X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-045-21241

Well Details

Well ID: 34-045-21241
Loading map...
Country: United States
State: Ohio
County: Fairfield
Municipality: Rush Creek Township
Operator Name: GEOPETRO LLC
Well Pad ID:
Farm/Lease Name: RAAB ET AL
License Status: Producing
License Date: 1999-03-18
Spud Date: 1999-09-27
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 1999-10-15
Well Total Depth: 4311.00 ft
Configuration: Vertical
Latitude: 39.720000
Longitude: -82.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-03-18 Proposed Formations:CLINTON THRU KNOX, Issued Date:3/18/99, Expired Date:3/17/00 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EOUT
Original Spud 1999-09-27 RBDMS Rec
Completed 1999-10-15 RBDMS Rec
Reached Total Depth 1999-10-15 RBDMS Rec
Completion Report Received 1999-11-24 RBDMS Rec
Construction Permit Expires 2000-03-17 RBDMS Rec
Last Compliance Report 2012-09-19 RBDMS Rec
Record Last Modified 2017-08-21 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-01-28 4246 4254 0
2000-01-28 4224 4231 0
4207 4211 0
4224 4231 0
4234 4237 0
4246 4254 0
4194 4204 0
4194 4204 0
2000-01-28 4234 4237 0
2000-01-28 4194 4204 0
2000-01-28 4207 4211 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1200 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 GEOPETRO LLC 1072.00 146.00 45
2000 GEOPETRO LLC 26962.00 3184.00 360
2001 GEOPETRO LLC 1921.00 1823.00 365
2002 GEOPETRO LLC 1771.00 2339.00 365
2003 GEOPETRO LLC 344.00 1484.00 365
2004 GEOPETRO LLC 110.00 783.00 365
2005 GEOPETRO LLC 57.00 642.00 365
2006 GEOPETRO LLC 42.00 570.00 365
2007 GEOPETRO LLC 0.00 114.00 365
2008 GEOPETRO LLC 0.00 211.00 365
2009 GEOPETRO LLC 0.00 162.00 365
2010 DEVORE ANTHONY D 0.00 812.00 365
2011 GEOPETRO LLC 0.00 750.00 0
2012 GEOPETRO LLC 0.00 845.00 366
2013 GEOPETRO LLC 0.00 588.00 365
2014 GEOPETRO LLC 0.00 988.00 365
2015 GEOPETRO LLC 0.00 766.00 365
2016 GEOPETRO LLC 0.00 679.00 365
2017 GEOPETRO LLC 0.00 340.00 365
2018 GEOPETRO LLC 0.00 270.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 GEOPETRO LLC Brine 42 45
2000 GEOPETRO LLC Brine 89 360
2001 GEOPETRO LLC Brine 125 365
2002 GEOPETRO LLC Brine 400 365
2003 GEOPETRO LLC Brine 791 365
2004 GEOPETRO LLC Brine 615 365
2005 GEOPETRO LLC Brine 882 365
2006 GEOPETRO LLC Brine 855 365
2007 GEOPETRO LLC Brine 325 365
2008 GEOPETRO LLC Brine 45 365
2009 GEOPETRO LLC Brine 600 365
2010 DEVORE ANTHONY D Brine 19 365
2011 GEOPETRO LLC Brine 15
2012 GEOPETRO LLC Brine 33 366
2013 GEOPETRO LLC Brine 0 365
2014 GEOPETRO LLC Brine 105 365
2015 GEOPETRO LLC Brine 368 365
2016 GEOPETRO LLC Brine 435 365
2017 GEOPETRO LLC Brine 80 365
2018 GEOPETRO LLC Brine 220 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1324211963 2019-4-29 0:00: AD No Violations
-558430988 2007-11-8 0:00: AD No Violations
-777960623 2017-8-17 0:00: AD No Violations 1.00
-942964756 2020-1-17 0:00: AD No Violations 2.00
0001248i11 2001-03-20 Production Wells No Violations No violations noted this date.
0558430988 2007-11-08 Annular Disposal Violations Noted I conducted the inspection at the request of Tom Tomastik. The well is currently in production. The annular disposal is hooked up and in use. The connections are liquid tight and accessible at the well head. The tank battery is located approximately 2100 feet from the well. There is identification posted at the tank battery. There is no identification posted at the well head. The tank battery consists of two 210 barrel tanks and one 50 barrel tank contained within an earthen dike.
0777960623 2017-08-17 Annular Disposal No Violations My inspection showed the well is being pressured up to 318 PSI to determine if the well can continue to be used for annular disposal.
0866643635 2013-10-18 Production Wells No Violations Compliance notice follow up, the well is in compliance, this satisfies the compliance notice.
1186425320 2007-08-01 Annular Disposal No Violations I preformed an integrity test on this AD well with Jeff Fry. The well maintained a pressure of 336 psi for an hour with zero percent loss. This well meets the qualifications necessary for the use of annular disposal.
1248i11 2001-3-20 0:00: PW No Violations
1324211963 2019-04-29 Annular Disposal Violations Noted Our records indicate that the Division has not received the Annular Disposal Annual Report (Form 205) that was due on April 15th for 2018, Please submit the Form 205 to the Division by 5/29/2019.
1327507521 2007-11-08 Annular Disposal No Violations FOLLOW UP TO NOV # -558430988 I conducted the inspection at the request of Tom Tomastik. The well is currently in production. The annular disposal is hooked up and in use. The connections are liquid tight and accessible at the well head. The tank battery is located approximately 2100 feet from the well. There is identification posted at the tank battery. There is no identification posted at the well head. The tank battery consists of two 210 barrel tanks and one 50 barrel tank contained within an earthen dike.
1345552550 2012-08-21 Annular Disposal No Violations Annular Disposal test, 323 PSI at 8:30am, dropped 2.5 PSI in 60 minutes, test passed.
1462373529 2016-05-04 Annular Disposal Violations Noted Our records indicate that the Division has not received the Annular Disposal Annual Report (Form 205) that was due on April 15th for 2015, despite a letter that was sent March 9, 2016 with a deadline of April 15, 2016 to submit the reports requested. RECEIVED
1503061319 2017-08-18 Annular Disposal No Violations My inspection today was to witness the required pressure test of the annulus. The annulus was pressured up to 326 PSI for 1 hour with no loss in pressure. The well passed the mechanical integrity test.
1841913201 2007-11-08 Annular Disposal No Violations FOLLOW UP TO NOV # -558430988 I conducted the inspection at the request of Tom Tomastik. The well is currently in production. The annular disposal is hooked up and in use. The connections are liquid tight and accessible at the well head. The tank battery is located approximately 2100 feet from the well. There is identification posted at the tank battery. There is no identification posted at the well head. The tank battery consists of two 210 barrel tanks and one 50 barrel tank contained within an earthen dike.
1844142506 2019-12-2 0:00: PW No Violations 1.00
866643635 2013-10-18 0:00 PW No Violations 1.00
iDIAN00446 2000-07-03 Preliminary Restoration No Violations
iDIAN004468 2000-7-3 0:00:0 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0558430988 US-OH-126152 2007-11-08 Failure to legibly identify well
1324211963 US-OH-109274 2019-05-09 Failure to file Annular Disposal Report
1462373529 US-OH-113408 2016-07-21 Failure to file Annular Disposal Report

For data sources see[9]

References