X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-21271

Well Details

Well ID: 34-059-21271
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Monroe Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: LOBB WM H
License Status: Producing
License Date: 1970-05-19
Spud Date: 1970-06-11
Spud Drilling Contractor:
Final Drill Date: 1970-06-19
Well Total Depth: 5264.00 ft
Configuration: Vertical
Latitude: 40.210000
Longitude: -81.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1970-05-19 1333 BARR ROBT/dba BIG SKY PET GeoDate 5/19/70
Original Spud 1970-06-11
Completed 1970-06-19
Reached Total Depth 1970-06-19
Construction Permit Expires 1971-05-19
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5154 5197 0
5154 5197 0
5154 5197 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1683 Bbl 45000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JAMES DRILLING CORP 1873.00 0.00 0
1985 JAMES DRILLING CORP 2734.00 0.00 0
1986 JAMES DRILLING CORP 1580.00 0.00 365
1987 JAMES DRILLING CORP 2975.00 0.00 365
1988 JAMES DRILLING CORP 2908.00 0.00 365
1989 JAMES DRILLING CORP 0.00 2273.00 365
1990 JAMES DRILLING CORP 1410.00 0.00 365
1993 BIG SKY ENERGY INC 5320.00 0.00 365
1995 BIG SKY ENERGY INC 4915.00 0.00 365
1996 BIG SKY ENERGY INC 4863.00 0.00 365
1998 BIG SKY ENERGY INC 286.00 0.00 365
2000 BIG SKY ENERGY INC 0.00 0.00 365
2001 BIG SKY ENERGY INC 213.00 0.00 365
2003 BIG SKY ENERGY INC 572.00 0.00 365
2004 BIG SKY ENERGY INC 66.00 0.00 365
2005 BIG SKY ENERGY INC 1039.00 0.00 365
2006 BIG SKY ENERGY INC 959.00 0.00 365
2007 BIG SKY ENERGY INC 891.00 0.00 365
2008 BIG SKY ENERGY INC 236.00 0.00 365
2009 BIG SKY ENERGY INC 68.00 0.00 365
2011 BIG SKY ENERGY INC 3.00 0.00 365
2012 BIG SKY ENERGY INC 473.00 0.00 366
2013 BIG SKY ENERGY INC 384.00 0.00 300
2014 BIG SKY ENERGY INC 936.00 0.00 300
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JAMES DRILLING CORP Brine 0 0
1985 JAMES DRILLING CORP Brine 0 0
1986 JAMES DRILLING CORP Brine 0 365
1987 JAMES DRILLING CORP Brine 0 365
1988 JAMES DRILLING CORP Brine 0 365
1989 JAMES DRILLING CORP Brine 0 365
1990 JAMES DRILLING CORP Brine 0 365
1993 BIG SKY ENERGY INC Brine 0 365
1995 BIG SKY ENERGY INC Brine 0 365
1996 BIG SKY ENERGY INC Brine 0 365
1998 BIG SKY ENERGY INC Brine 0 365
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 300
2014 BIG SKY ENERGY INC Brine 0 300
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1251395316 2018-2-6 0:00:0 PW No Violations 0.80
-1289939885 2003-4-7 0:00:0 PW No Violations
-1673101506 2014-12-2 0:00: PW No Violations 2.00
-1909720397 2013-8-27 0:00: PW No Violations
-197144318 2019-12-17 0:00 PW No Violations 1.20
-1995445811 2005-12-22 0:00 PW No Violations
-2063069904 2011-12-12 0:00 PW No Violations
-304229566 2011-12-12 0:00 PW No Violations
-317575660 2014-12-3 0:00: PW No Violations 1.50
-375111653 2007-8-1 0:00:0 PW No Violations
-41031632 2012-9-11 0:00: PW No Violations
-46021124 2015-4-28 0:00: PW No Violations 1.00
-464155377 2011-12-12 0:00 PW No Violations
-654994654 2016-5-18 0:00: PW No Violations 2.00
0041031632 2012-09-11 Production Wells No Violations Inspection revealed that owner has removed faulty tank from dike area but has failed to place well back into commercial production it is being used for domestic purposes only at this time.

Note : Relief valve on separator is leaking will contact well owner to have it replaced.

0046021124 2015-04-28 Production Wells No Violations

-132 and NOV-

0304229566 2011-12-12 Production Wells No Violations FOLLOW UP TO NOV # -2063069904 I received a complaint from the landowner of an idle well on the property and of a possible leaking tank within dike area. Upon inspecting the site I found the well is equipped with 8 surface casing , 4.5 production casing and a concoil catcher on top. It is being used for domestic purposes only and there has been no production reported on this well since 2009. There is no identification on either tank or wellhead. There is oil and other waste within dike area.

Plug, produce or apply for temporary inactive status. Cleanup/remediate and properly dispose of oil and other waste in containment area. If placed into production, proper identification must be posted and report production as required by law. Failure to comply may result in bond forfeiture.

0317575660 2014-12-03 Production Wells No Violations

-132 and NOV-

0375111653 2007-08-01 Production Wells No Violations STATUS CHECK.
0442442151 2016-09-13 Production Wells No Violations

--105 and Compliance Notice--2063069904. Identification was present and production records were current. No gas flowing through the master meter on Ash Road and the compressor unit in the off position.

