Well Details

Well ID: 34-045-21495
Loading map...
Country: United States
State: Ohio
County: Fairfield
Municipality: Bloom Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: STEBOLTON
License Status: Well Drilled
License Date: 2018-08-31
Spud Date: 2013-07-15
Spud Drilling Contractor: FMS DRILLING
Final Drill Date: 2013-07-28
Well Total Depth: 3794.00 ft
Configuration: Vertical
Latitude: 39.780000
Longitude: -82.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-11 Proposed Formations:OHIO SHALE THRU TREMPEALEAU, Issued Date:7/11/2013, Expired Date:7/11/2015 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EDPW
Plugged Back 2013-07-28
Reached Total Depth 2013-07-28
Completion Report Received 2018-08-22
APP 2018-08-31 Proposed Formations:TREMPEALEAU, Issued Date:8/31/2018, Expired Date:8/30/2020 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2018-09-07
Construction Permit Expires 2020-08-30

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-08-31 2913 2976 0
2913 2976 0
2913 2976 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-10-30 H2O 7 199625 Gal 60000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 NORTHWOOD ENERGY CORP 0.00 0.00 0
2015 NORTHWOOD ENERGY CORP 0.00 0.00 0
2016 NORTHWOOD ENERGY CORP 0.00 0.00 0
2017 NORTHWOOD ENERGY CORP 0.00 0.00 0
2018 NORTHWOOD ENERGY CORP 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 NORTHWOOD ENERGY CORP Brine 677 0
2015 NORTHWOOD ENERGY CORP Brine 0 0
2016 NORTHWOOD ENERGY CORP Brine 0 0
2017 NORTHWOOD ENERGY CORP Brine 0 0
2018 NORTHWOOD ENERGY CORP Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1040403886 2018-6-1 0:00:0 PW No Violations 0.20
-1171136631 2018-9-21 0:00: PW No Violations 0.50
-122739477 2013-7-15 0:00: DD No Violations 5.00
-1358745759 2017-10-5 0:00: PW No Violations 1.00
-1427960172 2013-10-30 0:00 DD No Violations 6.00
-147117672 2013-7-20 0:00: DD No Violations 7.00
-248216631 2018-8-10 0:00: PW No Violations 0.60
-587859933 2018-2-26 0:00: PW No Violations 1.50
-597025883 2015-11-18 0:00 PW No Violations 2.00
-690255482 2013-7-22 0:00: DD No Violations 4.00
-76754836 2017-6-14 0:00: PW No Violations 1.00
-994906612 2014-2-21 0:00: DD No Violations 1.00
0033363631 2013-07-17 Drill / Deepen / Reopen No Violations 122 of conductor was set, good cement returns.
0076754836 2017-06-14 Production Wells No Violations Compliance notice follow-up inspection. The well remains idle. The well consists of a wellhead, pumping unit and has the production tubing connected to a half tank. There is rust on the pulleys and the polish rod is dull.
0122739477 2013-07-15 Drill / Deepen / Reopen No Violations FMS drilling has installed the rat hole pipe. I instructed them to seal the annulus to prevent exposing the soil to any drilling fluids. They said they will cement the annulus on the rat and mouse hole pipes.
0147117672 2013-07-20 Drill / Deepen / Reopen No Violations I received a call from Bob Brock, tool pusher for FMS drilling. He stated they would be ready to cement surface casing at 1900 hours. Formation Cementing on site 2130 hours. Good cement returns. 405 of 8.62 surface casing installed.
0180674489 2013-07-21 Drill / Deepen / Reopen No Violations I received a call from FMS drilling to perform a BOP test. The test was 500 PSI for 30 minutes. No loss the test passed.
0248216631 2018-08-10 Production Wells No Violations At 8:39 AM I called Mr. Bill Arnholt who works for Northwood Energy. I left a message for Mr. Arnholt to return my call regarding the status of this well. The well consists of a pumping unit with the valves turned off and a temporary horizontal tank used to test the well.
0587859933 2018-02-26 Production Wells No Violations At 0819 today I called Mr. Bill Arnholt with NorthWood Energy and left a message to return my call. I issued a compliance notice on 10.28.16 for 1509:12(B), well shall be plugged. The well consists of a pumping unit and a temporary horizonal tank they used to test the well. No attempt has been made to bring the well into compliance.
0597025883 2015-11-18 Production Wells No Violations Production well inspection. The well has produced only brine. I have contacted Northwood Energy concerning the status of this well.
0690255482 2013-07-22 Drill / Deepen / Reopen No Violations They have reached 821, no problems, drilling is on schedule.
0994906612 2014-02-21 Drill / Deepen / Reopen No Violations The pits have been filled, the well has not been put into production. I have contacted Northwood Energy to determine when the well will be finished.
