X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-20286

Well Details

Well ID: 34-055-20286
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Farmington Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: HOPKINS
License Status: Final Restoration
License Date: 2016-08-03
Spud Date: 1979-07-15
Spud Drilling Contractor:
Final Drill Date: 1979-07-24
Well Total Depth: 4170.00 ft
Configuration: Vertical
Latitude: 41.370000
Longitude: -81.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-05-03 182 BELDEN & BLAKE CO GeoDate 5/3/79
Original Spud 1979-07-15 R.I. 5-10-79
Completed 1979-07-24 R.I. 5-10-79
Reached Total Depth 1979-07-24 R.I. 5-10-79
Change of Owner 2002-08-06 Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC
Change of Owner 2002-12-12 Operator changed from 1966, PETROX INC to 7033, BROAD STREET ENERGY COMPANY
APP 2004-01-14 Proposed Formations:CLINTON, Issued Date:1/14/2004, Expired Date:1/13/2005 6:00:00 AM, Drilling unit acres:52, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2005-03-01 Operator changed from 7033, BROAD STREET ENERGY COMPANY to 935, BOCOR HOLDINGS, LLC/BOCOR PROD
APP 2016-08-03 Proposed Formations:CLINTON, Issued Date:8/3/2016, Expired Date:8/3/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-08-10 R.I. 5-10-79
Record Last Modified 2017-02-15 R.I. 5-10-79
Construction Permit Expires 2018-08-03 R.I. 5-10-79

