Well Details

Well ID: 34-035-22154
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: EOS ENERGY LLC
Well Pad ID:
Farm/Lease Name: KMIECK
License Status: Producing
License Date: 2010-03-31
Spud Date: 2010-04-25
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2010-05-01
Well Total Depth: 3769.00 ft
Configuration: Directional
Latitude: 41.330000
Longitude: -81.710000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-03-31 Proposed Formations:OHIO SHALE/THRU CLINTON, Issued Date:3/31/2010, Expired Date:3/31/2011 6:00:00 AM, Drilling unit acres:27.46, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-05-01
Correction to Well 2010-07-16 CORRECTION TO TARGET INFORMATION (FROM AS DRILLED SURVEY)--TARGET LOCATION= 3100'SL & 2319'WL OF SEC. 19; TARGET X= 2,215,226 AND TARGET Y= 606,906.
Completion Report Received 2010-09-22
Construction Permit Expires 2011-03-31
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-11-24 3534 3572 79
3534 3572 79
3534 3572 79

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 89695 Gal 60000 244M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 CUTTER OIL COMPANY 9478.00 3197.00 224
2011 CUTTER OIL COMPANY 31798.00 3704.00 365
2012 CUTTER OIL COMPANY 28603.00 2034.00 366
2013 CUTTER OIL COMPANY 12728.00 947.00 365
2014 CUTTER OIL COMPANY 6790.00 637.00 365
2015 CUTTER OIL COMPANY 5045.00 287.00 365
2016 CUTTER OIL COMPANY 4019.00 304.00 365
2017 CUTTER OIL COMPANY 3160.00 432.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 CUTTER OIL COMPANY Brine 3148 224
2011 CUTTER OIL COMPANY Brine 714 365
2012 CUTTER OIL COMPANY Brine 516 366
2013 CUTTER OIL COMPANY Brine 335 365
2014 CUTTER OIL COMPANY Brine 204 365
2015 CUTTER OIL COMPANY Brine 219 365
2016 CUTTER OIL COMPANY Brine 140 365
2017 CUTTER OIL COMPANY Brine 134 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1164417317 2010-4-26 0:00: DD No Violations
-162822518 2016-6-2 0:00:0 UP No Violations 1.00
-247729056 2010-5-9 0:00:0 UD No Violations
-447189615 2015-6-25 0:00: UP No Violations
-620113744 2015-1-29 0:00: UP No Violations 0.50
-637651399 2013-10-28 0:00 UP No Violations
-696343865 2019-4-30 0:00: PW No Violations
-848028202 2017-4-28 0:00: UP No Violations 0.50
0162822518 2016-06-02 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, fittings and connections were secure at the wellhead pump jack system. The surface casing nipple was gauged and showing 50 PSI and is plumbed into the production system. The electrical box at the well enclosure was locked and secure. There was secondary containment at the wellhead and battery which were intact and dry. The wellhead and battery enclosure gates were locked and secure. The load-line valves were locked. Fittings and connections within the battery system were secure. Tank lids were closed and sealed. Signage is present and accurate. I walked the areas surrounding the wellhead and battery, which are comprised of wooded areas and wild vegetation. I did not observe any signs or evidence of problems or impacts. The access road is comprised of a shared-use residential driveway which extends south an additional 300 feet to the well and battery, and was dry and in good condition.
0247729056 2010-05-09 Urban Drill / Deepen / Reopen No Violations cemented 4.5 casing
0323152692 2010-04-26 Drill / Deepen / Reopen No Violations Rig moving on to location.
0447189615 2015-06-25 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous Compliance Notice. Load lines are now lock-protected. Tank lids are sealed and secure. Electrical boxes are locked and secure. Process safety gear, including spark arrestor is present. Secondary containment at the well and battery are intact. The dike drain is secure. Update of signage is in progress.
0620113744 2015-01-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead pump jack system enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the wellhead and battery are via a dedicated access road which has been plowed and is passable. Valves and connections at the battery are secure. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection.
0637651399 2013-10-28 UrbanProduction Wells No Violations The producing unit consists of a wellhead with pump jack and above-ground storage tank (AST) battery. The battery is comprised of 2 140-barrel steel production tanks, 1 50-barrel brine tank and separator unit. Both the wellhead and battery are enclosed in separate board-on-board fences. The gates and load-outs are locked. ID placard and secondary containment are good. Process safety gear (spark arrestor, low-pressure relief valve, carbon filter) is present. No problems noted.
0648709765 2011-09-07 UrbanProduction Wells No Violations Urban well status check. No violations found. Well is in compliance.
0696343865 2019-04-30 Production Wells No Violations I conducted an inspection of the well and found no violation at well or tank battery.

The following maintenance issues need to be repaired: Gaps between the top of the dike and bottom of the board on broad fencing around the dike. I contacted Ed Cutright (contractor pumper) and he stated it will be put on the repair schedule.

0848028202 2017-04-28 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead pump-jack system and associated tank battery in separate board-on-board enclosures located at the rear portion of a larger, residential parcel. I found the enclosure gates to be locked and secure. The load-line valves were locked and secure. Fittings and connections within the wellhead and battery systems were secure and free from problems. There was secondary containment which was intact and dry. The access road is partially-shared with the residence and then extends 300 feet to the south, and gravel-paved. The access road was in good condition.
0925920676 2010-08-04 Preliminary Restoration No Violations
1164417317 2010-04-26 Drill / Deepen / Reopen No Violations cementing conductor.
1190414119 2018-10-18 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection and evaluation of current condition following recent change in ownership. At the time of this inspection, I noted the following:. the well was in active production. The enclosure gates were locked and secure. The identification was current and accurate. The load-line valves were plugged and locked. Tank lids were closed and sealed. I walked the areas surrounding the well and battery and found no signs of problems or indications of impact.
1229460610 2010-04-27 Drill / Deepen / Reopen No Violations cementing casing 85/8.
1600298684 2015-05-07 UrbanProduction Wells Violations Noted I was on site to conduct a status check on this well with DOGRM Inspector - John Fleming and District Manager - Rick Anderson. The wellhead is equipped with pumpjack and the valves on the wellhead are open. Identification signs are present on the tank battery and wellhead fences, but are not urban rule compliant. There is oil leaking from the stuffing box. The tank battery consisted of 2-140 BBL production tanks, mechanical separators, and a 1500 gallon poly brine tank. The production tank sealable hatches are not secured properly. The vent stacks are equipped with pressure relief valves but no lightning arrestors. There is a charcoal filter. The tank pick-up line valves have flat plugs but are not locked and the locks were hanging on the catwalk brackets on the tanks. The pick-up lines are not locked. The wellhead and tank battery were fenced with an 8-foot board-on-board fencing, and the man doors were locked. The lease road is stable and drivable. The following needs completed by:

1) Clean-up all spilled oil/brine in tank battery (6-16-15) 2) Insert plugs/or add locks into the tank valves and pick-up lines (6-16-15) 3) Install lightning arrestors on vent stacks (6-16-15) 4) Add additional identification sign information as required by 1501:9-9-

1712360700 2020-7-8 0:00:0 UP No Violations 0.50
1760745088 2010-04-27 Drill / Deepen / Reopen No Violations BOP test . Passed
323152692 2010-4-26 0:00: DD No Violations
648709765 2011-9-7 0:00:0 UP No Violations
925920676 2010-8-4 0:00:0 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1600298684 US-OH-115681 2015-06-08 LOCKS
1600298684 US-OH-115682 2015-06-08 TANKS (a-i)
1600298684 US-OH-115683 2015-06-08 Well operation causing pollution and contamination

For data sources see[9]