1040403886 2018-06-01 Production Wells No Violations At 0753 today I called Mr. Bill Arnholt with Northwood Energy and left a message to return my call. I issued a compliance notice on 10.28.16 for 1509:12(B), well shall be plugged. The well consists of a pumping unit and a temporary horizonal tank they used to test the well. The polish rod is dull and the pulleys are rusty. There has been no change in the status of the well since my last inspection. New picturs were taken during my inspection.
1106770958 2017-11-21 Production Wells No Violations My inspection revealed the well status has not changed. The pulleys on the motor are rusty and the polish rod is dull. There is no fuel line connected to the carburetor. The vales are turned off. There has been no change in the status of this since my last inspection. I have called well owner Northwood Energy find out when the plan on bring the well into compliance. They informed me they will plug the well in 6 months. This time frame allows them to use the production equipment on a well they will drill in Pickaway county.
1171136631 2018-09-21 Production Wells No Violations My inspection revealed the well consists of a pumping unit and a temporary 300 barrel tank that was used to test the well. I have received a plugging permit and a plugging plan from Northwood Energy. The well is scheduled to be plugged when the crop is harvested.
1293346450 2017-08-07 Production Wells No Violations There has been no change in the status of the well. I called Northwood Energy to find out when they plan on bringing the well into compliance.
1358745759 2017-10-05 Production Wells No Violations My inspection today revealed the well is not in production. The well consists of a pumping unit and a horizontal tank. The well has not showed production since it was completed in 2014. The polish rod is dull and the pulleys are rusty. There has been no attempt to bring the well into compliance.
1373906130 2013-07-14 Drill / Deepen / Reopen No Violations The pits are complete, the rig is set up. The site is graded. Bob Brock stated they will spud tonight.
1374244179 2013-07-19 Drill / Deepen / Reopen No Violations FMS drilling is having some problems with drift. They have stopped drilling on air and have switched to mud based fluid. 234 reached at 1030 hours today.
1375042775 2013-07-28 Drill / Deepen / Reopen No Violations FMS drilling reached total depth at 0600 hours. They placed a 100 bottom plug from 3795 to 3695. They will be running 4.5 production string this evening. Northwoods energy geologist has Formation cementing the production string to achieve 1000 of fill up.
1427960172 2013-10-30 Drill / Deepen / Reopen No Violations Producers Services on site at 0630 hours. The well is being stimulated using a slick water frac.
1477656252 2016-10-28 Production Wells Violations Noted
1514295374 2017-12-26 Production Wells No Violations My inspection revealed the well is not in compliance. The well consists of a pumping unit and a 300 barrel horizonal tank. The tank was used to pump into to test the well. I have spoken with Northwood Energy concerning the status of this well. I was told the well would be plugged in approximately 6 months and the production equipment will be used on a new well in Pickaway county.
1547125084 2019-01-10 Production Wells No Violations My inspection revealed the wells status remains unchanged. The well consists of a pumping unit and a temporary tank that was used to test the well. I have a plugging permit for this well and will contact Northwood Energy to find out when the well will be plugged.
1555591523 2019-04-18 Production Wells No Violations My inspection revealed this wells status remains unchanged. The well was cited for 1509:12(B), well shall be plugged. I have a plugging permit for this well and have spoken to plugging contractor Knox Energy. They are waiting on the ground to dry up before plugging this well.
180674489 2013-7-21 0:00: DD No Violations 4.00
2010000093 2013-07-29 Drill / Deepen / Reopen No Violations Production casing has been installed and cemented. FMS is rigging down.
2079081813 2013-07-25 Drill / Deepen / Reopen No Violations FMS drilling is on schedule with their drilling production. They have reached 2854 by 0730 hours this day. No problems were observed.
33363631 2013-7-17 0:00: DD No Violations 2.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1477656252 US-OH-113662 2016-11-03 NONE Well shall be plugged

For data sources see[9]