X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22199

Well Details

Well ID: 34-035-22199
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: MCNAB UNIT
License Status: Producing
License Date: 2011-11-30
Spud Date: 2012-09-26
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2012-10-03
Well Total Depth: 5808.00 ft
Configuration: Vertical
Latitude: 41.290000
Longitude: -81.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-11-30 Proposed Formations:TREMPEALEAU/BASEMENT, Issued Date:11/30/2011, Expired Date:11/29/2013 12:00:00 PM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2012-09-28 CORRECTION TO CASING PROGRAM, PROPOSED TOTAL DEPTH AND PROPOSED GEOLOGICAL FORMATION.
Reached Total Depth 2012-10-03
Construction Permit Expires 2012-11-29
Correction to Well 2012-11-30 CORRECTION TO PROPOSED GEOLOGICAL FORMATION (ADDED ORISKANY).
Plugged Back 2012-12-03
End of Confidential Data 2013-10-03
Completion Report Received 2016-05-13
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-02-20 3225 3243 18
2013-02-20 5558 5568 18
3225 3243 18
5558 5568 18
3225 3243 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-11-27 H2O 15 1000 Gal 22000 Producers Service Corporation
2012-11-27 H2O 0 45041 Gal 0 Producers Service Corporation I was accompanied today by Steve Tomkins, Lake County Inspector, DOGRM. Well stimulation progressed at 8:35 AM and ended at 10:45 AM. Well stimulation was accomplished using 220 Sacks of sand, 1,000 gallons of 15% HCL Acid and a total of 45,041 gallons of freshwater. 20 shots were placed earlier from 5,568 to 5,558. Hydro frac stimulation was completed with no issues or problems. A separate well visitation report is filed in RBDMS.
2012-10-18 ACID 15 4700 Gal 0 Producers Service Corporation ACID JOB 2
2012-12-11 H2O 15 65605 Gal 50000 Producers Service Corporation
2012-11-27 ACID 15 3800 Gal 0 Producers Service Corporation ACID JOB 1

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 GONZOIL INC 1613.00 0.00 365
2014 GONZOIL INC 19224.00 719.00 365
2015 GONZOIL INC 10745.00 420.00 365
2016 GONZOIL INC 7612.00 298.00 365
2017 GONZOIL INC 5339.00 207.00 365
2018 GONZOIL INC 0.00 95.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 GONZOIL INC Brine 199 365
2014 GONZOIL INC Brine 1193 365
2015 GONZOIL INC Brine 765 365
2016 GONZOIL INC Brine 481 365
2017 GONZOIL INC Brine 483 365
2018 GONZOIL INC Brine 80 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-355842273 2018-6-21 0:00: UP No Violations 0.50
-533192505 2020-7-8 0:00:0 UP No Violations 0.50
-72632048 2012-10-2 0:00: UD No Violations 1.00
-930530036 2015-7-2 0:00:0 UP No Violations
0072632048 2012-10-02 Urban Drill / Deepen / Reopen No Violations Drilling is continuing on this well, with rig drilling on fluid since 8/29/30. Vertical target is the Trempeleau at 5,800. No problems, issues or incidents have been reported.
0355842273 2018-06-21 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. Fittings and connections at the well and battery were secure and free from leakage or problems. The tank lids were closed. The secondary containment was intact and dry. The individual enclosure gates were locked. Production reports were current and up-to-date, but the well was not producing at the time of my inspection. The dedicated portion of the shared-use access road was in good condition with some wash-out forming that may require some mitigation. I walked and inspected the areas surrounding the wellhead and battery and found the natural greenscape to be free from signs of impact or degradation. I notified Gonzoil about the possible need for maintenance at the acess road.
0873132288 2012-09-26 Urban Drill / Deepen / Reopen No Violations Site check for site construction management, pre site and permit conditions met. Set conductor casing 6:00 PM.
0930530036 2015-07-02 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead is comprised of a pump jack unit in a chain-link enclosure. The enclosure gate is locked and secure. Fittings at the wellhead are secure and free from leaks or other issues. There is gas being vented from the 8.625-inch surface casing which should be captured by the system. The load-lines require locks on the valves. I notified the owner about the aforementioned issues and they indicated these items will be resolved immediately.
1354056893 2012-11-27 Urban Drill / Deepen / Reopen No Violations On my visit to this well today I was accompanied by Lake County Inspector Steve Tompkins. Our purpose was to observe the stimulation procedure for this well. A stimulation report has been filed in RBDMS. The well and its components are not installed for service at this time. A follow up inspection will be conducted in approximately 3 weeks.
1354816725 2012-12-03 Plug / Plug Back No Violations The visit to the well today was for the purpose if plugging the well back to the Clinton from the Trempealeau formation. A cement report has been recorded in RBDMS. An updated and corrected permit was issued through permitting.
1467305858 2016-12-06 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: a pump-jack system in a locked and secure chain-link enclosure. Fittings and connections at the wellhead were secure and free from leakage. During a previous inspection, I had noted that gas vented from the surface casing nipple should be plumbed back into the system. That condition had been corrected. Connections and fittings at the battery were secure. The load-lines were locked, which had been noted as a deficiency previously. Tank lids were closed and sealed. The secondary containment was intact and free from signs of leakage or other deficiencies. The dedicated portion of the access road which travels north from the terminus of the driveway was noted to be in good condition. No noted deficiencies at the time of this inspection.
1512417410 2017-05-18 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures located at the back portion of a residential parcel. There is also a indirect heating unit in a board-on-board enclosure located 50 feet north of the wellhead. I found the enclosure gates to be locked and secure, with the following exception: the enclosure gate for the heating unit was broken and not secure. I notified Doug Gonzales about the maintenance needs at the heating enclosure gate. I found the load-line valves to be locked and secure. The tank lids were closed and sealed. The secondary containment was intact and dry. Fittings and connections at the wellhead and battery were secure and free from signs of leakage or problems. I walked the areas around the wellhead and battery which consisted of mixed areas of grass and wooded areas. I did not note any signs of issues or environmental degradation resulting from the on-going production activity.
1632844904 2019-04-24 UrbanProduction Wells No Violations No violations found. All locks, safety equipment, and fencing around well head and tank battery have been installed. Proper identification was posted at well and tank battery.
873132288 2012-9-26 0:00: UD No Violations 3.00

For data sources see[9]

References