0464155377 2011-12-12 Production Wells No Violations FOLLOW UP TO NOV # -2063069904 I received a complaint from the landowner of an idle well on the property and of a possible leaking tank within dike area. Upon inspecting the site I found the well is equipped with 8 surface casing , 4.5 production casing and a concoil catcher on top. It is being used for domestic purposes only and there has been no production reported on this well since 2009. There is no identification on either tank or wellhead. There is oil and other waste within dike area.

Plug, produce or apply for temporary inactive status. Cleanup/remediate and properly dispose of oil and other waste in containment area. If placed into production, proper identification must be posted and report production as required by law. Failure to comply may result in bond forfeiture.

0654994654 2016-05-18 Production Wells No Violations The purpose of my inspection today is a Civil Action Follow---10 5. As of 5/18/16 domestic gas has been shut off. During my inspection I witnessed Greg Henderson from Big Sky shut in the domestic gas line. All valves on the well are now in the closed position. Greg Henderson and I went to all homes that were receiving natural gas from this well to inform them that they will be without natural gas.
1090984311 2012-04-04 Production Wells No Violations Inspection revealed that owner has removed leaking tank from dike area but well still remains idle and owner has not replaced production tank at site.
1196759463 2006-12-07 Production Wells No Violations STATUS CHECK PRODUCING WELL
1251395316 2018-02-06 Production Wells No Violations

--105 and Compliance Notice-2063069904, I witnessed that the well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, a casing lift system reduced to a 2 inch flowline. Production equipment included a horizontal separator and domestic gas service with the valve on casing in the half open position. Identification was present and production records were current.

1274890555 2014-11-13 Production Wells No Violations

-132 and NOV-

1289939885 2003-04-07 Production Wells No Violations STATUS CHECK
1307651379 2016-05-04 Production Wells No Violations

--105 and Compliance Notice-

1402933694 2014-06-16 Production Wells No Violations

-132 and NOV-2063069904, I witnessed that the well was equipped with 8.625 inch casing, 4.5 inch casing reduced to a 2 inch flowline with the valve on casing in the closed position. The flowline was connected to a horizontal separator which had a domestic gas hookup with a 1 inch service line on the downstream side. No identification was present and no additional production equipment was on site.

1554065621 2016-04-17 Production Wells No Violations

--105 and Compliance Notice-

1554728920 2019-04-08 Production Wells No Violations

--105. During my inspection the well was equipped with 8.625-inch diameter surface casing with a casing head, 4.5-inch diameter production casing, and ConCoyle casing lift system. The casing valve was in the open position. The 2-inch diameter commercial production line was disconnected from the well. A domestic gas line was attached with a Little Joe separator and an open valve. The plastic domestic gas line had a slight gas leak. A new 1-inch diameter plastic gas line was on location but has not been installed. The production equipment consisted of one horizontal separator. The dump valve on the separator had a 1-foot by 1-foot area of oil residue on the ground below the dump valve. Identification was located on the horizontal separator and Big Sky Energy has submitted reports of zero production for the years 2016 and 2017. Accompanied by ODNR inspector Rick Brown during inspection.

1576797090 2019-12-17 0:00 PW No Violations 0.50
1576858371 2019-12-17 0:00 PW No Violations 1.30
1673101506 2014-12-02 Production Wells No Violations

-132 and NOV--2063069904 for said well.

1726540770 2017-08-03 Production Wells No Violations

--105 and Compliance Notice-2063069904, I witnessed that the well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, a casing lift system reduced to a 2 inch flowline. Production equipment included a horizontal separator and domestic gas service with the valve on casing in the half open position. Identification was present and production records were not current. No gas flowing through the master meter on Ash Road and the compressor unit in the off position. Dominion East Ohio had left a note in the chart box stating the station was shut-in on 12-6-16

1849392731 2016-03-17 Production Wells No Violations

-132 and Compliance Notice -

1909720397 2013-08-27 Production Wells No Violations On the day of my inspection, I witnessed eight inch surface casing standing from the ground with four and a half inch production casing and a ball valve with a concoil catcher on top, the four and a half inch ball valve under the concoil catcher was in the closed position. There is two and a half inch tubing leading from the concoil catcher into the separator, the gauge on top of the separator indicated no pressure, there are two small gauges on the side of the separator reading four pounds each, there is also a one inch ball valve that is in the open position with one inch plastic orange gas line attached to the valve leading from the separator going over the hill. The production tank and containment dike has been removed from the well location, there is no I.D. posted at the well site.
1995445811 2005-12-22 Production Wells No Violations STATUS CHECK
2063069904 2011-12-12 Production Wells Violations Noted I received a complaint from the landowner of an idle well on the property and of a possible leaking tank within dike area. Upon inspecting the site I found the well is equipped with 8 surface casing , 4.5 production casing and a concoil catcher on top. It is being used for domestic purposes only and there has been no production reported on this well since 2009. There is no identification on either tank or wellhead. There is oil and other waste within dike area.

Plug, produce or apply for temporary inactive status. Cleanup/remediate and properly dispose of oil and other waste in containment area. If placed into production, proper identification must be posted and report production as required by law. Failure to comply may result in bond forfeiture.

442442151 2016-9-13 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2063069904 US-OH-121024 2011-12-14 Failure to legibly identify well
2063069904 US-OH-121025 2011-12-14 Well shall be plugged
2063069904 US-OH-121026 2011-12-14 Nonproduction; well shall be plugged or placed in temporary inactive status
2063069904 US-OH-121027 2011-12-14 Statement of annual production not filed

For data sources see[9]

References