{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":38.74,"lon":-82.3,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Gallia | |
| Municipality: Harrison Township | |
| Operator Name: CONTINENTAL RESOURCES INC | |
| Well Pad ID: | |
| Farm/Lease Name: MASSIE KATHRYN N & NOEL F | |
| License Status: Final Restoration | |
| License Date: 2009-06-18 | |
| Spud Date: 2008-08-02 | |
| Spud Drilling Contractor: S W JACK DRLG | |
| Final Drill Date: 2008-08-31 | |
| Well Total Depth: 2779.00 ft | |
| Configuration: Horizontal | |
| Latitude: 38.740000 | |
| Longitude: -82.300000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2008-01-02 | Proposed Formations:LOWER HURON SHALE AND/OR OHIO SHALE, Issued Date:1/2/2008, Expired Date:1/1/2009 6:00:00 AM, Drilling unit acres:40.93, Proposed Well Type:OG, Proposed Well Class:EW |
| Change of Owner | 2008-05-29 | Operator changed from 7910, EPSILON ENERGY USA INC to 8380, CONTINENTAL RESOURCES INC |
| APP | 2008-06-10 | Proposed Formations:LOWER HURON/OHIO SHALE, Issued Date:6/10/2008, Expired Date:6/10/2009 6:00:00 AM, Drilling unit acres:40.93, Proposed Well Type:OG, Proposed Well Class:EW |
| APP | 2008-08-06 | Proposed Formations:LOWER HURON/OHIO SHALE, Issued Date:8/6/2008, Expired Date:8/6/2009 6:00:00 AM, Drilling unit acres:54.7, Proposed Well Type:OG, Proposed Well Class:EW |
| Reached Total Depth | 2008-08-31 | |
| Completion Report Received | 2009-01-12 | |
| Correction to Well | 2009-01-23 | CORRECTION TO SURFACE AND TARGET INFORMATION. NEW SURFACE INFORMATION: FOOTAGE= 771'SL & 1398'WL OF SEC. 24; X= 2, 055,496 AND Y= 272,746. NEW TARGET INFORMATION: FOOTAGE= 1410'NL & 3869'WL OF SEC. 23; X= 2,057,802; Y= 270,443; AND ELEV.= 630'. |
| APP | 2009-06-18 | Proposed Formations:LOWER HURON/OHIO SHALE, Issued Date:6/18/2009, Expired Date:6/18/2010 6:00:00 AM, Drilling unit acres:54.7, Proposed Well Type:OG, Proposed Well Class: |
| Plugged/Abandoned | 2009-10-06 | |
| Construction Permit Expires | 2010-06-18 | |
| Record Last Modified | 2015-09-24 |
For data sources see[2]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| Not Treated | 0 | 0 | 0 | PER PHONE CONVERSATION WITH OPERATOR'S PRODUCTION ENGINEER ON 4/23/09, DUE TO INADEQUATE NATURAL SHOWS THE WELL WAS NOT FRACED … IT WAS NOT TURNED ON, AND IS CURRENTLY UP FOR SALE … GM |
For data sources see[3]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2008 | CONTINENTAL RESOURCES INC | 0.00 | 0.00 | 0 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2008 | CONTINENTAL RESOURCES INC | Brine | 0 | 0 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1206843050 | 2009-6-25 0:00: | PB | No Violations | |
| -1323257430 | 2009-5-7 0:00:0 | PL | No Violations | |
| -1588809931 | 2009-9-22 0:00: | PB | No Violations | |
| -1759665325 | 2009-7-20 0:00: | AM | No Violations | |
| -1774108735 | 2009-7-15 0:00: | PB | No Violations | |
| -18217889 | 2009-9-9 0:00:0 | AM | No Violations | |
| -1832026932 | 2009-6-15 0:00: | PB | No Violations | |
| -681497094 | 2009-1-14 0:00: | CT | No Violations | |
| -735646087 | 2008-6-19 0:00: | DD | No Violations | |
| -749698756 | 2010-2-3 0:00:0 | FR | No Violations | |
| -865788309 | 2008-8-20 0:00: | DD | No Violations | |
| -892920861 | 2009-6-18 0:00: | PB | No Violations | |
| 0018217889 | 2009-09-09 | Administrative Inspection | No Violations | Received a call from Ed Kohler (Continental). Ed wanted to know why MRM changed his plug plan. I explained that we had a meeting with myself, Robert Stonerock, Tom Tomastik, and Steve Opritza. To review the plug plan submitted by Continental. I reviewed the Divisions Concerns about the perf and squeeze. I also explained our request for a segmented bond log. Ed was not satisfied with our discussion. I suggested that he talk to someone else from the meeting. I referred him to Tom Tomastik and Steve Opritza. Ed has requested specifications on the vault and vent system. |
