34-055-22007

Well Details

Well ID: 34-055-22007
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Mesopotamia Township
Operator Name: DAVID R HILL INC
Well Pad ID:
Farm/Lease Name: BYLER W & E
License Status: Producing
License Date: 2007-12-11
Spud Date: 2008-01-06
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2008-01-11
Well Total Depth: 4222.00 ft
Configuration: Vertical
Latitude: 41.470000
Longitude: -81.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-12-11 Proposed Formations:CLINTON, Issued Date:12/11/2007, Expired Date:12/10/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-01-11
Completion Report Received 2008-03-27
Construction Permit Expires 2008-12-10
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-04 3973 4070 104
3973 4070 104
3973 4070 104

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72830 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 DAVID R HILL INC 5743.00 845.00 305
2009 DAVID R HILL INC 5111.00 804.00 365
2010 DAVID R HILL INC 4231.00 477.00 365
2011 DAVID R HILL INC 2755.00 320.00 365
2012 DAVID R HILL INC 2279.00 271.00 366
2013 DAVID R HILL INC 1900.00 311.00 365
2014 DAVID R HILL INC 2218.00 211.00 365
2015 DAVID R HILL INC 1459.00 207.00 365
2016 DAVID R HILL INC 1776.00 206.00 365
2017 DAVID R HILL INC 1507.00 152.00 365
2018 DAVID R HILL INC 861.00 122.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 DAVID R HILL INC Brine 491 305
2009 DAVID R HILL INC Brine 413 365
2010 DAVID R HILL INC Brine 254 365
2011 DAVID R HILL INC Brine 134 365
2012 DAVID R HILL INC Brine 67 366
2013 DAVID R HILL INC Brine 153 365
2014 DAVID R HILL INC Brine 160 365
2015 DAVID R HILL INC Brine 73 365
2016 DAVID R HILL INC Brine 68 365
2017 DAVID R HILL INC Brine 65 365
2018 DAVID R HILL INC Brine 57 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1136142143 2015-7-2 0:00:0 PW No Violations 0.50
-1520655394 2013-12-26 0:00 PW No Violations
-931367514 2009-7-22 0:00: PL No Violations
0931367514 2009-07-22 Preliminary Restoration No Violations Well is in good repair. Site is in good repair.
1136142143 2015-07-02 Production Wells No Violations I responded to a oil and gas leak reported by Lt. Anderson of the Middlefield Fire Department. Upon arrival, I found Lt. Anderson on location approximately 0.3 miles west of the entrance to the tank battery. The leak was located along Nauvoo Road next to a telephone pole. Upon further inspection, I found a gas leaking from a sales line directly next to a telephone pole. The gas leak had created a small, mud volcano and threw mud onto the telephone pole. I observed no free oil. Lt. Anderson stated the well tender, Terry McIntyre, was enroute to the location. Upon arrival, Mr. McIntyre stated the poles were only a year old and may have nicked the poly sales line when the hole was drilled. Mr. McIntyre isolated the leak and stated repairs would be made by 7/7/2015. A follow-up inspection would be conducted by 7/8/2015.
1199979670 2008-01-10 Drill / Deepen / Reopen No Violations Operator drill depth was 3949. Operator is drilling on air. Pits are in good repair. Lease road is stable to site. Operator has placed a steel plate in the road before the rig for stability. Drainage is contained on site. Permit posted in the dog house. Blow pipe was surging, no smell of gas noted. I asked driller if they were hitting any gas, he said that it was probably the air pumps surging. HL #1 38 17 inch. CND set at 38 CND was 11.75 32lb pipe. SRF set at 372 8.625 inch pipe. R-3 20lb pipe. 110 sacks of cement ran, 10BBL return to surface.
1520655394 2013-12-26 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well and the tank battery are in good repair. The tank battery consists of a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
2139231861 2010-03-08 Production Wells No Violations One 110bbl tank, 1500 gallon poly tank and mechanical separator in the battery. Id sign is up. Spacing is good. Dike is in good repair. Hatches are closed. Lease road is stable and in good repair.

For data sources see[9]

References