X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22170

Well Details

Well ID: 34-035-22170
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BAAY OIL LLC
Well Pad ID:
Farm/Lease Name: CITY OF BEACHWOOD UNIT
License Status: Producing
License Date: 2010-06-14
Spud Date: 2010-07-12
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2010-07-19
Well Total Depth: 3766.00 ft
Configuration: Vertical
Latitude: 41.450000
Longitude: -81.510000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-06-14 Proposed Formations:OHIO SHALE, ORISKANY, NEWTON, CLINTON, Issued Date:6/14/2010, Expired Date:6/14/2011 6:00:00 AM, Drilling unit acres:24.909, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-07-19
Construction Permit Expires 2011-06-14
Completion Report Received 2011-07-13
Change of Owner 2016-01-29 Operator changed from 1304, SEAGULL DEVELOPMENT CORP to 8560, BAAY OIL LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-09-22 3611 3665 23
3611 3665 23
3611 3665 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-08-12 H2O 0 62266 Gal 25000 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 SEAGULL DEVELOPMENT CORP 535.00 128.00 30
2011 SEAGULL DEVELOPMENT CORP 10076.00 581.00 365
2012 SEAGULL DEVELOPMENT CORP 5679.00 194.00 366
2013 SEAGULL DEVELOPMENT CORP 3486.00 132.00 365
2014 SEAGULL DEVELOPMENT CORP 2296.00 65.00 365
2015 SEAGULL DEVELOPMENT CORP 1514.00 126.00 365
2016 BAAY OIL LLC 1969.00 136.00 365
2017 BAAY OIL LLC 1928.00 111.00 365
2018 BAAY OIL LLC 1847.00 117.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 SEAGULL DEVELOPMENT CORP Brine 1680 30
2011 SEAGULL DEVELOPMENT CORP Brine 512 365
2012 SEAGULL DEVELOPMENT CORP Brine 205 366
2013 SEAGULL DEVELOPMENT CORP Brine 0 365
2014 SEAGULL DEVELOPMENT CORP Brine 55 365
2015 SEAGULL DEVELOPMENT CORP Brine 49 365
2016 BAAY OIL LLC Brine 288 365
2017 BAAY OIL LLC Brine 125 365
2018 BAAY OIL LLC Brine 119 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1215571263 2016-2-2 0:00:0 UP No Violations 1.00
-2108739861 2017-10-6 0:00: UP No Violations 0.50
-472450972 2013-7-22 0:00: FR No Violations
-923620917 2010-10-13 0:00 DD No Violations
0472450972 2013-07-22 Final Restoration No Violations Final restoration passed. No sign of well or equipment found at site. Access road removed.
0493691137 2010-07-13 Urban Drill / Deepen / Reopen No Violations Drilling 220 on fluid no violation.
0737752179 2013-02-19 Preliminary Restoration No Violations The wellhead consists of a mechanical plunger lift unit in an 8-foot fenced enclosure. The associated tank battery consists of 1 100-barrel (BBL) tank, 1 50 BBL tank, mechanical separator and metering run, also in a separate, locked enclosure.. The spacing is in accordance with the rule. The tank battery dike is adequate. Safety gear in place as required by 1501:9-9-05. The unit is lacking identification signs. I contacted John Vizner, of Seagull Dev. Corp. and advised him about the need for required signage.
0871744407 2018-01-08 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located within a gated city maintenance facility, with mixed-used commercial use beyond. At the time of this inspection I noted the following: a well with plunger-lift system and associated tank battery is separate chain-link enclosures which were locked and secure. The load-line valves were plugged, locked and secure. The secondary containment was intact. The production reports were current. The well was producing with an active chart record. I walked and inspected the areas surrounding the well and battery and found no indications of problems.
0923620917 2010-10-13 Drill / Deepen / Reopen No Violations Crew working on fencing and grading around tank battery.
1215571263 2016-02-02 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: Ingress and egress from the well area is afforded by the shared asphalt-paved drive and parking areas for the City of Beachwood Service Garage. A wellhead with mechanical plunger lift system is located in a chain-link enclosure at the eastern edge of the parking area. The well enclosure was locked and secure. Fittings and connections at the wellhead were secure and free from leakage. The 8.625-inch casing annulus was exposed with pressure-relief fitting. Areas around the wellhead consisted of turf grass which was free from signs of stress or impact. The tank battery is located 50 feet north of the wellhead on an elevated grassy area just off the asphalt-paved parking. The battery is comprised of one 100-barrel, steel production tank, one 