike where contamination was present has been removed with the contamination still present.
1125015489 2009-02-26 Production Wells No Violations WELL IS IN PRODUCTION.
1153259568 2019-03-20 Production Wells No Violations

--105, and compliance notice 1377007275. The well was equipped with 8.625-inch diameter casing with a casing head, 3.5-inch diameter production casing, and a 3.5 inch to 2-inch diameter swage nipple. All valves were in the closed position and there were no lines attached to the well. A disconnected pumping unit and a stack of tubing and rods were lying next to the well. The production equipment consisted of one 210-barrel tank, one vertical separator, one drip, and a chart meter. All production equipment was within an earthen dike. A dry paraffin and oil mixture remain within the dike.

1182912531 2019-11-26 0:00 PW No Violations 0.30
1208896310 2008-04-22 Plug / Plug Back No Violations CO. TOOLS RUNNING 4898 1.5 BACK TO BOTTOM. TENTIVALLY TO SET 2 PLUGS THRU TUBING 4/23/2008.
1237665989 2016-03-18 Production Wells No Violations On the day of my inspection following up on NOV-1377007275 I witnessed there was no change in the status of the well since the last inspection. The well was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with valves in the closed position and the flowline disconnected. Production equipment included a 210bbl tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7. Contamination was still present inside dike where 210bbl tank was removed.
1340734792 2012-06-25 Production Wells No Violations On the day of my inspection I found four inch well casing with a (4x2) swedge with a ball valve that is half open and a rubber high pressure hose connecting the well to the production line, the land owner told me that G an R pulled the pumping unit off the well and left it on the location, they also pulled the tubing/ rods out of the well two years ago and left it on the location as well, the land owner said that no one has been back to the well for two years. G an R shut his house gas off at that time. I did my inspection of the well and the location and all the material is still on the well site.
1364512564 2013-03-27 Production Wells No Violations Inspected site along with county inspector to determine if well was capable of producing,adjacient landowner claims well is idle and company is back feeding gas line to make well appear to be producing, we had well tender unhook flow line from well and we then put pressure gauge on well head and it had 30# gas pressure on it and well is being used for domestic purposes also, told adjacent landowner that well is producing both domestic gas and is also selling a little gas commercially.
1377007275 2013-08-20 Production Wells Violations Noted On the day of my inspection I meet with the land owner Tom Henry, At the well site I witnessed four and a half inch production casing with a (4x2) swedge and valve standing from the ground, the valve on top of the (4x2) swedge was open, all production lines and sales lines were disconnected from the well, the pumping unit has been pulled away from the well but is still on location, the tubing and rods have been removed from the well and are on location, the previous well owner told me the casing parted down hole approximately three or more years ago. Production has been reported to The Division of Oil and Gas from the year of 1984 to 2012. There are (2) two hundred ten barrel production tanks/ separator/ drip and chart setting inside a containment dike, there is containment soil around the tanks, the I.D. is posted on one of the tanks. The requirements to meet the Division of Oil and Gas Standards will be to make the well capable of commercial production within thirty days or plugging is required within thirty days. Failure to comply may result in Forfeiture of Bond.
1484690341 2017-01-23 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well and it was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

1512480698 2017-12-05 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 10/12/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch meter run with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

1560334715 2017-03-30 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 2/27/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike. I met with land owner Tom Henry who stated that the well has been in its current state for over 5 years and that Big Sky is not allowed on his property.

1673034397 2016-04-14 Production Wells No Violations

--105 and NOV-1377007275, I witnessed the well was equipped with 8.625 inch casing and 3.5 inch casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210bbl tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7. Identification was present with contamination remaining inside the dike.

1723565080 2003-09-18 Production Wells No Violations SMALL OIL STAIN INSIDE DIKE.
1725162134 2013-03-04 Production Wells Violations Noted On the day of my inspection I meet with the land owner Tom Henry, At the well site I witnessed four and a half inch production casing with a (4x2) swedge and valve standing out of the ground, the valve was open. The pumping unit has been pulled away from the well but is still on location, the tubing and rods have been removed from the well and are on location, the land owner told me the casing parted down hole. The Divisions production records for the year of 2011 meet Divisions standards but no current records have been recorded for the year of 2012. There are (2) two hundred ten barrel production tanks/ separator/ drip chart setting inside a containment dike, there is a oil stain in between the two tanks, the I.D.is posted on the tank. The requirements to meet the Division of Oil and Gas standards will be to make the well capable of commercial production within thirty days or plugging is required within sixty days. Failure to comply may result in Forfeiture of Bond.
1725366450 2017-07-18 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 6/13/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

1771842679 2017-08-04 Production Wells No Violations

--105 and NOV-1377007275, I witnessed there was no change in the status of the well since the last inspection on 7/18/17. The well was equipped with 8.625 inch diameter casing and 3.5 inch diameter casing reduced to 2 inches with valves in the closed position and the flowline disconnected making the well incapable of production. Tubing and rods had been pulled from the well and were on location along with a disconnected OCS pumping unit. Production equipment included a 210 barrel tank, a vertical separator, a drip, a 2 inch sales meter with a .25 inch orifice and a chart recorder all within an earthen dike shared with 34059216800000 Jenkins LePage 7 and the chart was dated 4/12/16. Identification was present with contamination remaining inside the dike.

309666799 2020-7-23 0:00: PW No Violations 1.00
348746107 2013-10-9 0:00: PW No Violations
408238574 2004-9-14 0:00: PW No Violations
427920597 2017-10-12 0:00 PW No Violations 1.00
462892900 2018-2-7 0:00:0 PW No Violations 1.00
480769322 2015-2-2 0:00:0 PW No Violations 1.50
575758364 2017-6-13 0:00: PW No Violations 1.00
624046504 2018-10-23 0:00 PW No Violations 0.40
638085401 2015-4-30 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1377007275 US-OH-111174 2013-08-21 General Safety
1377007275 US-OH-111175 2013-08-21 No SPCC dike/or failure to keep dike free of water or oil
1377007275 US-OH-111176 2013-08-21 Well shall be plugged
1377007275 US-OH-111177 2013-08-21 Defective casing, leaking well
1377007275 US-OH-111178 2013-08-21 Statement of annual production not filed
1725162134 US-OH-117115 2013-04-10 General Safety
1725162134 US-OH-117116 2013-04-10 Well shall be plugged
1725162134 US-OH-117117 2013-04-10 Defective casing, leaking well
1725162134 US-OH-117118 2013-04-10 Statement of annual production not filed

For data sources see[9]

References