| 0068128969 | 2009-06-24 | Plug / Plug Back | No Violations | Tag TOC plug at 3226 MD. Tubing set at 3221 MD. Was able to pump through tubing and achieve circulation to surface with water. They did not use a mud anchor on the tubing. Circulate gel and flake to surface. Pump cement plug from 3221 to 2700. WOC. |
| 0118420148 | 2009-07-24 | Drill / Deepen / Reopen | No Violations | Installed 300psi gauge on swedge, could not measure anything on gauge. Closed needle valve and removed gauge. Opened needle valve could hear and see gas (low pressure and continuous volume) Closed and opened needle valve multiple times each time pressure increased slightly then flowed at constant rate. Pressure is low around 35psi. |
| 0124744039 | 2009-02-17 | Administrative Inspection | No Violations | Called Merl Richards (company consultant over seeing the well). I told Merl that the well is still leaking gas around the outside of the 7 casing. I asked to set up a meeting so we could discuss cement procedures and I requested all records for the well that pertain to the drilling and cement jobs for this well in addition to a detailed list of the casing and any equipment that was used down hole. |
| 0237434938 | 2009-10-07 | Plug / Plug Back | No Violations | Inspection of well after waiting 24 hours. No gas was observed after 2 inch valve was opened. Gas meter showed no gas when placed over the top of the open valve. I gave the ok to cover up the casing which had been previously cut off 3 feet below ground level. |
| 0302496161 | 2009-10-03 | Plug / Plug Back | No Violations | Plug job. Cement retainer set at 152 feet. Ran 5 joints tubing 151 feet. Water circulated to surface. Good cement returns to surface. Cement stayed at surface. |
| 0306787975 | 2014-12-04 | Preliminary Restoration | No Violations | Preliminary Restoration requirements met. |
| 0407811826 | 2009-06-30 | Plug / Plug Back | No Violations | Witnessed plugging activity. No gas observed behind the 7 casing and circulation observed on all three plugs. |
| 0597308405 | 2008-08-03 | Drill / Deepen / Reopen | No Violations | Surface casing cement job. Spud date 8/2/2008. TD 681. 657 of 9 5/8 in a 12.25 hole. 59 of 13 conductor set in a 17.5 hole. At 25 had a damp area. At 375 they hit a 1/4 stream of water. Ran one basket on the 8th joint. Used 5 centralizers. Well had good circulation and good cement returns to surface. Cement stayed at surface. |
| 0653513675 | 2008-08-11 | Plug / Plug Back | No Violations | Well was plugged back on 8-10-2008. From 1850 to 1600. This is a kick off plug for drilling horizontally. After logging it was determined that a possible fault was located between 1600 and 1500. 130 sacs of class A cement were used. The cement did not set up and is causing problems with the drilling of the horizontal curve. |
| 0681497094 | 2009-01-14 | Completion Testing | No Violations | Gas and brine are bubbling around the wellhead. Appears to be coming from the backside of the 7 casing. Similar to the Corbin well. I took a video with my digital camera. I tested the water with a high end Quantab. The tab measured 7.8 on the strip which is 4907 ppm cl. The temperature was 20 F and every thing on location was frozen except at the well head where the brine was bubbling steadily. |
| 0735646087 | 2008-06-19 | Drill / Deepen / Reopen | No Violations | GPS on the well stake. Site is being built now. They are building a gravel entrance and will stone most of the location. This is an horizontal well. The same crew that did the Richfield wells is doing this well. Merl Richards, Jimmy Ray and the SW Jack rig # 8. |
