X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22098

Well Details

Well ID: 34-055-22098
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: PERELMAN
License Status: Producing
License Date: 2009-07-21
Spud Date: 2009-08-26
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2009-08-31
Well Total Depth: 3786.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-07-21 Proposed Formations:CLINTON, Issued Date:7/21/2009, Expired Date:7/21/2010 6:00:00 AM, Drilling unit acres:29.67, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-08-31
Completion Report Received 2009-10-06
Construction Permit Expires 2010-07-21
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-12-30 3598 3647 34
3598 3647 34
3598 3647 34

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 66510 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 CUTTER EXPLORATION INC 30132.00 560.00 365
2011 CUTTER EXPLORATION INC 40042.00 481.00 0
2012 CUTTER EXPLORATION INC 13414.00 0.00 366
2013 CUTTER EXPLORATION INC 8865.00 251.00 365
2014 CUTTER EXPLORATION INC 12553.00 213.00 365
2015 CUTTER EXPLORATION INC 12044.00 111.00 365
2016 CUTTER EXPLORATION INC 11094.00 85.00 365
2017 CUTTER EXPLORATION INC 114.00 5834.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 CUTTER EXPLORATION INC Brine 159 365
2011 CUTTER EXPLORATION INC Brine 80
2012 CUTTER EXPLORATION INC Brine 32 366
2013 CUTTER EXPLORATION INC Brine 0 365
2014 CUTTER EXPLORATION INC Brine 30 365
2015 CUTTER EXPLORATION INC Brine 0 365
2016 CUTTER EXPLORATION INC Brine 30 365
2017 CUTTER EXPLORATION INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-18787729 2010-10-27 0:00 UP No Violations
-2092488643 2013-5-28 0:00: UP No Violations
0018787729 2010-10-27 UrbanProduction Wells No Violations Lease road is stable. Annulus vented through charcoal filter. 2 100Bbl tanks and one poly tank in the battery. Spacing is correct. Need to review files to confirm location of the tank battery is correct.
1015223438 2017-02-10 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The last reported production for this well was in 2015. The tank battery consisted of two 100 BBL production tanks, one 50 BBL poly brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. Tank valves were equipped with flat plugs. The tank battery was diked and fenced with a locked man door. The wellsite did not have any signage associated with it, so I contacted Mark Turpak from Cutter about installing signage. The lease access was stable.
1309965128 2011-07-06 Preliminary Restoration No Violations Well is a rabbit well. Board on Board fence has been installed around the wellhead and tank battery. Man door to the battery was locked. Lock on man door to the well is broken. Identification sign needs posted, sign needs posted on the outside of fence. Annulus has a pop off on it, annulus gas is vented through the charcoal filter in the tank battery. Spacing between the production tanks is 5 inches too close. Spacing between the production tanks and the separator is correct. Tank battery fence only has a single door. Affected area has been reclaimed. Lease road is stable. No gate on lease road, drive is also a primary driveway. There is erosion on the bank at the stream crossing. Bank of the stream crossing needs repair seeding. Operator has recently completed repair work on the stream crossing. Company will be contacted by e-mail regarding need repairs.
2092488643 2013-05-28 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open to a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a wood fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The identification needs placed on the tank battery and the wellhead. I left a message for the well tender to get the signs up. The lease road is in stable condition.

For data sources see[9]