34-059-20602

Well Details

Well ID: 34-059-20602
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Richland Township
Operator Name: MILEY GAS COMPANY
Well Pad ID:
Farm/Lease Name: MWCD
License Status: Final Restoration
License Date: 2016-06-07
Spud Date: 1954-03-23
Spud Drilling Contractor:
Final Drill Date: 1954-04-15
Well Total Depth: 654.00 ft
Configuration: Vertical
Latitude: 39.930000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1954-03-23 Change in location per doug bennett inspection 3-8-16 ALE CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 6/2/2016 CM.
Completed 1954-04-15 Change in location per doug bennett inspection 3-8-16 ALE CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 6/2/2016 CM.
Reached Total Depth 1954-04-15 Change in location per doug bennett inspection 3-8-16 ALE CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 6/2/2016 CM.
Change of Owner 2016-06-02 Operator changed from 9998, HISTORIC OWNER to 5429, MILEY GAS COMPANY
APP 2016-06-07 Proposed Formations:SHALE, Issued Date:6/7/2016, Expired Date:6/7/2018 12:00:00 PM, Drilling unit acres:100, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-08-20 Change in location per doug bennett inspection 3-8-16 ALE CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 6/2/2016 CM.
Record Last Modified 2017-05-25 Change in location per doug bennett inspection 3-8-16 ALE CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 6/2/2016 CM.
Construction Permit Expires 2018-06-07 Change in location per doug bennett inspection 3-8-16 ALE CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 6/2/2016 CM.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JANCO WELL OPERATION 0.00 37.00 0
2016 MILEY GAS COMPANY 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JANCO WELL OPERATION Brine 0 0
2016 MILEY GAS COMPANY Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1120596772 2009-2-25 0:00: PW No Violations
-1779834419 2016-8-16 0:00: PW No Violations 2.00
-188204405 2016-3-7 0:00:0 PW No Violations 1.50
-718171017 2016-3-29 0:00: PW No Violations 1.00
0158491379 2016-09-07 Plug / Plug Back No Violations On the day of my inspection I witnessed the location has been graded with seed and straw in place.
0188204405 2016-03-07 Production Wells No Violations On the day of my inspection I witnessed the well was equipped with 6.625 inch casing, 2 inch tubing and rods with valves in the closed position. Production equipment included 2-100bbl tanks shared with 20711, 22381 and 22159 within an earthen dike. Jeff Miley of Miley Gas Co. claims he is the owner of the said well and is trying to get it transferred into his name so that it can be plugged.
0718171017 2016-03-29 Production Wells No Violations On the day of my inspection I met with Muskingum County Watershed District Representatives Mark Swiger, John Watkins and Brad Janssen along with Miley Gas Co. Owner Jeff Miley to discuss upcoming plugging of well, pit placement and erosion control measures for the location.
0738237694 2016-08-18 Production Wells No Violations On the day of my inspection I witnessed Miley Gas Co. rigged up over the 6.625 inch casing. Appalachian Well Surveys was onsite and perforated the 6.625 inch casing at 340 feet with 4 shots and at 125 feet with 4 shots. MGC will trip tubing back in and commence plugging on Monday.
1120596772 2009-02-25 Production Wells No Violations WELL IS IN PRODUCTION.
1343998016 2016-08-22 Plug / Plug Back No Violations On the day of my inspection I witnessed cement remained at the surface and Miley Gas Co. (MGC) cut casing off 30 inches below grade. MGC closed the pit and began rigging down to move back to the 34059207110000 OK Rich Oil 7 to trip 2 inch tubing back in and commence plugging this week.
1471525424 2016-08-16 Plug / Plug Back No Violations Accompanied Doug Bennett on inspection, inspection revealed company removing 2 inch diameter tubing from well. Preparing to plug well, see Inspector Doug Bennett inspection report for further detail.
1471701733 2016-08-20 Plug / Plug Back No Violations On the day of my inspection I witnessed Miley Gas Co. (MGC) had tripped 2 inch tubing into 654 feet. Cemenco Services Inc. was onsite gained circulation and pumped a 5 barrel gel spacer and then pumped a 200 foot 36 sack Class A bottom hole cement plug from 654 feet to 454 feet. Cement was displaced with 1.7 barrels of fresh water. MGC tripped 2 inch tubing to 400 feet and Cemenco gained circulation and pumped a 100 foot 17 sack Class A bottom of the surface cement plug from 400 feet to 300 feet with the casing perforated at 360 feet. Cement was displaced with 1.1 barrels of fresh water. MGC tripped 2 inch tubing to 160 feet and Cemenco gained circulation and pumped a 160 foot 17 sack Class A bottom of the surface cement plug from 600 feet to surface with the casing perforated at 125 feet. MGC tripped 2 inch tubing out and Cemenco topped off cement with cement staying at the surface. Instructed operator to cut casing off 30 inches below grade and install metal plate identifying well and reclaim according to ORC 1509.072B.
1480964702 2016-12-05 Final Restoration No Violations On the day of my inspection I witnessed that the site passed final restoration according to ORC 1509.072B.
158491379 2016-9-7 0:00:0 PB No Violations 0.50
1779834419 2016-08-16 Production Wells No Violations On the day of my inspection accompanied by ODNR Customer Service Assistant Jimmy Wiles, I witnessed Miley Gas Co. (MGC) finish tripping 2 inch tubing from well bore. MGC plans to perforate the casing and commence plugging operations later this week.
738237694 2016-8-18 0:00: PW No Violations 2.50

For data sources see[7]