| 0749698756 | 2010-02-03 | Final Restoration | No Violations | Site is graded. Have established good vegetative cover on location. Landowner will use site for hay field. Gravel pile has been left at request of landowner. |
| 0865788309 | 2008-08-20 | Drill / Deepen / Reopen | No Violations | Drill pit looks good. They hit a 3 stream of brine at 2500 in the 88 degree section of the horizontal curve. Plan on doing a squeeze job to seal off the water. |
| 0892920861 | 2009-06-18 | Plug / Plug Back | No Violations | Fisher Well Surveys (Wire line) Cut the 4.5 casing at 3596 Using a coiled tubing pressure activated firing system custom fitted to the end of the tubing. Pressured up to 2500psi on the tubing to set off charge. |
| 1068146688 | 2009-08-13 | Production Wells | No Violations | Accompanied Mr. Jon Scott and Mr. Robert Stonerock, Oil & Gas South Region Supervisor with the collection of gas samples from this well. |
| 118420148 | 2009-7-24 0:00: | DD | No Violations | |
| 1206843050 | 2009-06-25 | Plug / Plug Back | No Violations | Tag TOC plug at 2714 MD. Load hole and ran wire line down to 2561 and log 7. |
| 1227285075 | 2009-06-29 | Plug / Plug Back | No Violations | Arrived at 8:30 am to check the status of plugging activity. It was noted that the immediate area around the well bore has been excavated. The Company Representative, Mr. Greg Lawson states 40 lbs on 7 casing. Observed soap, in bottle, sprayed outside the 7 casing. No gas was observed behind the 7 at the surface. Due to a meeting that had been organized to discuss the plugging of this well, Mr. Tom Tomastik was advised of the well status and proposed plugs by telephone. The plugs were approved. It was also recommended to leave the backside open and to not shut-in when plugging. This information along with the plug intervals were provided to Mr. Lawson whom, agreed with the proposed plans. |
| 1227537609 | 2008-10-30 | Completion Testing | No Violations | Pit is open. Pit liner is in good shape, no tears in lining. |
| 124744039 | 2009-2-17 0:00: | AM | No Violations | |
| 1323257430 | 2009-05-07 | Preliminary Restoration | Violations Noted | Spud date 8-2-08, Restoration due 5-2-09. Site is rutted with standing water. No attempt to vegetate site. Site is bare ground. No identification on well. Well is equipped with tubing. Robert Stonerock (South Region Supervisor) accompanied me on the inspection. Well is leaking gas and fluid around the backside of the 7 inch casing. Gas is bubbling like a rolling boil in a 6 foot pool of brine at the wellhead. I called Merl Richards (company representative) at 6:18 pm on 5-7-09 and informed him of the violations. |
| 1372444904 | 2009-06-22 | Plug / Plug Back | No Violations | Ran tubing to 3605 MD. Pumped 170 bbls unable to get circulation to surface. Pumped cement plug from 3605 to 3200 took sample to determine when safe to tag TOC plug. Had trouble could not clear tubing after running back to tag 1st plug. Pulled all tubing and had cement inside 35 joints of tubing. |
| 1588809931 | 2009-09-22 | Plug / Plug Back | No Violations | TD 711. Cast Iron Bridge Plug set at 695 Pressure tested to 586 psi for 15 minutes. At 15 minutes pressure was 563psi. Tubing ran to 688 Circulate gel to surface. Pump cement 17 bbls Class A 15.6 lb (81 sacks). Plug set from 688 to 275. Pulled tubing to 275 and pumped and circulated cement to surface. Cement stayed at surface. |
| 1708307867 | 2009-04-08 | Administrative Inspection | No Violations | Talked to Merl Richards today. Merl is sending Brian Stephens to meet with me next week to discuss issues on cementing and plans to correct gas and brine leak on back side of 7 casing. |