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3891 3981 16
3891 3981 16
3891 3981 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1146 Bbl 90000
N2 0 147 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 POWER GAS MARKETING & TRANS 1155.00 346.00 0
1986 BELDEN & BLAKE CORPORATION 455.00 323.00 365
1987 BELDEN & BLAKE CORPORATION 544.00 181.00 365
1988 BELDEN & BLAKE CORPORATION 182.00 229.00 123
1992 BELDEN & BLAKE CORPORATION 0.00 60.00 15
1993 BELDEN & BLAKE CORPORATION 383.00 303.00 111
1994 BELDEN & BLAKE CORPORATION 500.00 223.00 213
1995 BELDEN & BLAKE CORPORATION 690.00 405.00 357
1996 BELDEN & BLAKE CORPORATION 498.00 420.00 305
1997 BELDEN & BLAKE CORPORATION 849.00 328.00 274
1998 BELDEN & BLAKE CORPORATION 845.00 290.00 271
1999 BELDEN & BLAKE CORPORATION 555.00 343.00 208
2000 BELDEN & BLAKE CORPORATION 73.00 192.00 324
2001 BELDEN & BLAKE CORPORATION 0.00 204.00 290
2002 BROAD STREET ENERGY COMPANY 0.00 0.00 28
2003 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2004 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2005 BROAD STREET ENERGY COMPANY 0.00 0.00 48
2006 BOCOR HOLDINGS, LLC 465.00 82.00 365
2007 BOCOR HOLDINGS, LLC 1252.00 435.00 365
2008 BOCOR HOLDINGS, LLC 777.00 274.00 365
2009 BOCOR HOLDINGS, LLC 753.00 304.00 365
2010 BOCOR HOLDINGS, LLC 252.00 248.00 365
2011 BOCOR HOLDINGS, LLC 283.00 269.00 365
2012 BOCOR HOLDINGS, LLC 226.00 89.00 366
2013 BOCOR HOLDINGS, LLC 0.00 59.00 365
2014 BOCOR HOLDINGS, LLC 0.00 0.00 0
2016 BOCOR HOLDINGS, LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 POWER GAS MARKETING & TRANS Brine 0 0
1986 BELDEN & BLAKE CORPORATION Brine 155 365
1987 BELDEN & BLAKE CORPORATION Brine 107 365
1988 BELDEN & BLAKE CORPORATION Brine 142 123
1992 BELDEN & BLAKE CORPORATION Brine 11 15
1993 BELDEN & BLAKE CORPORATION Brine 159 111
1994 BELDEN & BLAKE CORPORATION Brine 80 213
1995 BELDEN & BLAKE CORPORATION Brine 477 357
1996 BELDEN & BLAKE CORPORATION Brine 225 305
1997 BELDEN & BLAKE CORPORATION Brine 121 274
1998 BELDEN & BLAKE CORPORATION Brine 235 271
1999 BELDEN & BLAKE CORPORATION Brine 122 208
2000 BELDEN & BLAKE CORPORATION Brine 76 324
2001 BELDEN & BLAKE CORPORATION Brine 153 290
2002 BELDEN & BLAKE CORPORATION Brine 0 18
2003 BROAD STREET ENERGY COMPANY Brine 0 0
2004 BROAD STREET ENERGY COMPANY Brine 0 0
2005 BROAD STREET ENERGY COMPANY Brine 0 48
2006 BOCOR HOLDINGS, LLC Brine 0 365
2007 BOCOR HOLDINGS, LLC Brine 386 365
2008 BOCOR HOLDINGS, LLC Brine 284 365
2009 BOCOR HOLDINGS, LLC Brine 219 365
2010 BOCOR HOLDINGS, LLC Brine 664 365
2011 BOCOR HOLDINGS, LLC Brine 920 365
2012 BOCOR HOLDINGS, LLC Brine 828 366
2013 BOCOR HOLDINGS, LLC Brine 0 365
2014 BOCOR HOLDINGS, LLC Brine 0 0
2016 BOCOR HOLDINGS, LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1064277194 2016-9-8 0:00:0 FR No Violations
-353443638 2014-5-2 0:00:0 PW No Violations
0353443638 2014-05-02 Production Wells No Violations My inspection found the motor for the pump jack has been removed from the well. I had the company plumb the annulus up to a guage in may. The guage on the annulus was not working and a new guage read the annulus had 20 psi on it. The casing did not have any pressure on it. The company still intends on using the well as a swab well. The tank battery consists of a 210 BBL production tank, a 25 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery. The tank battery and lease road are being shared by permit number 2-0769.
1064277194 2016-09-08 Final Restoration No Violations I conducted a final restoration inspection of this well. The wellsite has been restored and is stable with no erosion issues. The production equipment is remaining on site because it is shared with well 34-155-2-0769. The lease access is remaining per landowner waiver. Final restoration can be passed.
1369059103 2013-05-20 Production Wells No Violations My inspection found the annulus had been plumbed up into a guage as requested. The guage on the tubing, the casing, and the annulus read 0 psi. I placed a call to Jim Paumier of Bocor and he informed me the well has a hole in the tubing and a service rig was scheduled to come out and fix the issue. I also asked him to reclaim a section of the field that the flow line had been replaced and to clean up the scrap pipe around the pump jack. He stated he would have the issues taken care of.
1421853414 2015-01-21 Production Wells No Violations My inspection found no changes since my last inspection. The guages on the 8 5/8 casing, 4.5 casing and the tubing all read zero psi. The valves on the well are closed. The production tank and the brine tank are empty. The vales on both separators are closed. The production chart has not been changed since the last one was put on in March of 2013. The landowner states the well has not produced since 2012. The company has reported production for 2013. The company attempted to apply for temporary inactive status but was denied by Permitting due to the well needs to have not produced for two years. I will continue to monitor the wells status and the company will contact me before performing any operations at the location.
1460547160 2016-04-12 Production Wells Violations Noted My inspection found the well to be equipped with a pumpjack. The motor has been removed from the pumpjack. The valves on the wellhead are in the closed position. The tank battery consists of a 210 BBL production tank, a 35 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery. The lease road is in stable condition. The last year of reported production for the well is 2013. I have contacted Kevin Hutchinson of Bocor Holdings about the well. The well owner/operator shall submit a written plugging schedule to Inspector Perry at 3575 Forest Lake Dr. Suite 150 Uniontown, OH 44685 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
1855770136 2013-04-04 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank, a 35 BBL brine tank, and two mechanical separator. The proper identification was located on the tank battery and pump jack. The lease road is in stable condition.
1996706797 2013-09-16 Production Wells No Violations I was on location today at the request of the landowner. He stated the pump jack had been removed and that the guage on the annulus was not functioning. The well is still equipped with a pump jack. I had the company plumb the annulus up to a guage in may. The guage on the annulus was not working and a new guage read the annulus had 20 psi on it. The casing did not have any pressure on it. The company has informed me that they will be converting the well into a swab well. The tank battery consists of a 210 BBL production tank, a 25 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery. The tank battery and lease road are being shared by permit number 2-0769.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1460547160 US-OH-113332 2016-06-17 Well shall be plugged

For data sources see[9]

References