50-barrel poly brine tank. At the time of this inspection, the access gate to the battery was locked and secure. Signage was present. Fittings and connections were secure and free from signs of leakage or problems. Process safety gear and carbon filter system was present. Secondary containment was intact and dry. The load-outs are plugged and secure. I walked the area surrounding the battery and observed normal grassy vegetation with no signs of erosional deficits or impacts associated with the produciton operation. Surface drainage for the area is to a storm sewer catchment located adjacent to the battery. I did observe the following maintenance issue: the load-out valves must be locked.
1279632323 2010-07-19 Urban Drill / Deepen / Reopen No Violations On site for long string cement. Rig crew and service company were wearing FRC uniforms, driller loaned FRC clothing to me. Hole was 7 7/8 inch TD at 3766 feet. Top of the Lockport was 3050 feet. Operator ran 3739 feet of new R-3 11.6 pipe. Fill up needed 816 feet, 816 X .2278 / 1.18= 157 sacks of cement for fill up. Operator ran 230 sacks of Class A 2% CaCl. Operator broke circulation, mixed cement, ran cement, displaced and locked plug down with 1500psi. No loss of circulation noted during cementing. Cement water was from a municipal water supply, pH 7. Operator placed 7 centralizers on the long string 1 st centralizer was placed on the pup joint then every other joint after that. Operator requested that they be allowed to solidify pits then dig a 2nd pit in the bank were the rig is located and encapsulate drill cutting there. Company was given two options: preferred option is to solidify pits and remove from site. Operator was given contact information to Waste Managements Geneva land fill, the land fill will take PCS waste. 2nd option solidify pits and construct 2nd pit in bank. Operator was informed that current pits do not meet (1501:9-3-08 standards.) Operator excavated pits and built a 4 foot berm to increase the capacity of the pits. Water level was above natural ground level.
1403203582 2014-06-19 UrbanProduction Wells No Violations I inspected this producing unit as part of regular site check and inspection activity. The well was completed on 07/13/2011. Production records are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger lift system. The wellhead is located along the perimeter parking area for the City of Beachwood Maintenance Garage. The wellhead is enclosed in a chain-link fence which is locked. There are no signs of leakage or problems at the wellhead. The aboveground storage tank battery is located north of the wellhead, along the same perimeter area. The battery is comprised of 1 steel 100-barrel production tank, a 25-barrel poly brine tank, and a horizontal separator. The battery is located in a separate chain-link enclosure which is in good condition. The load-out is bull-plugged and locked. The secondary containment at the battery appears is well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery which is in need of maintenance. Process safety equipment is present. The area of the well is generally level with a slight topographic drop to the west. Surface drainage is primarily controlled by engineered storm sewer infrastructure and drain inlets, of which there is one within several feet of the battery. I did not observe any signs of gully formation or washouts. Access to the unit is afforded by general entry into the maintenance garage area, and there is no dedicated access route or roadway. Beyond the area cleared for the wellhead and tank battery, the areas surrounding the unit are comprised of advanced development for commercial use. Numerous multi-tenant commercial and professional offcie buildings are located along Mercantile Drive. I notified Seagull about the need for maintenance on the ID signage.
2108739861 2017-10-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift system and associated tank battery located within the City of Beachwood service garage facility. At the time of this inspection, I observed the following: The load lines were plugged and secure. The load-line valve was now locked. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of asphalt-paved parking and drive areas and fringe grassy portions, and found no signs of impact or degradation attributable to the production system.
493691137 2010-7-13 0:00: UD No Violations
737752179 2013-2-19 0:00: PL No Violations
871744407 2018-1-8 0:00:0 UP No Violations 0.50

For data sources see[9]

References