| 1759665325 | 2009-07-20 | Administrative Inspection | No Violations | Called Ed Kohler (Continental) left message that well is leaking gas from inside 7 casing. And that they will have to drill out and re plug well. |
| 1774108735 | 2009-07-15 | Plug / Plug Back | No Violations | Rose excavating informed me that they noticed gas leaking inside the 7 casing when they were setting up to cut the casing off with a torch. |
| 1782969900 | 2009-10-06 | Plug / Plug Back | No Violations | Mix 1 bag Portland Cemex type 1 (94lbs) with 1.5 bags Gypsum ( Plaster of Paris and Portland Cement). Poured mixture into inverted 4.5 by 2 swedge ( used as a funnel) that was connected to a 2 inch valve. Removed swedge and installed a 2 inch bushing with a test rig attached onto the valve. 200 psi of Nitrogen applied through the 2 inch valve. Small leaks were observed on the top welds of a fabricated 7 inch by 2 inch swedge. Repairs were attempted to seal the leaks. Maintained 200 psi Nitrogen for 15 minutes. Increased pressure to 300psi shut 2 inch valve and removed test rig. Leave valve closed a minimum of 24 hours. |
| 1832026932 | 2009-06-15 | Plug / Plug Back | No Violations | Pulling tubing out in preparation of plug job. |
| 1886389537 | 2009-09-30 | Plug / Plug Back | No Violations | Well is shut in at surface with a 7 by 2 swedge with valve and gauge attached. |
| 1913585495 | 2008-12-19 | Completion Testing | No Violations | A pool of fluid is surrounding the wellhead approx 6 feet in diameter. There is a constant bubbling like a rolling boil that is coming up beside the casing. I was able to extend a small bucket and capture some of the fluid bubbling at the casing. An high range Quantab was used. It measured 8 on the strip that is 5408 ppm Cl. I took a video of the leak. The drill pit has been filled in. I used my gas detector and could not detect any explosive levels near the well. The wind was blowing and could have dispersed the gas. I have informed Merl Richards of this problem and he is working on getting the records to me so that we can determine what is causing the leak. |
| 1955412475 | 2009-05-13 | Production Wells | No Violations | No identification. Well has gas bubbling around the backside of the 7 casing. Water around wellhead was tested with an high end Quantab results were 4.6 on the strip= 1364ppm cl. Preliminary restoration not completed. Site rutted up and void of vegetative growth. Took video of the well. |
| 1994433432 | 2008-11-12 | Drill / Deepen / Reopen | No Violations | Pit liner is in good shape. Pit has fluid in it. There is a gas leak around the back side of the 7. It is bubbling steady. I have talked to Jimmy Ray about this leak. |
| 2047086555 | 2009-08-03 | Plug / Plug Back | No Violations | Wellhead has water around it. Tested water with high end Quantabs measured 4 on strip = 1059 ppm cl. Gas leak on backside of 7 casing. Took video of leak. |
| 237434938 | 2009-10-7 0:00: | PB | No Violations | |
| 302496161 | 2009-10-3 0:00: | PB | No Violations | |
| 306787975 | 2014-12-4 0:00: | PL | No Violations | 0.20 |
| 407811826 | 2009-6-30 0:00: | PB | No Violations | |
| 597308405 | 2008-8-3 0:00:0 | DD | No Violations | |
| 653513675 | 2008-8-11 0:00: | PB | No Violations | |
| 68128969 | 2009-6-24 0:00: | PB | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 1323257430 | US-OH-109246 | 2009-05-08 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
| 1323257430 | US-OH-109247 | 2009-05-08 | Well insufficiently equipped to prevent escape of oil and gas | |
| 1323257430 | US-OH-109248 | 2009-05-08 | Failure to legibly identify well |