X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22161

Well Details

Well ID: 34-035-22161
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: PRITCHETT
License Status: Producing
License Date: 2010-04-09
Spud Date: 2010-07-23
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2010-07-28
Well Total Depth: 3738.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.450000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-04-09 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:4/9/2010, Expired Date:4/9/2011 6:00:00 AM, Drilling unit acres:22.4, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-07-28
Completion Report Received 2010-08-26
Construction Permit Expires 2011-04-09
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-10-27 3521 3541 50
3521 3541 50
3521 3541 50

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-08-10 H2O 15 2191 Bbl 60000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 OHIO VALLEY ENERGY SYSTEMS COR 19595.00 0.00 336
2012 OHIO VALLEY ENERGY SYSTEMS COR 24053.00 30.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 29173.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 18164.00 89.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 8036.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 9319.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 6827.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 19664.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 226 336
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 95 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 60 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 65 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 128 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1069082899 2010-7-27 0:00: DD No Violations
-1192111588 2010-7-26 0:00: DD No Violations
-1590005469 2010-7-22 0:00: UD No Violations
-1780159340 2017-10-11 0:00 UP No Violations 1.00
-2008522404 2010-7-24 0:00: UD No Violations
-2013994434 2014-8-18 0:00: UP No Violations
-224743257 2010-7-23 0:00: UD No Violations
-418415170 2010-7-26 0:00: DD No Violations
-504755703 2010-7-22 0:00: UD No Violations
-962128036 2010-7-23 0:00: UD No Violations
-99213477 2010-7-20 0:00: UD No Violations
0099213477 2010-07-20 Urban Drill / Deepen / Reopen No Violations Location made, orange fencing up around site perimeter, and silt fencing up per permit conditions.
0224743257 2010-07-23 Urban Drill / Deepen / Reopen No Violations Conductor cement operation was witnessed. The cement operation and site conditions were acceptable.
0418415170 2010-07-26 Drill / Deepen / Reopen No Violations Drilling on fluid at 1976 no gas encountered in oriskany top at 1946
0504755703 2010-07-22 Urban Drill / Deepen / Reopen No Violations Rig moving onto site.
0633639835 2010-08-20 Drill / Deepen / Reopen No Violations Crew working on site fencing around tank battery and grading site out.
0962128036 2010-07-23 Urban Drill / Deepen / Reopen No Violations Surface casing was cemented. Cement operation and site conditions were satisfactory.
1069082899 2010-07-27 Drill / Deepen / Reopen No Violations Drilling at 2950 no violations.
1170344768 2010-07-29 Drill / Deepen / Reopen No Violations TD reached and running 4.5 casing rigging up to cement casing.
1192111588 2010-07-26 Drill / Deepen / Reopen No Violations drilling at 2750 no violation.
1282586478 2010-07-28 Urban Drill / Deepen / Reopen No Violations Mrs. Veronica Gallo 440-446-0114 called to complain that they are drilling to close to homes at 31371 Cedar Road also she want to make sure the water table is protected . I arrived at site used GPS Checked spacing to home which is due south of well approximately 120.

Checked casing program for what casing was set 72 of 11.75 conductor cemented on 7-23-10 no problem cementing,85/8 casing cemented on 7-23-10 no problems with cementing.

Phone to Mrs. Gallou informed her that the well meets spacing and no problems encounter while cementing of the conductor and surface casing.  

Case#10-007 Case closed:

1322771487 2011-12-01 UrbanProduction Wells No Violations Received complaint from resident 7 doors away of petroleum odor in water when opening spigot on outside of house. Scanned area with gas meter and obtained following readings. O2- 20.6/ LEL - 0/ H2S-0/CH4IR/ CO - 0. Company checked well pressure prior to 12:00 Noon and recorder 1 Lb pressure.
1323186307 2011-12-02 UrbanProduction Wells No Violations Received notification from Norburt Lowder on 12/01/2011 of complaint of petroleum smell coming from outside water spigot when it is turned on. Residence is located at 31107 Cedar Road, Mayfield Heights, Ohio. Residence is located West of the oil and gas well, #34-135-2-2161-00-00. Well and tank battery were inspected, slight gas odor in air detected by smell when entering inside well head area. Used gas meter at waist level and around connections and fittings. The readings from the meter were as follows: O2-0/LEL-0/H2S-0/CH4IR/CO-0. Well head area and tank battery were inspected by the inspectors on site. Well is in compliance with 1501:9-9-05
1351660189 2010-11-23 Preliminary Restoration No Violations
1590005469 2010-07-22 Urban Drill / Deepen / Reopen No Violations The drilling contractor was rigging up on the location. MRI 2 Norburt Lowder was on location, also. Conditions were acceptable.
1780159340 2017-10-11 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located in the back of a residential property. At the time of this inspection, I observed the following: The enclosure gates were locked. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems with the following exception: I noted a minor leakage of gas from the 4.5-inch casing threads. I notified Don Nething of Ohio Valley Energy about the leak. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The surrounding, shared-use, drive areas were in good condition.
2008522404 2010-07-24 Urban Drill / Deepen / Reopen No Violations BOP test passed
2013994434 2014-08-18 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 07/28/2010. The unit is producing and production reports are current. The producing unit is accessed via a dedicated, gravel-paved access road which extends north from the terminus of the current residential driveway. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 100-barrel production tank, 1 25-barrel poly brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. I observed no issues or problems requiring attention at the time of my inspection.
633639835 2010-8-20 0:00: DD No Violations

For data sources see[9]

References